Kwang Soup Song

Dr. Kwang Soup Song

Kumoh National Institute of Technology

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
DKDae Hoon Kim
Dae Hoon Kim
HOHong Gi Oh
Hong Gi Oh
WPWoo Hwan Park
Woo Hwan Park
DJDong Cheol Jeon
Dong Cheol Jeon
KLKi Moo Lim
Ki Moo Lim
KSKwang Soup Song
Kwang Soup Song
The detection of alpha-fetoprotein (AFP) in plasma is important in the diagnosis of hepatocellular carcinoma (HCC) in humans. We developed a biosensor to detect AFP in HCC patient plasma and in a phosphate buffer saline (PBS) solution using a graphene field-effect transistor (G-FET). The G-FET was functionalized with 1-pyrenebutyric acid N-hydroxysuccinimide ester (PBASE) for immobilization of an anti-AFP antibody. AFP was detected by assessing the shift in the voltage of the Dirac point (ΔVDirac) after binding of AFP to the anti-AFP-immobilized G-FET channel surface. This anti-AFP-immobilized G-FET biosensor was able to detect AFP at a concentration of 0.1 ng mL−1 in PBS, and the detection sensitivity was 16.91 mV. In HCC patient plasma, the biosensor was able to detect AFP at a concentration of 12.9 ng mL−1, with a detection sensitivity of 5.68 mV. The sensitivity (ΔVDirac) depended on the concentration of AFP in either PBS or HCC patient plasma. These data suggest that G-FET biosensors could have practical applications in diagnostics.

22 May 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
JPJun I. K. Park
Jun I. K. Park
AHAulia Khamas Heikhmakhtiar
Aulia Khamas Heikhmakhtiar
CKChang Hyun Kim
Chang Hyun Kim
YKYoo Seok Kim
Yoo Seok Kim
SCSeong Wook Choi
Seong Wook Choi
KLKi Moo Lim
Ki Moo Lim
Although it is important to analyze the hemodynamic factors related to the right ventricle (RV) after left ventricular assist device (LVAD) implantation, previous studies have focused only on the alteration of the ventricular shape and lack quantitative analysis of the various hemodynamic parameters. Therefore, we quantitatively analyzed various hemodynamic parameters related to the RV under normal, heart failure (HF), and HF incorporated with continuous flow LVAD therapy by using a computational model. In this study, we combined a three-dimensional finite element electromechanical model of ventricles, which is based on human ventricular morphology captured by magnetic resonance imaging (MRI) with a lumped model of the circulatory system and continuous flow LVAD function in order to construct an integrated model of an LVAD implanted-cardiovascular system. To induce systolic dysfunction, the magnitude of the calcium transient function under HF condition was reduced to 70% of the normal value, and the time constant was reduced by 30% of the normal value. Under the HF condition, the left ventricular end systolic pressure decreased, the left ventricular end diastolic pressure increased, and the pressure in the right atrium (RA), RV, and pulmonary artery (PA) increased compared with the normal condition. The LVAD therapy decreased the end-systolic pressure of the LV by 41%, RA by 29%, RV by 53%, and PA by 71%, but increased the right ventricular ejection fraction by 52% and cardiac output by 40%, while the stroke work was reduced by 67% compared with the HF condition without LVAD. The end-systolic ventricular tension and strain decreased with the LVAD treatment. LVAD enhances CO and mechanical unloading of the LV as well as those of the RV and prevents pulmonary hypertension which can be induced by HF.

