Flemming Forsberg

Dr. Flemming Forsberg

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2004 in Radiology
Verified
Journal Article
Closed access
BGBarry B. Goldberg
Barry B. Goldberg
DMDaniel A. Merton
Daniel A. Merton
JLJi-Bin Liu
Ji-Bin Liu
Mathew ThakurMathew Thakur
Mathew Thakur
GMGeorge F. Murphy
George F. Murphy
FFFlemming Forsberg
Flemming Forsberg
To determine if lymphatic channels and sentinel lymph nodes (SLNs) with and without metastases can be detected with lymphatic ultrasonography (US) after peritumoral injection of a US contrast agent and to determine if lymphatic US can be used to assess SLNs for the presence of metastatic infiltration. Six swine with 17 melanomas were evaluated. Conventional gray-scale, color flow, and gray-scale phase-inversion harmonic US examinations were performed. A US contrast agent was administered in four sites around each melanoma (1-mL total dose). Lymphoscintigraphy was followed by injection of a blue dye and then dissection. SLNs identified at lymphatic US were characterized by two readers in consensus as normal or as having metastases; results were compared with histologic findings. Statistical analyses included the sign test and the kappa statistic. Lymphatic US depicted 28 SLNs, while lymphoscintigraphy depicted 27 "hot spots" suspected of representing SLNs (including two false-positive findings). Dissection after blue dye injection helped identify 31 SLNs. There were no false-positive US findings for SLN detection. Five of six nodes not seen with lymphoscintigraphy were detected with lymphatic US. The accuracy of SLN detection was 90% (28 of 31) for lymphatic US and 81% (25 of 31) for lymphoscintigraphy (P =.29). Lymphatic US correctly depicted metastases in 19 of 20 SLNs, and five of the eight normal SLNs were correctly characterized, with an accuracy of 86% (kappa = 0.62). Detection of SLNs with lymphatic US compared favorably with that at lymphoscintigraphy. Lymphatic US can depict metastases within the SLN, which was not possible with lymphoscintigraphy.

1 March 2016 in Ultrasound Quarterly
Verified
Journal Article
Closed access
PMPriscilla Machado
Priscilla Machado
SSSharon Do Segal
Sharon Do Segal
ALAndrej Lyshchik
Andrej Lyshchik
FFFlemming Forsberg
Flemming Forsberg
To evaluate the flow imaging capabilities of a new prototype ultrasound (US) image processing technique (superb micro-vascular imaging [SMI]; Toshiba Medical Systems, Tokyo, Japan) for depiction of microvascular flow in normal thyroid tissue and thyroid nodules compared with standard color and power Doppler US imaging. Ten healthy volunteers and 22 patients, with a total of 25 thyroid nodules, scheduled for US-guided fine needle aspiration were enrolled in this prospective study. Subjects underwent US examination consisting of grayscale, color and power Doppler imaging (CDI and PDI) followed by color and monochrome SMI and pulsed Doppler. SMI is a novel, microvascular flow imaging mode implemented on the Aplio 500 US system (Toshiba). SMI uses advanced clutter suppression to extract flow signals from large to small vessels and depicts this information at high frame rates as a color overlay image or as a monochrome map of flow. Two radiologists independently scored still images and digital clips for overall flow detection, vessel branching details and noise on a visual-analog scale of 1 (worst) to 10 (best). For the volunteers SMI visualized microvasculature with significantly lower velocity than CDI and PDI (P < 0.012). In all thyroid nodules, SMI demonstrated microvascular flow with significantly higher image scores and provided better depiction of the vessel branching details compared with CDI and PDI (P < 0.0001). Clutter noise was significantly higher in monochrome SMI mode than in the other modes, including color SMI (P < 0.001). The novel SMI mode consistently improved the depiction of thyroid microvascular flow compared with standard CDI and PDI.

1 August 2013 in Radiology
Verified
Journal Article
Closed access
JEJohn R. Eisenbrey
John R. Eisenbrey
JDJaydev K. Dave
Jaydev K. Dave
VHValgerdur G. Halldorsdottir
Valgerdur G. Halldorsdottir
DMDaniel A. Merton
Daniel A. Merton
CMCynthia Miller
Cynthia Miller
FFFlemming Forsberg
Flemming Forsberg
In this study, we correlated subharmonic aided pressure estimation data with the hepatic venous pressure gradient and found good overall agreement, indicating that this noninvasive technique may be... PurposeTo compare subharmonic aided pressure estimation (SHAPE) with pressure catheter–based measurements in human patients with chronic liver disease undergoing transjugular liver biopsy.Materials...

23 February 2022 in Materials Advances
Verified
Journal Article
Open access
PDF file
LDLauren J. Delaney
Lauren J. Delaney
SISelin Isguven
Selin Isguven
John EisenbreyJohn Eisenbrey
John Eisenbrey
NHNoreen J. Hickok
Noreen J. Hickok
FFFlemming Forsberg
Flemming Forsberg
A review article regarding ultrasound-triggered drug delivery, highlighting exciting clinical trials and new applications for this modality.

2 April 2010 in Journal of Controlled Release
Verified
Journal Article
Closed access
JEJ.R. Eisenbrey
J.R. Eisenbrey
OBO. Mualem Burstein
O. Mualem Burstein
RKR. Kambhampati
R. Kambhampati
FFFlemming Forsberg
Flemming Forsberg
JLJ.-B. Liu
J.-B. Liu
MWM.A. Wheatley
M.A. Wheatley

1 July 2011 in Ultrasonic Imaging
Verified
Journal Article
Open access
PDF file
VHValgerdur G. Halldorsdottir
Valgerdur G. Halldorsdottir
JDJaydev K. Dave
Jaydev K. Dave
LLLauren M. Leodore
Lauren M. Leodore
JEJohn R. Eisenbrey
John R. Eisenbrey
SPSuhyun Park
Suhyun Park
FFFlemming Forsberg
Flemming Forsberg
Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled confocally at a 60° angle to each other. Changes in the first, second and subharmonic amplitudes of five different ultrasound contrast agents were measured in vitro at static hydrostatic pressures from 0–186 mmHg, acoustic pressures from 0.35–0.60 MPa peak-to-peak and frequencies of 2.5–6.6 MHz. The most sensitive agent and optimal parameters for SHAPE were determined using linear regression analysis and implemented on a Logiq 9 scanner (GE Healthcare, Milwaukee, WI). This implementation of SHAPE was then tested under dynamic-flow conditions and compared to pressure-catheter measurements. Over the pressure range studied, the first and second harmonic amplitudes reduced approximately 2 dB for all contrast agents. Over the same pressure range, the subharmonic amplitudes decreased by 9–14 dB and excellent linear regressions were achieved with the hydrostatic pressure variations ( r2 = 0.98, p < 0.001). Optimal sensitivity was achieved at a transmit frequency of 2.5 MHz and acoustic pressure of 0.35 MPa using Sonazoid (GE Healthcare, Oslo, Norway). A Logiq 9 scanner was modified to implement SHAPE on a convex transducer with a frequency range from 1.5–4.5 MHz and acoustic pressures from 0–3.34 MPa. Results matched the pressure catheter ( r2 = 0.87). In conclusion, subharmonic contrast signals are a good indicator of hydrostatic pressure. Out of the five ultrasound contrast agents tested, Sonazoid was the most sensitive for subharmonic pressure estimation. Real-time SHAPE has been implemented on a commercial scanner and offers the possibility of allowing pressures in the heart and elsewhere to be obtained noninvasively.