Nasiq Hasan

Dr. Nasiq Hasan


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
ERElham Rahmanipour
Elham Rahmanipour
NHNasiq Hasan
Nasiq Hasan
AGAdarsh Gadari
Adarsh Gadari
JWJames Whitley
James Whitley
SSSoumya Rhea Sharma
Soumya Rhea Sharma
Jay ChhablaniJay Chhablani
Jay Chhablani
Background/Objectives: To evaluate the challenges and limitations of a deep learning model for automated choroidal boundary detection in eyes with geographic atrophy (GA) using spectral-domain OCT (SD-OCT), and to assess the workflow efficiency of an AI-assisted manual verification approach. Methods: In this retrospective study, total 5723 scans (Heidelberg Spectralis) with GA were analyzed. A previously validated tool (NMI ChoroidAI) was used to segment the choroidal inner (CIB) and outer (COB) boundaries. We compared the “AI-assisted” workflow (automated segmentation followed by manual verification) against “manual segmentation only” in terms of accuracy and time consumption. Slice-wise boundary errors were graded as 0 (accurate), 1 (≤33% deviation), 2 (33–66% deviation), or 3 (>66% deviation). Outcomes included error rates and weighted F1 score (and precision where applicable). Total time for manual-only segmentation versus AI-assisted verification was recorded. -Interreader variability was assessed between the two readers using intraclass correlation coefficient. Results: For CIB, only 5.2% of B-scans showed any deviation (strictly accurate in 94.8%), with weighted F1 score 0.97 and precision 1.00. COB was more error-prone: 19.0% of B-scans showed deviation; however, when minor deviations were considered acceptable, COB acceptability increased to 94.2% (i.e., 5.8% remained >33% deviated). Only 13.2% of B-scans required minor manual correction. For a 97-scan volume, processing time decreased from an average of 7 h (manual only) to 45 min (AI + human verification), an approximate 90% reduction in manual effort. Inter-reader agreement was high (ICC 0.923 for CIB and 0.938 for COB). Conclusions: Although the deep learning model exhibits limitations in COB detection due to artifacts, it serves as a valuable assistive tool. Our model substantially reduces human effort, but mandatory human verification is required to correct boundary errors caused by hyper-transmission before use in clinical trials.

29 January 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
ERElham Rahmanipour
Elham Rahmanipour
NHNasiq Hasan
Nasiq Hasan
AGAdarsh Gadari
Adarsh Gadari
JWJames Whitley
James Whitley
SSSoumya Rhea Sharma
Soumya Rhea Sharma
Jay ChhablaniJay Chhablani
Jay Chhablani
Background/Objectives: To evaluate the challenges and limitations of a deep learning model for automated choroidal boundary detection in eyes with geographic atrophy (GA) using Spectral-Domain OCT (SD-OCT), and to assess the workflow efficiency of an AI-assisted manual verification approach. Methods: In this retrospective study, total 5,723 scans (Heidelberg Spectralis) with GA were analyzed. A previously validated tool (NMI ChoroidAI) was used to segment the choroidal inner (CIB) and outer (COB) boundaries. We compared the "AI-assisted" workflow (automated segmentation followed by manual verification) against "manual segmentation only" in terms of accuracy and time consumption. Slice-wise boundary errors were graded as 0 (accurate), 1 (≤33% deviation), 2 (33–66% deviation), or 3 (>66% deviation). Outcomes included error rates and weighted F₁-score (and precision where applicable). Total time for manual-only segmentation versus AI-assisted verification was recorded .Inter-reader variability was assessed between the two readers using intraclass correlation coefficient. Results: For CIB, only 5.2% of B-scans showed any deviation (strictly accurate in 94.8%), with weighted F₁-score 0.97 and precision 1.00. COB was more error-prone: 19.0% of B-scans showed deviation, however, when minor deviations were considered acceptable, COB acceptability increased to 94.2% (i.e., 5.8% remained >33% deviated). Only 13.2% of B-scans required minor manual correction. For a 97-scan volume, processing time decreased from an average of 7 hours (manual only) to 45 minutes (AI + human verification), an approximate 90% reduction in manual effort. Inter-reader agreement was high (ICC 0.923 for CIB and 0.938 for COB). Conclusions: Although the deep learning model exhibits limitations in COB detection due to artifacts, it serves as a valuable assistive tool. Our model substantially reduces human effort, but mandatory human verification is required to correct boundary errors caused by hyper-transmission before use in clinical trials.