We present in this paper an algorithm of filtering the noisy real ECG signal. The classical wavelet denoising process, based on the Donoho et al. algorithm, at the 4 th level, appears clearly the P and T waves whereas the R waves undergo considerable distortion. This is due to the interference of the WGN and the free noise ECG detail sequences at level 4. To overcome this drawback, our key idea is to estimate the corrupted WGN and consequently remove the noise interfering R waves at the 4 th level detail sequence. Our denoising algorithm was applied to a set of the MIT-BIH arrhythmia database ECG records corrupted with a 0 dB WGN which provided an output SNR of around 6 dB and an MSE value of around 0.0011. A comparative analysis using the low pass Butterworth filter and the 4 th level classical wavelet denoising provides the output SNR values of around 3 dB and MSE value of around 0.0018; which demonstrates the superior performance of our proposed denoising algorithm
12 August 2013 in Journal of Physics: Conference Series
We present in this work an algorithm for electrocardiogram (ECG) signal compression aimed to its transmission via telecommunication channel. Basically, the proposed ECG compression algorithm is articulated on the use of wavelet transform, leading to low/high frequency components separation, high order statistics based thresholding, using level adjusted kurtosis value, to denoise the ECG signal, and next a linear predictive coding filter is applied to the wavelet coefficients producing a lower variance signal. This latter one will be coded using the Huffman encoding yielding an optimal coding length in terms of average value of bits per sample. At the receiver end point, with the assumption of an ideal communication channel, the inverse processes are carried out namely the Huffman decoding, inverse linear predictive coding filter and inverse discrete wavelet transform leading to the estimated version of the ECG signal. The proposed ECG compression algorithm is tested upon a set of ECG records extracted from the MIT-BIH Arrhythmia Data Base including different cardiac anomalies as well as the normal ECG signal. The obtained results are evaluated in terms of compression ratio and mean square error which are, respectively, around 1:8 and 7%. Besides the numerical evaluation, the visual perception demonstrates the high quality of ECG signal restitution where the different ECG waves are recovered correctly.
A new method of signal compression, called Quantized Run Length Encoding QRLE, based upon the ‘classical’ run length method combined to discrete wavelet transform thresholding planned for a transmission via the WiFi IEEE 802.11b WLAN channel, simulated by Simulink/Matlab Integrated Development Environment IDE, is presented in this work. The key idea of our new method consists of quantifying each pair of zero followed by its corresponding run number, issued from the RLE, by one value consisting on the run number value plus an offset of predetermined integer value. In this work, the suitable offset was adjusted to 1024(≡2 10 ). This leads to quantizing the ‘new’ run number on 11 bits while the non null ECG thresholded ECG signal samples are quantized on 10 bits. The trivial advantage of this method is suppression, and consequently gaining, of all zeros. We have applied the proposed algorithm to extracted ECG signals, from the universal MIT-BIH arrhythmia data base. To evaluate the performance of the new QRLE compression method, we have simulated transmitting the compressed ECG signal via the Simulink/Maltab IEEE 802.11b WLAN noisy channel model. Besides the perceptible visual inspection, three criteria are used, in our evaluation phase, that are: compression ratio –CR-, the normalized root mean squared error (NRMSE), and the difference between the original and reconstructed versions of the ECG signal. The obtained results are around 10:1 in terms of CR, 0.07 in terms of NRMSE and a difference of about (10 −4 ) ± 0.02. Moreover, a comparative study with respect to selected ECG compression algorithms show the higher performance of the developed new technique called ‘Quantized run length encoding QRLE’.
The misuse of frequency bands leads to a spectrum shortage. The cognitive radio appears as a natural solution to this problem. A good exploitation of the frequency spectrum starts with a good detection through various techniques, each with its advantages and limitations. In this paper we worked on improving the accuracy of spectrum sensing by developing a new cnn model and the transfer learning of data, also we used the automatic modulation recognition technique to insure the previous knowledge of data witch helped in improving the quality of detection and the performance of the cnn model. our method is based on three aspects entitled aspect1, aspect2 and aspect3. In aspect1 we trained the model to preform the modulation recognition with 11 classes. In aspect2 the model was trained with tow classes an performed the spectrum sensing. In aspect 3 we used the pre-trained model from aspect1 to perform the spectrum sensing with data from aspect2.We trained the model with many types of signals from the dataset RadioML2016.10a as well as noise data that we generated. We also use transfer learning strategies to improve the performance of the sensing model. The results show that we were able to achieve maximum accuracy of 97.22% for the sensing and 99 % for the modulation classification as best accuracy which is very competitive and better than many other proposed techniques.