Jeong Jun Park

Prof. Dr. Jeong Jun Park


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
NCNoo Ree Cho
Noo Ree Cho
JCJeong Ho Cha
Jeong Ho Cha
JPJeong Jun Park
Jeong Jun Park
YKYun Hak Kim
Yun Hak Kim
DKDai Sik Ko
Dai Sik Ko
Background: Ultrasound-guided regional anesthesia has gained popularity over the last decade. This study aimed to assess whether YouTube videos sufficiently serve as an adjunctive tool for learning how to perform an ultrasound-guided brachial plexus block (BPB). Methods: All YouTube videos were classified, based on their sources, as either academic, manufacturer, educational, or individual videos. The metrics, accuracy, utility, reliability (using the Journal of American Medical Association Score benchmark criteria (JAMAS)), and educational quality (using the Global Quality Score (GQS) and Brachial Plexus Block Specific Quality Score (BSQS)) were validated. Results: Here, 175 videos were included. Academic (1.19 ± 0.62, mean ± standard deviation), manufacturer (1.17 ± 0.71), and educational videos (1.15 ± 0.76) had better JAMAS accuracy and reliability than individual videos (0.26 ± 0.67) (p < 0.001). Manufacturer (11.22 ± 1.63) and educational videos (10.33 ± 3.34) had a higher BSQS than individual videos (7.32 ± 4.20) (p < 0.001). All sources weakly addressed the equipment preparation and post-procedure questions after BSQS analysis. Conclusions: The reliability and quality of ultrasound-guided BPB videos differ depending on their source. As YouTube is a useful educational platform for learners and teachers, global societies of regional anesthesiologists should set a standard for videos.

12 June 2023 in Microvascular Research
Verified
Journal Article
Closed access
DKDai Sik Ko
Dai Sik Ko
SBSeung Eun Baek
Seung Eun Baek
MHMihyang Ha
Mihyang Ha
JPJeong Jun Park
Jeong Jun Park
CLChangjin Lee
Changjin Lee
YKYun Hak Kim
Yun Hak Kim

13 March 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
HHHyub Huh
Hyub Huh
JPJeong Jun Park
Jeong Jun Park
Point-of-care ultrasound (POCUS) is portable and radiation-free, but its clinical reliability is constrained by operator-dependent image acquisition and the limited scalability of expert quality assurance (QA) review. As handheld devices proliferate faster than mentorship capacity, trainees increasingly rely on heterogeneous free open access medical education (FOAMed) resources that rarely provide real-time psychomotor feedback. We conducted a structured narrative review (MEDLINE, Embase, Scopus, and Web of Science; last searched on 23 February 2026), with searches performed by H.H. and independently checked by J.J.P. (both POCUS-trained clinicians). After screening, 31 studies were included. We synthesized evidence on artificial intelligence (AI) systems that support bedside image acquisition and automate QA. The primary synthesis centered on key prospective or comparative clinical evaluations of AI-guided acquisition across echocardiography, focused assessment with sonography in trauma, abdominal aortic aneurysm screening, and lung ultrasound, complemented by peer-reviewed studies of FOAMed appraisal tools and online resource quality. These evaluations suggest that real-time probe guidance, view recognition, anatomy labeling, and automated capture may enable novices, after brief training, to acquire diagnostically adequate images for narrowly defined tasks. Early reports of automated QA scoring and program-level triage for expert review suggest potential to reduce expert workload and shorten feedback cycles, but external validation, generalizability across devices and patient habitus, and patient-centered outcomes remain limited. Acquisition-focused AI may therefore serve as an upstream “digital mentor” to improve novice image acquisition. We propose a practical pathway that integrates curated FOAMed resources and simulation with AI-guided bedside acquisition and continuous QA governance for safe deployment.

