Purpose. To analyze retrospectively the clinical efficacy and safety for patients treated with fractionated stereotactic radiation therapy (FSRT) using volumetric modulated arc therapy. Methods. Between 2016 and 2017, 46 patients with solitary brain metastasis who underwent FSRT consisting of 25‐40 Gy/5 fractions were recruited in this study. All targets within the same course received different prescriptions according to size. Toxicities were graded according to the Common Terminology Criteria for Adverse Events version 4.0. Results. The median follow‐up was 11 months (3‐53 months). The 6‐month and 12‐month local control rate calculated by Kaplan‐Meier estimate was, respectively, 95% and 86%. Tumor diameter < 2.5 cm obtained 100% improved 12‐month local control rate compared with 66% in those with ≥2.5 cm (P < 0.001). The 12‐month local control calculated by Kaplan‐Meier estimate was 95% in tumors with >30 Gy treatment and only 60% in tumors with ≤30 Gy treatment (P = 0.001). Multivariate analysis revealed that the prescription dose ≤ 30 Gy resulted in increased local failure (hazard ratio (HR), 0.14 (range, 0.019‐0.95; P = .046)). Grade 3 or worse toxic effects were found in 5 (11%) patients, and no patient experienced surgical resection for symptomatic radioactive necrosis. Conclusions. FSRT for solid brain metastasis appears to have the advantages of a high rate of local control with a minimal risk of severe toxicity and deserves application in the clinical practice.
14 June 2021 in Journal of Clinical Laboratory Analysis
Background: The abnormal increase in serum IgG4 level is an important clinical symptom of IgG4‐related disease (IgG4‐RD), and the detection of serum IgG4 level is a powerful tool for the diagnosis of IgG4‐RD. This study was conducted to establish a simple and rapid immunoassay for the determination of human serum IgG4 levels.Methods: Based on the competition method, a novel immunoassay was established for the determination of human serum IgG4 using a combination of time‐resolved fluoroimmunoassay (TRFIA) and magnetic microspheres. IgG4 was coupled with magnetic microspheres and competed with IgG4 in the samples to bind the Eu3+‐labeled anti‐IgG4 antibody. The immunocomplex was separated and washed in a magnetic field, and the fluorescence counts were measured according to the number of dissociated europium ions.Results: The analytical sensitivity of IgG4‐TRFIA based on magnetic microspheres was 0.006 g/L, and the detection range was 0.006–20 g/L under optimal conditions. The precision, recovery, and specificity of this immunoassay were demonstrated to be acceptable. The clinical application of IgG4‐TRFIA based on magnetic microspheres was evaluated and compared with that of immunonephelometry. The results showed that the two detection methods had a good correlation, with a correlation coefficient of .9871.Conclusion: IgG4‐TRFIA based on magnetic microspheres has the advantages of high sensitivity, wide detection range, and short analysis time and has the potential to become a useful tool for the diagnosis of IgG4‐RD.