Urkiye Akar Tarim

Dr. Urkiye Akar Tarim


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2012 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
UTUrkiye Akar Tarim
Urkiye Akar Tarim
EOE. N. Ozmutlu
E. N. Ozmutlu
OGO. Gurler
O. Gurler
SYS. Yalcin
S. Yalcin

1 December 2018 in Sakarya University Journal of Science
Verified
Journal Article
Open access
PDF file
UTUrkiye Akar Tarim
Urkiye Akar Tarim
OGOrhan Gürler
Orhan Gürler
This work aims to introduce an useful computational model, based in Monte Carlo simulation, which can be used in practical application, and this paper presents values determined using a Monte Carlo algorithm for linear attenuation coefficient of lead zinc borate glasses with different percentages of PbO. The simulation results have been verified with predictions from the XCOM program in the studied energy region from 1 keV to 2000 keV and experimental results. Thus, this verification indicated that this research method can be followed to determine the interaction and attenuation of gamma rays with the several energies in different materials. Also, the values of mean free path and the half-value layer were calculated using the values of the linear attenuation coefficient. The dependence of these radiation shielding parameters on the energy of impinging gamma ray and the ratio of substances changes has been examined.

23 June 2020 in Iranian Journal of Science and Technology, Transactions A: Science
Verified
Journal Article
Closed access
PDF file
OGOrhan Gurler
Orhan Gurler
ZTZeynal Tumsavas
Zeynal Tumsavas
UTUrkiye Akar Tarim
Urkiye Akar Tarim

3 March 2023 in Radiation Effects and Defects in Solids
Verified
Journal Article
Closed access
UTUrkiye Akar Tarim
Urkiye Akar Tarim
OGOrhan Gurler
Orhan Gurler
LKLatif Korkmaz
Latif Korkmaz
The study aimed to present an alternative method that is applicable to develop the perfect tissue-equivalent material that is completely tissue equivalent in all of its gamma-ray interaction properties. In this work, a Monte Carlo code has been written and simulations have been performed to achieve the gamma-ray interaction data details for the selected body tissues and tissue substitutes quoted from the ICRU Reports that are required for accurate assessment in radiotherapy, radiodiagnosis patient dosimetry and radiation protection. Accurate values of the linear attenuation coefficient for the selected absorber samples have been calculated by using simulation outputs. A comparison has been made with theoretical and experimental data that has appeared in the literature. The results presented in the tables, appear to be close to each other, which shows that the simulation procedure used in this work is suitable for use in such kinds of studies. The results reported here imply that the method presented in this study is important and reliable in providing convenient substitutes for certain treatment procedures for phantoms, radiation detectors, detector walls and tissue-equivalent proportional counters.

28 February 2023 in Sakarya University Journal of Science
Verified
Journal Article
Open access
PDF file
UTUrkiye Akar Tarim
Urkiye Akar Tarim
Considering the negative effects on the environment and toxicity of lead, which has been widely used for gamma shielding for a long time in nuclear technology, studies have been focused on the development of various materials that can be used as an alternative to lead in gamma radiation shielding. In this research, a composite material containing magnetite and boron carbide (epoxy/magnetite/boron carbide) and gamma transmission technique which is emphasized in nuclear applications have been used for the study of gamma ray shielding. The radiation sources considered for this technique are the radioisotopes Am-241, Cs-137, Na-22 and Co-60, which are important in nuclear technology. The interactions between the composite material and gammas with 59.5, 511, 661.6, 1173.2, 1274.5 and 1332.5 keV energies were investigated separately by the Monte Carlo method, and the ability of the material to shield the radiations at these energies was investigated. Gamma rays, one by one, followed by using cross sections and determining the probability of interaction with the composite from the point they are emitted until they leave the system (through escaping or absorption from the system) in the Monte Carlo code, which is written to determine the linear attenuation coefficient, mean free path, half value layer and tenth value layer, among the radiation shielding parameters of the composite under investigation. The shielding parameters calculated using the simulation results were also calculated using the data obtained from the XCOM software, and the results were found to be compatible with each other. On the other hand, in order to better evaluate the usability of the composite as an alternative shielding material for nuclear applications in the studied energy range, a comparison was made with the shielding parameters of various materials available in the literature.

17 September 2021 in Radiation Effects and Defects in Solids
Verified
Journal Article
Closed access
SYSezai Yalcin
Sezai Yalcin
UTUrkiye Akar Tarim
Urkiye Akar Tarim
OGOrhan Gurler
Orhan Gurler
OGOzcan Gundogdu
Ozcan Gundogdu
DBDAVID BRADLEY
DAVID BRADLEY
The present work, with its interest focusing on the elastic scattering of energetic electrons, provides a novel formulation that is demonstrated to give accurate values of the screening parameter. This is a matter considered vital in obtaining transport cross-sections, the work herein covering not only a wide range of electron energies popular in applications (1–3000 keV) but also a comprehensively wide range of target atomic numbers (Z: 1–94). Such ability has hitherto not been commonly available in making use of existing formulations. Results from the proposed formula together with comparisons made against previously published results are presented for seventeen representative elements, covering the energy range 1 keV to 3 MeV, providing a representative condensation from the 94 elements for which we have made comparable calculations. The new formulation is seen to offer a viable and accurate approximation, being both simple to apply and devoid of limitations within the bracketed electron energy and target atomic number ranges.