16 July 2026 in Life
Verified
Journal Article
Open access
PDF file
JPJeong Jun Park
Jeong Jun Park
GYGwi Eun Yeo
Gwi Eun Yeo
YKYoura Kim
Youra Kim
JKJoonhyung Kim
Joonhyung Kim
Childhood myopia is increasingly discussed in relation to digital device use, yet total screen duration is biologically nonspecific (not tied to a single biological cause) and may combine outdoor-light deficit, near work intensity, educational routines, and sleep/circadian timing. This critical narrative review used structured database searches to support transparent source identification, not systematic completeness, quantitative pooling, or formal risk-of-bias grading. We narratively appraised evidence by design, exposure specificity, outcome specificity, temporality, and clinical directness, then derived a measurement framework. Outdoor light exposure has the strongest support for preventing incident myopia. Near work and the visual demands of schooling are important, but they are measured in inconsistent ways. Sleep and circadian timing remain biologically plausible, albeit lower-certainty modifiers. Digital device metrics are best interpreted as contextual measurement markers that can recover timing, bout structure, task context, substitution, and adherence, rather than as standalone causal surrogates (stand-ins for a true cause). The proposed framework prioritizes direct measurement of outdoor light, near work intensity, sleep/circadian timing, and axial-growth outcomes, using device-related behavior only when it clarifies daily exposure patterns. This is a narrative review of previously described behavioral factors; it does not identify new risk factors or propose a novel causal model. For measurement, it groups these behaviors by how they occur together across a single day and separates substitution, mediation, interaction, and temporal clustering as distinct estimands (the specific quantities to be estimated). Its purpose is to improve exposure measurement and hypothesis testing, not to establish digital device use, sleep timing, or clustered routines as independent causal risk factors.

3 March 2026 in Nutrients
Verified
Journal Article
Open access
PDF file
DLDong Hee Lee
Dong Hee Lee
JPJeong Jun Park
Jeong Jun Park
Background/Objectives: Lower urinary tract symptoms (LUTSs), particularly nocturia and urgency, often intensify during the menopause transition and may worsen with caffeine intake and cold exposure. This review aims to synthesize evidence relevant to a hypothesized caffeine–cold interaction in transitional menopause, focusing on water homeostasis and the estrogen–transient receptor potential melastatin 8 (TRPM8) cold-sensory axis, and to propose potentially actionable, nutrition-centered intervention candidates for future testing. Methods: Structured narrative review of PubMed, Embase, Web of Science, and citation tracking (inception–January 2026). Evidence was mapped into a mechanistic framework distinguishing established from hypothesis-generating links; no formal systematic-review study selection or meta-analysis was performed. Results: Caffeine can increase urine output via renal mechanisms (adenosine receptor antagonism and natriuresis) and may lower bladder sensory thresholds. Because half-life is long and variable, afternoon intake can extend into sleep, potentially increasing awakenings and nocturnal voids. Human studies link colder indoor environments to nocturia/overactive bladder, and passive pre-bedtime heating is associated with fewer nocturnal voids. We propose that repeated nighttime cold may amplify caffeine-related diuresis and may shift urine production toward the night, while estradiol decline may heighten TRPM8-mediated cold sensory gain, potentially contributing to urgency/frequency flares. A testable 2 × 2 cold × caffeine framework can operationalize dose, timing, and metabolism, pairing voiding diaries and bedroom temperature sensing with copeptin profiling. Conclusions: Transitional menopause may represent a susceptibility window in which endocrine instability and estradiol decline could plausibly increase sensitivity to indoor cold exposure and caffeine intake, potentially contributing to nocturia and urgency. The hypothesis label ‘dual hormone suppression’ (attenuated nocturnal AVP signal plus estradiol decline) may provide a mechanistic substrate for cold-exacerbated nocturnal polyuria, while an estrogen–TRPM8 axis may amplify cold-evoked urgency. Potentially actionable candidates include chronobiological caffeine timing/management and low-burden thermal strategies; nevertheless, menopause-stage-specific epidemiologic and clinical evidence for a caffeine × cold interaction remains limited and several mechanistic links are extrapolated, so prospective diary- and biomarker-enabled studies and controlled trials are needed to validate mechanisms and refine cold-sensitive endotypes.