This article shows a study of the level of reliability of welded and bolted connections in cold formed steel members, for some limiting states, adopted by AISI and Brazilian codes. The aim of this study is the assessment of the reliability index β for a variation of the nominal live-to-dead load ratios as well as comparison of the value found considering different load combinations. The first order reliability method is used to calculate the reliability index β. In this study, reliability indices smaller than 3.5 were obtained, especially for bolted connections. Consideration of the model errors and FORM method, lead to significant reductions in reliability indices, which are found to be less than the recommended target reliability levels.
1 July 2018 in REM - International Engineering Journal
The design codes for structural design traditionally establish the adoption of partial safety factors to deal with uncertainties. These standards do not allow one to know the real probabilities of failure of a structure. What is needed, from a practical and scientific point of view, is a more consistent approach, based on reliability theory. This article addresses an initial attempt at determining the safety levels of structures based on advanced analysis and design with structural reliability theory. In this context, the authors consider the effects of the geometric nonlinearity and flexibility of connections in the reliability analysis, which aims at setting a certain displacement as the service limit state. For this purpose, a computer program was written called Structural Reliability Module. This program uses a First Order Reliability Method to analyse reliability. To carry out the structural analysis of steel structures, this study uses the program Computational System for Advanced Structural Analysis. Validating the Structural Reliability Module involved comparing the results from other authors with those generated by the program. Results for the structures under study indicate the efficiency of the implemented measures. Results suggest that, when a certain displacement is set as a service limit state, the reliability of the structures under analysis are only slightly influenced by geometric nonlinearity but considerably so by semi-rigid connections.
The objective of this paper is to provide a review of the calibration procedure of the resistance factor for a target reliability index. Resistance factors for cold-formed steel columns are calculated with a first order second moment reliability approach. A test database of 323 cold-formed steel columns concentrically loaded with plain and lipped C-section was assembled, and test-to-predicted statistics were obtained for the three design methods available in Brazilian cold-formed steel code: the Effective Width Method (EWM), the Effective Section Method (ESM) and the Direct Strength Method (DSM). For the normal load combination, dead-to-live load ratio of 1/3, and target reliability index or = 2.5, the calculated resistance factors, g, for the three methods are consistent with current value specified by Brazilian code. For all methods, with target reliability index or = 3.0, the calculated resistance factors, g, are higher than the current value used in Brazilian code.
1 June 2021 in REM - International Engineering Journal
This article presents a procedure for the reliability assessment of cold-formed steel beams based on the Direct Strength Method (DSM) and the Effective Section Method (ESM). Using a comprehensive database, a statistical analysis of the test results was performed to determine the statistical properties of the professional factor random variable. The statistical parameters related to material strength, geometric properties and load effects were obtained from established references for reliability analysis. Safety levels compatible with the North American and the Brazilian codes relating to structural design of cold-formed steel members have been established. The first-order reliability method (FORM) was used to calculate resistance factors φ for usual nominal live-dead ratios. The results of the reliability analysis showed that the DSM and ESM design methods have similar levels of reliability. The same resistance factor as the DSM can be used for the ESM, without compromising the minimum level of reliability established. The results obtained with the LRFD calibration data, presented a good approximation with the load factor φ = 0.90, except for the distortional mode. With the LSD calibration data, values well below the specified were required in order to achieve the required level of reliability. It was also found that the load factor γ = 1.25, in the format of the Brazilian standard, could reach the safety requirements established for all buckling modes.