3 June 2025 in npj Clean Water
Verified
Journal Article
Open access
PDF file
VMVelu Manikandan
Velu Manikandan
DEDuraisamy Elango
Duraisamy Elango
VSVelu Subash
Velu Subash
PKPonnuchamy Kumar
Ponnuchamy Kumar
JPJeyakumar Saranya Packialakshmi
Jeyakumar Saranya Packialakshmi
KSKwang Soup Song
Kwang Soup Song
This study investigates the synthesis of ZrOx-loaded NiFe2O4 photocatalysts (1, 2, and 3 wt%) through co-precipitation and wet impregnation methods for environmental and health applications. The structural analysis revealed a cubic crystal structure, with ZrOx doping enhancing charge separation and mobility by converting the morphology from fibrous to needle-like. Under visible light (VL) and H2O2 activation, the ZrOx(3 wt%)/NiFe2O4 composite achieved high degradation efficiencies (98.5% for Bisphenol A and 98.2% for 4-Nitrophenol) in 120 min via the Photo-Fenton mechanism. Kinetic analysis showed pseudo-first-order behavior with rate constants of 0.945 min−1 for BPA and 0.904 min−1 for 4-NP. The catalyst demonstrated stability with 91.5% efficiency retention after multiple cycles. DFT calculations indicated favorable HOMO-LUMO alignments and electrostatic potentials. Additionally, ZrOx(3 wt%)/NiFe2O4 exhibited selective cytotoxicity against breast cancer cell lines, while maintaining high viability in HEK-293 cells. The results suggest that ZrOx(3 wt%)/NiFe2O4 composites are promising for environmental and biomedical applications.

28 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DKDae Hoon Kim
Dae Hoon Kim
WPWoo Hwan Park
Woo Hwan Park
HOHong Gi Oh
Hong Gi Oh
DJDong Cheol Jeon
Dong Cheol Jeon
JLJoon Mook Lim
Joon Mook Lim
KSKwang Soup Song
Kwang Soup Song
A reference electrode is necessary for the working of ion-sensitive field-effect transistor (ISFET)-type sensors in electrolyte solutions. The Ag/AgCl electrode is normally used as a reference electrode. However, the Ag/AgCl reference electrode limits the advantages of the ISFET sensor. In this work, we fabricated a two-channel graphene solution gate field-effect transistor (G-SGFET) to detect pH without an Ag/AgCl reference electrode in the electrolyte solution. One channel is the sensing channel for detecting the pH and the other channel is the reference channel that serves as the reference electrode. The sensing channel was oxygenated, and the reference channel was fluorinated partially. Both the channels were directly exposed to the electrolyte solution without sensing membranes or passivation layers. The transfer characteristics of the two-channel G-SGFET showed ambipolar field-effect transistor (FET) behavior (p-channel and n-channel), which is a typical characteristic curve for the graphene ISFET, and the value of VDirac was shifted by 18.2 mV/pH in the positive direction over the range of pH values from 4 to 10. The leakage current of the reference channel was 16.48 nA. We detected the real-time pH value for the two-channel G-SGFET, which operated stably for 60 min in the buffer solution.

4 April 2024 in Polymers for Advanced Technologies
Verified
Journal Article
Closed access
VMVelu Manikandan
Velu Manikandan
DEDuraisamy Elango
Duraisamy Elango
MAMysoon M. Al‐Ansari
Mysoon M. Al‐Ansari
VSVelu Subash
Velu Subash
RMR. Mythili
R. Mythili
KSKwang Soup Song
Kwang Soup Song

19 March 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
HOHong Gi Oh
Hong Gi Oh
DJDong Cheol Jeon
Dong Cheol Jeon
MGMahmudah Salwa Gianti
Mahmudah Salwa Gianti
HCHae Shin Cho
Hae Shin Cho
DJDa Ae Jo
Da Ae Jo
KSKwang Soup Song
Kwang Soup Song
The monitoring of Na+ ions distributed in the body has been indirectly calculated by the detection of Na+ ions in urine. We fabricated a two–dimensional (2D) Na+ ion sensor using a graphene ion–sensitive field–effect transistor (G–ISFET) and used fluorinated graphene as a reference electrode (FG–RE). We integrated G–ISFET and FG on a printed circuit board (PCB) designed in the form of a secure digital (SD) card to fabricate a disposable Na+ ion sensor. The sensitivity of the PCB tip to Na+ ions was determined to be −55.4 mV/dec. The sensor exhibited good linearity despite the presence of interfering ions in the buffer solution. We expanded the evaluation of the PCB tip to real human patient urine samples. The PCB tip exhibited a sensitivity of −0.36 mV/mM and linearly detected Na+ ions in human patient urine without any dilution process. We expect that G–ISFET with FG–RE can be used to realize a disposable Na+ ion sensor by serving as an alternative to Ag/AgCl reference electrodes.