Qun Yu

Dr. Qun Yu


Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1994 in Vehicle System Dynamics
Verified
Journal Article
Closed access
GXGu Xi
Gu Xi
QYQun Yu
Qun Yu
The safety of vehicles has become the main concern of vehicle designers. Many researchers developed sophisticated mathematical models of vehicles to achieve maximum safety in vehicle design. Later it has been known that this models can't be utilized widely in the simulation of transient manoeuvres because the performance of transient manoeuvres mainly depends on drivers. To solve this problem, It is necessary to study the driver—vehicle—environment closed—loop system. In this paper, a new mathematical model using fuzzy control theory for driver—vehicle—environment system of handling and stability is developed. The research efforts are mainly on the mathematical model of three degrees of freedom of a vehicle, on the method of establishing a driver fuzzy control model, on the computer simulation of driver—vehicle—environment system and on the comparison of simulation results with running experiment results. A block diagram for the driver—vehicle—environment system used in this study is shown in Fig. 1. This study is applicable to describe transient manoeuvres of vehicles and evaluate vehicle handling characteristics.

1 November 2018
Verified
Conference Paper
Closed access
NCNa Cao
Na Cao
TGTonghui Ge
Tonghui Ge
QYQun Yu
Qun Yu
There are differences in the electromagnetic transient characteristics between the wind power access system and the traditional power grid during the fault, resulting in the problem of adaptability deterioration of the relay protection equipment in the wind power access system. In the PSCAD simulation platform, the adaptability of the traditional transformer protection in the wind field is further analyzed. When the fault occurs in the transformer zone, the differential protection cannot be quickly and stably operated, the transition impedance causes the protection to be rejected, and the traditional transformer protection does not adapt to the wind power access system. Based on the analysis of the characteristics of the doubly-fed wind farm and the system fault transient current frequency, the transformer protection based on the difference of current frequency is proposed, and the action criterion is constructed by using the difference of instantaneous frequency. The simulation results show that the protection method can reliably and sensitively identify various types of short-circuit faults inside and outside the transformer, adapt to different wind speeds, and withstand the ability of transition resistance.

29 August 2020 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
QYQun Yu
Qun Yu
NCNa Cao
Na Cao
QLQilin Liu
Qilin Liu
YQYuqing Qu
Yuqing Qu
YZYumin Zhang
Yumin Zhang
This paper proposes effective evidence on the correlation between trend and self-organized criticality (SOC) of the power outage sequence in China. Taking the data series of blackouts from 1981 to 2014 in the China power grid as the research object, the method of is introduced into the analysis of the power system blackout sequence to demonstrate their prominent long-time correlations. It also verifies the probability distribution of load loss about blackout size in the China power grid has a tail feature, which shows that the time series of blackouts in the China power grid is consistent with SOC. Meanwhile, a kind of mathematical statistics analysis is presented to prove that there is a seasonal trend of blackouts, and the blackout frequency and blackout size have not decreased over time but have an upward trend in the China power grid, thereby indicating that blackout risk may be increasing with time. The last 34 years’ data samples of power failure accidents in the China power grid are used to test the proposed method, and the numerical results show that the proposed self-organized criticality and trend analysis method can pave the way for further exploration of the mechanism of power failure in the China power grid.

1 October 2006
Verified
Conference Paper
Closed access
QYQun Yu
Qun Yu
GJGuo Jianbo
Guo Jianbo
The state electric power transmission networks of china is experiencing rapid changes and will continue to be operated closer to a stressed condition in which there is substantial risk of cascading outages and blackouts. Major cascading disturbances, or blackouts of these transmission systems can obviously cause severe damage to our society. Based on the concept of self-organized criticality (SOC) and fractal and by analyzing power system blackouts in China from 1981 to 2002, the characters of SOC of domestic power system blackouts are revealed, and the scale-frequency models for blackouts occurred in nationwide power grid are constructed. For these statistics, it strongly suggests that SOC dynamics may play an important role in the global complex dynamics of power systems.

2 March 2026 in Energies
Verified
Journal Article
Open access
PDF file
QYQun Yu
Qun Yu
Zhiyi ZhouZhiyi Zhou
Zhiyi Zhou
JTJin Tongshuai
Jin Tongshuai
WSWeimin Sun
Weimin Sun
YJYan Jiongcheng
Yan Jiongcheng
With the intensification of climate change, deepening energy transition, and increasing social vulnerability, extreme power outage events pose escalating challenges to the governance capacity of modern power systems. Existing evaluation frameworks primarily focus on engineering reliability and economic loss estimation, lacking systematic quantification of the governance complexity arising from multidimensional interacting pressures behind outage events. This creates a blind spot in both theoretical research and governance practice, hindering differentiated resilience decision-making. To address this gap, this study develops a four-dimensional evaluation framework of power outage governance complexity encompassing event attributes, external environment, internal system, and social impacts. Based on county-level outage data and multi-source auxiliary data in the United States from 2015 to 2024 and employing the XGBoost–SHAP interpretable machine learning approach, we construct the Power Outage Complexity Index (POCI) for all U.S. counties and systematically analyze its spatiotemporal evolution and core driving factors. The results show that outage governance complexity in the U.S. power grid exhibits a significant upward trend during 2015–2024, with an average annual growth rate of 1.84%. Spatially, significant positive autocorrelation is observed, and 146 high-complexity hotspot counties are identified, mainly clustered along the East and West Coasts, the Gulf Coast, and the Southwest. Driver analysis reveals that social impact and event attribute dimensions together account for nearly 90% of the variance in complexity, with cumulative outage exposure burden, outage frequency, and large-scale event ratio being the most critical drivers. Theoretically, this study extends power resilience research from an engineering-physical paradigm to a socio-technical governance paradigm and provides a reproducible methodological framework for assessing governance complexity in critical infrastructure systems. Practically, the POCI can serve as a governance diagnostic tool for the power industry and regulators, supporting resilience investment prioritization, emergency resource optimization, and differentiated governance strategy formulation. It also provides empirical evidence for safeguarding energy security in highly vulnerable communities and promoting energy resilience equity.

1 January 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
YWYuefei Wu
Yuefei Wu
NCNa Cao
Na Cao
QYQun Yu
Qun Yu
In order to quickly and effectively distinguish the operating state of the circuit breaker and improve the accuracy of the state evaluation, an improved fuzzy comprehensive evaluation model is proposed. The evaluation index is weighted based on the combined weighting method, which avoids the dependence of the traditional analytic hierarchy process on the subjective scoring of the weights. The gray correlation theory is introduced to modify the evaluation results, which effectively overcomes the inherent shortcomings of the principle of maximum membership. The improved fuzzy comprehensive evaluation method is applied to the state evaluation of circuit breakers, and the evaluation indexes are established through time parameters, speed parameters, circuit parameters and electrical characteristic parameters, and then a multi-layer fuzzy comprehensive evaluation model is established. Finally, the evaluation model is used to analyze the laboratory circuit breaker, which verifies the feasibility and effectiveness of the model.