Four-dimensional visualization, i.e., three-dimensional space plus time, of fluid flow and its interactions in geological materials using positron emission tomography (PET) requires suitable radiotracers that exhibit the desired physicochemical interactions. 76Br is a likely candidate as a conservative tracer in these studies. [76Se]CoSe was produced and used as the target material for the production of 76Br via the (p,n) reaction at a Cyclone 18/9 cyclotron. 76Br was separated from the target by thermochromatographic distillation using a semi-automated system, combining a quartz glass apparatus with a synthesis module. 76Br was successfully produced at the cyclotron with a physical yield of 72 MBq/µAh (EOB). The total radiochemical yield of 76Br from the irradiated [76Se]CoSe target (EOS) was 68.6%. A total of 40 MBq–100 MBq n.c.a. 76Br were routinely prepared for PET experiments in 3 mL 20 mM Cl− solution. The spatial resolution of a PET scan with 76Br in geological materials was determined to be about 5 mm. The established procedure enables the routine investigation of hydrodynamics by PET techniques in geological materials that strongly sorb commonly used PET tracers such as 18F.
23 March 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Radioactive contaminations in soil, which originate from nuclear power production, nuclear weapon testing, or uncontrolled release, are of great environmental concern. One of the major fission product contaminants is 90Sr, whose high mobility demands a method to track contamination pathways and remediation processes. Positron emission tomography (PET) is a valuable tool for the required studies. As a β−/γ-emitter, 90Sr is not suitable for PET, which requires β+-emitters. As an alternative, 83Sr, with a 12% intensity of β+-emission and a half-life of 32.4 h, is an appropriate PET substitute for 90Sr. We produced 83Sr with an enriched target of [85Rb]RbCl in a 85Rb(p,3n)83Sr reaction. The target material was bombarded with 36.22 MeV protons (ø 1.78 µA, 315 min), at a solid target station at the cyclotron U-120M (NPI CAS). The irradiated target (1.5 GBq) was dissolved in water, evaporated to dryness, redissolved in nitric acid, and transferred onto a Sr-selective cartridge (Sr-SpecTM, TRISKEM, France). Following target material wash out, 83Sr elution with water, solvent evaporation, and reformulation (in dilute nitric acid) yielded 1.2 GBq (82% radiochemical extraction efficiency, non-decay-corrected) of an 83Sr-solution. The easy and fast method is able to produce non-carrier-added 83Sr with high radionuclidic purity.