2 April 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
SGStanislavs Gendelis
Stanislavs Gendelis
PSPetro Shamilov
Petro Shamilov
AJAndris Jakovičs
Andris Jakovičs
PBPavlo Biriukovych
Pavlo Biriukovych
SKSergii Khmelenko
Sergii Khmelenko
Thermal bridges at window installations significantly influence the energy performance and indoor comfort of buildings, particularly in nearly zero energy buildings (nZEB). This study investigates the impact of window mounting-position on thermal-bridge intensity at window-to-wall junctions using finite element method (FEM) simulations of representative junction configurations. Mounting depth, frame alignment relative to the insulation layer, and junction detailing were systematically varied to quantify their effect on linear thermal transmittance (ψ-values) and internal-surface temperatures. The results show that relatively small changes in mounting position can markedly reduce thermal-bridge effects; the most effective strategy combines installing the window within the insulation layer at an optimal depth of 7–12 cm. Across the studied configurations, ψ decreased from traditional installation values of 0.27 W/(m·K) to 0.02 W/(m·K) for installation in the insulation layer, and with frame overlap and frame extenders, the ψ-value can be further reduced, reaching 0.005 W/(m·K) in the best case. Applying external insulation increases the minimum internal-surface temperature by at least 2 °C compared with cases without frame covering. In the case study of a historical building retrofitted to Passive House (PH) standard, installing windows in the insulation layer reduced annual heating demand from 32 kWh/m2 to 24 kWh/m2. The additional investment is economically justified, with a simple payback period of about 25 years, decreasing to around 20 years assuming a 3% annual increase in energy prices. These findings demonstrate that optimised window positioning is an effective and economically viable measure to improve the energy performance, durability, and sustainability of high-performance buildings.

3 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
SGStanislavs Gendelis
Stanislavs Gendelis
PSPetro Shamilov
Petro Shamilov
AJAndris Jakovics
Andris Jakovics
PBPavlo Biriukovych
Pavlo Biriukovych
SKSergii Khmelenko
Sergii Khmelenko
Thermal bridges at window installations significantly influence the energy performance and indoor comfort of buildings, particularly in nearly Zero Energy Buildings (nZEB). Even in well-insulated and airtight building envelopes, improper window integration can cause substantial localized heat losses and increase the risk of surface condensation and mould growth. This study investigates the impact of window mounting position on thermal bridge intensity at window-to-wall junctions. Finite Element Method (FEM) simulations were used to analyse heat transfer in representative junction configurations. Mounting depth, frame alignment relative to the insulation layer, and junction detailing were systematically varied to determine their effect on linear thermal transmittance (Ψ-values). The simulations show that relatively small changes in mounting position can significantly reduce thermal bridge effects. The lowest heat losses and highest internal surface temperatures — thus lowest condensation risk — were achieved when the window frame was positioned in the insulation layer and partially embedded within it. Application of these optimized installation details in a case study of a historical building retrofitted to Passive House (PH) standard resulted in a measurable reduction in annual heating demand and a favourable payback period. The findings demonstrate that careful window positioning during installation is an effective and economically viable measure to improve the energy performance and durability of high-performance buildings.