To determine if lymphatic channels and sentinel lymph nodes (SLNs) with and without metastases can be detected with lymphatic ultrasonography (US) after peritumoral injection of a US contrast agent and to determine if lymphatic US can be used to assess SLNs for the presence of metastatic infiltration. Six swine with 17 melanomas were evaluated. Conventional gray-scale, color flow, and gray-scale phase-inversion harmonic US examinations were performed. A US contrast agent was administered in four sites around each melanoma (1-mL total dose). Lymphoscintigraphy was followed by injection of a blue dye and then dissection. SLNs identified at lymphatic US were characterized by two readers in consensus as normal or as having metastases; results were compared with histologic findings. Statistical analyses included the sign test and the kappa statistic. Lymphatic US depicted 28 SLNs, while lymphoscintigraphy depicted 27 "hot spots" suspected of representing SLNs (including two false-positive findings). Dissection after blue dye injection helped identify 31 SLNs. There were no false-positive US findings for SLN detection. Five of six nodes not seen with lymphoscintigraphy were detected with lymphatic US. The accuracy of SLN detection was 90% (28 of 31) for lymphatic US and 81% (25 of 31) for lymphoscintigraphy (P =.29). Lymphatic US correctly depicted metastases in 19 of 20 SLNs, and five of the eight normal SLNs were correctly characterized, with an accuracy of 86% (kappa = 0.62). Detection of SLNs with lymphatic US compared favorably with that at lymphoscintigraphy. Lymphatic US can depict metastases within the SLN, which was not possible with lymphoscintigraphy.
To evaluate the flow imaging capabilities of a new prototype ultrasound (US) image processing technique (superb micro-vascular imaging [SMI]; Toshiba Medical Systems, Tokyo, Japan) for depiction of microvascular flow in normal thyroid tissue and thyroid nodules compared with standard color and power Doppler US imaging. Ten healthy volunteers and 22 patients, with a total of 25 thyroid nodules, scheduled for US-guided fine needle aspiration were enrolled in this prospective study. Subjects underwent US examination consisting of grayscale, color and power Doppler imaging (CDI and PDI) followed by color and monochrome SMI and pulsed Doppler. SMI is a novel, microvascular flow imaging mode implemented on the Aplio 500 US system (Toshiba). SMI uses advanced clutter suppression to extract flow signals from large to small vessels and depicts this information at high frame rates as a color overlay image or as a monochrome map of flow. Two radiologists independently scored still images and digital clips for overall flow detection, vessel branching details and noise on a visual-analog scale of 1 (worst) to 10 (best). For the volunteers SMI visualized microvasculature with significantly lower velocity than CDI and PDI (P < 0.012). In all thyroid nodules, SMI demonstrated microvascular flow with significantly higher image scores and provided better depiction of the vessel branching details compared with CDI and PDI (P < 0.0001). Clutter noise was significantly higher in monochrome SMI mode than in the other modes, including color SMI (P < 0.001). The novel SMI mode consistently improved the depiction of thyroid microvascular flow compared with standard CDI and PDI.
In this study, we correlated subharmonic aided pressure estimation data with the hepatic venous pressure gradient and found good overall agreement, indicating that this noninvasive technique may be... PurposeTo compare subharmonic aided pressure estimation (SHAPE) with pressure catheter–based measurements in human patients with chronic liver disease undergoing transjugular liver biopsy.Materials...
Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled confocally at a 60° angle to each other. Changes in the first, second and subharmonic amplitudes of five different ultrasound contrast agents were measured in vitro at static hydrostatic pressures from 0–186 mmHg, acoustic pressures from 0.35–0.60 MPa peak-to-peak and frequencies of 2.5–6.6 MHz. The most sensitive agent and optimal parameters for SHAPE were determined using linear regression analysis and implemented on a Logiq 9 scanner (GE Healthcare, Milwaukee, WI). This implementation of SHAPE was then tested under dynamic-flow conditions and compared to pressure-catheter measurements. Over the pressure range studied, the first and second harmonic amplitudes reduced approximately 2 dB for all contrast agents. Over the same pressure range, the subharmonic amplitudes decreased by 9–14 dB and excellent linear regressions were achieved with the hydrostatic pressure variations ( r2 = 0.98, p < 0.001). Optimal sensitivity was achieved at a transmit frequency of 2.5 MHz and acoustic pressure of 0.35 MPa using Sonazoid (GE Healthcare, Oslo, Norway). A Logiq 9 scanner was modified to implement SHAPE on a convex transducer with a frequency range from 1.5–4.5 MHz and acoustic pressures from 0–3.34 MPa. Results matched the pressure catheter ( r2 = 0.87). In conclusion, subharmonic contrast signals are a good indicator of hydrostatic pressure. Out of the five ultrasound contrast agents tested, Sonazoid was the most sensitive for subharmonic pressure estimation. Real-time SHAPE has been implemented on a commercial scanner and offers the possibility of allowing pressures in the heart and elsewhere to be obtained noninvasively.