Jasur Tursunqulov

Dr. Jasur Tursunqulov


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in International Journal of Analytical Chemistry
Verified
Journal Article
Open access
GKGulnora Karabayeva
Gulnora Karabayeva
NQNigora Xakimovna Qutlimurotova
Nigora Xakimovna Qutlimurotova
ZYZukhra Yakhshieva
Zukhra Yakhshieva
RQRukhiya Qutlimurotova
Rukhiya Qutlimurotova
NANargiza Atakulova
Nargiza Atakulova
JTJasur Tursunqulov
Jasur Tursunqulov
The demand for cobalt‐based alloys has been steadily increasing due to advancements in industrial and cutting‐edge technologies, particularly in metallurgy, where cobalt plays a crucial role in high‐performance superalloys, battery production, and corrosion‐resistant materials. Consequently, the concentration of cobalt ions in wastewater and environmental samples has exceeded permissible levels, raising significant ecological concerns. This study presents the development of an efficient method for the determination of cobalt(II) ions using a silver/mercury film working electrode (Hg(Ag)FE) modified with the organic dye ortho-nitrosophenol (o‐NF) through cyclic voltammetry (CV). Optimization of the experimental conditions revealed that an acetate buffer (0.1 M, pH 5.1) served as the supporting electrolyte, with an accumulation time of 10 s and a concentration of 2.0 μM o‐nitrosophenol. The preconcentration conditions were adjusted to enhance the sensitivity and selectivity for cobalt(II) ion detection. The method exhibited a linear relationship in the concentration range of 0.040–0.160 μM ( R 2 = 0.9863), with a limit of detection (LOD) of 0.010 μM and a limit of quantification (LOQ) of 0.034 μM for Co(II) ions. The proposed method was successfully applied to the analysis of water samples from the Aydar–Arnasoy Reservoir, and the accuracy of the results was statistically validated using Student’s t ‐test. These findings demonstrate the potential of the developed method as an effective tool for environmental monitoring and the determination of cobalt ions in ecological protection initiatives.

25 September 2026 in Nano Trends
Verified
Journal Article
Open access
ZAZaman Abdalhussein Ibadi Alaridhee
Zaman Abdalhussein Ibadi Alaridhee
GAGafur Abdulakimov
Gafur Abdulakimov
ASAseel Smerat
Aseel Smerat
DKDilafruz Kholmurodova
Dilafruz Kholmurodova
KBKhasan Berdimuradov
Khasan Berdimuradov
RAReza Azimi
Reza Azimi

24 June 2025 in Chemical Papers
Verified
Journal Article
Closed access
PDF file
SRSurayyo Razzoqova
Surayyo Razzoqova
SKShakhnoza Kadirova
Shakhnoza Kadirova
ZYZuxra Yaxshiyeva
Zuxra Yaxshiyeva
JAJamshid M. Ashurov
Jamshid M. Ashurov
BKBakhrom Khusanov
Bakhrom Khusanov
JTJasur Tursunqulov
Jasur Tursunqulov

1 July 2026 in Electrochem
Verified
Journal Article
Open access
PDF file
SRShaxnoza Rustam qizi Rajabova
Shaxnoza Rustam qizi Rajabova
NQNigora Xakimovna Qutlimurotova
Nigora Xakimovna Qutlimurotova
JTJasur Tursunqulov
Jasur Tursunqulov
RKRukhiya Kutlimurotova
Rukhiya Kutlimurotova
Paracetamol (PA) ranks among the most frequently prescribed over-the-counter analgesic and antipyretic agents worldwide; nonetheless, overdose scenarios are associated with severe hepatotoxic and nephrotoxic consequences, while its incomplete metabolic removal renders it a persistent micropollutant in surface and wastewater systems. These concerns underscore the urgent need for rapid, cost-efficient, and highly sensitive analytical tools capable of quantifying PA at trace levels in complex matrices. In the present study, spherical gold nanoparticles (AuNPs) were fabricated through an environmentally benign route exploiting an aqueous extract of Juniperus sp. leaves as the reducing and capping agent, with polyvinylpyrrolidone (PVP) serving as an additional colloidal stabilizer. The resulting nanoparticles were immobilized on a glassy carbon electrode to construct an AuNPs/PVP/GCE sensing platform. Physicochemical characterization by UV–Vis spectroscopy, dynamic light scattering (DLS), and transmission electron microscopy (TEM) verified the spherical morphology, narrow size distribution, and colloidal stability of the synthesized AuNPs, and further confirmed a 3.5-fold enlargement of the electroactive surface area relative to the unmodified electrode. Under fully optimized conditions, the fabricated sensor delivered a well-defined linear voltammetric response toward PA oxidation across the concentration interval of 0.05–0.31 µM (R2 = 0.9939), with a limit of detection of 0.024 µM and a limit of quantification of 0.080 µM. The sensor retained its analytical accuracy in the presence of common co-existing species, including ascorbic acid, uric acid, dopamine, caffeine, ibuprofen, and adrenaline. Quantitative determination of PA in commercial tablet formulations via the standard addition approach yielded results in close agreement with the declared content, confirming the practical suitability of the AuNPs/PVP/GCE platform for routine pharmaceutical quality control.

1 August 2026 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
JAJohn Oluwafemi Ayoola
John Oluwafemi Ayoola
BABabatunde Oluseyi Ajiboye
Babatunde Oluseyi Ajiboye
AOAbraham Olanrewaju Opanike
Abraham Olanrewaju Opanike
FAFahim Arshad
Fahim Arshad
SHShiekh Marifatul Haq
Shiekh Marifatul Haq
XMXurshidbek Mirzakamol o'g'li Mamatov
Xurshidbek Mirzakamol o'g'li Mamatov

14 September 2026 in New Journal of Chemistry
Verified
Journal Article
Closed access
ZAZaman Abdalhussein Ibadi Alaridhee
Zaman Abdalhussein Ibadi Alaridhee
GAGafur Abdulakimov
Gafur Abdulakimov
ASAseel Smerat
Aseel Smerat
DKDilafruz Kholmurodova
Dilafruz Kholmurodova
KBKhasan Berdimuradov
Khasan Berdimuradov
KOKhasanov Okhunjon
Khasanov Okhunjon
A sustainable MISCOF@Cu/GCE electrode enables efficient, room-temperature electro-carbonylation for N -phenylcinnamamide synthesis 4(a–l) . This multifunctional platform acts as a catalyst and electrolyte, achieving 91–98% yields over 10 cycles.