Yang Zhao

Dr. Yang Zhao


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2021 in ACS Nano
Verified
Journal Article
Closed access
HZHongmei Zhong
Hongmei Zhong
YLYanan Li
Yanan Li
PZPeng Zhang
Peng Zhang
SGShouwei Gao
Shouwei Gao
BLBingying Liu
Bingying Liu
Zuankai WangZuankai Wang
Zuankai Wang

4 November 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
HZHongmei Zhong
Hongmei Zhong
PZPeng Zhang
Peng Zhang
YLYanan Li
Yanan Li
XYXiaochen Yang
Xiaochen Yang
YZYang Zhao
Yang Zhao
Zuankai WangZuankai Wang
Zuankai Wang

17 September 2018 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YPYu Pei
Yu Pei
HZHongmei Zhong
Hongmei Zhong
MWMengyu Wang
Mengyu Wang
PZPeng Zhang
Peng Zhang
YZYang Zhao
Yang Zhao
Vertically aligned carbon nanotube (CNT) arrays are promising candidates for advanced thermal interface materials (TIMs) since they possess high mechanical compliance and high intrinsic thermal conductivity. Some of the previous works indicate that the CNT arrays in direct dry contact with the target surface possess low contact thermal conductance, which is the dominant thermal resistance. Using a phase sensitive transient thermo-reflectance (PSTTR) technique, we measure the thermal conductance between CNT arrays and copper (Cu) surfaces under different pressures. The experiments demonstrated that the contact force is one of the crucial factors for optimizing the thermal performance of CNT array-based TIMs. The experimental results suggest that the Cu-CNT arrays’ contact thermal conductance has a strong dependence on the surface deformation and has an order of magnitude rise as the contact pressure increases from 0.05 to 0.15 MPa. However, further increase of the contact pressure beyond 0.15 MPa has little effect on the contact thermal resistance. This work could provide guidelines to determine the minimum requirement of packaging pressure on CNT TIMs.

21 April 2021 in Nano Letters
Verified
Journal Article
Closed access
TMTing Meng
Ting Meng
YSYiwen Sun
Yiwen Sun
CTChen Tong
Chen Tong
PZPeng Zhang
Peng Zhang
DXDongyan Xu
Dongyan Xu
YZYang Zhao
Yang Zhao

5 April 2012 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
PDF file
YZYang Zhao
Yang Zhao
LLLi‐Ning Lin
Li‐Ning Lin
YLYang Lu
Yang Lu
HGHuai‐Ling Gao
Huai‐Ling Gao
SCShao‐Feng Chen
Shao‐Feng Chen
SYShu‐Hong Yu
Shu‐Hong Yu

19 November 2024 in Advanced Science
Verified
Journal Article
Open access
ZLZhendong Luo
Zhendong Luo
PZPeng Zhang
Peng Zhang
HHHuwang Hou
Huwang Hou
YLYiming Li
Yiming Li
BLBinzhao Li
Binzhao Li
YZYang Zhao
Yang Zhao
Infrared (IR) radiation thermography is extensively utilized in diverse fields due to its non‐contact capability. Nevertheless, its effectiveness is often compromised by the significant emissivity variations among different objects, limiting its application to specific setups or focused object types. Colorimetric thermography is introduced as an alternative emissivity‐independent method of radiation thermometry. This technique involves measuring radiance across two or more spectral bands and calculating the object's temperature based on the signal ratio, thereby mitigating emissivity effects under certain conditions. However, this method has the trade‐off of necessitating bulky optical systems, complex filter imaging configurations, and sensor structures. To meet the requirements of IR thermography for compact structure, lightweight design, and customizability, a dual‐band metalens is developed for the IR colorimetric thermography. The central wavelengths targeted are 9.5 and 12.5 µm. The dual‐band IR imaging by the fabricated dual‐band metalens is demonstrated, and the colorimetric thermography of low‐emissivity objects is performed without presetting emissivity values. This approach significantly eliminates measurement errors associated with emissivity by an average of 50.16% across a temperature range of 60–180 °C. This innovation paves the way for dynamic and multi‐target thermography using compact IR systems in complex environments.