Bernhard Maria Speth

Dr. Bernhard Maria Speth

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2010 in Annals of Oncology
Verified
Journal Article
Open access
PDF file
AKAndreas H. Krieg
Andreas H. Krieg
FHF. Hefti
F. Hefti
BSBernhard Maria Speth
Bernhard Maria Speth
GJG. Jundt
G. Jundt
LGL. Guillou
L. Guillou
MCM. D. Cserhati
M. D. Cserhati
Background: Synovial sarcoma (SS) is a malignant soft tissue sarcoma with a poor prognosis because of late local recurrence and distant metastases. To our knowledge, no studies have minimum follow-up of 10 years that evaluate long-term outcomes for survivors. Patients and methods: Data on 62 patients who had been treated for SS from 1968 to 1999 were studied retrospectively in a multicenter study. Mean follow-up of living patients was 17.2 years and of dead patients 7.7 years. Results: Mean age at diagnosis was 35.4 years (range 6–82 years). Overall survival was 38.7%. The 5-year survival was 74.2%; 10-year survival was 61.2%; and 15-year survival was 46.5%. Fifteen patients (24%) died of disease after 10 years of follow-up. Local recurrence occurred after a mean of 3.6 years (range 0.5–14.9 years) and metastases at a mean of 5.7 years (range 0.5–16.3 years). Only four patients were treated technically correctly with a planned biopsy followed by a wide resection or amputation. Factors associated with significantly worse prognosis included larger tumor size, metastases at the time of diagnosis, high-grade histology, trunk-related disease, and lack of wide resection as primary surgical treatment. Conclusions: In SS, metastases develop late with high mortality. Patients with SS should be followed for >10 years.

11 May 2011 in Acta Orthopaedica
Verified
Journal Article
Open access
AKAndreas H. Krieg
Andreas H. Krieg
ULUlrich Lenze
Ulrich Lenze
BSBernhard Maria Speth
Bernhard Maria Speth
CHCarol C Hasler
Carol C Hasler
In the last decade, intramedullary limb lengthening has become a viable alternative to traditional external systems. We retrospectively analyzed the use of an intramedullary motorized nail (Fitbone) in a consecutive series of 32 patients. During the period September 2006 to December 2008, 32 consecutive patients with a median age of 17 (IQR: 15-19) years were treated with a fully implantable, motorized intramedullary lengthening device (Fitbone). The median leg length discrepancy was 35 (IQR: 30-44) mm at the femur (n = 21) and 28 (IQR: 25-30) mm at the tibia (n = 11). Leg lengthening was successful in 30 of 32 cases, with no residual relevant discrepancy (± 5 mm). No intraoperative complications were observed. The consolidation index was significantly different (p = 0.04) between femoral lengthening (mean 35 days/cm) and tibial lengthening (mean 48 days/cm) but did not depend on age older/younger than 16 or previous operations at the affected site. 3 problems, 3 obstacles, and 4 complications (3 minor, 1 major) were encountered in 8 patients, 5 of which were implant-associated. This technique even allows correction in patients with multiplanar deformities. Compared to external devices, intramedullary systems provide comfort and reduce complication rates, give improved cosmetic results, and lead to fast rehabilitation since percutaneous, transmuscular fixation is prevented. This results in reasonable overall treatment costs despite the relatively high costs of implants.

1 January 2008 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
PDF file
AKAndreas H. Krieg
Andreas H. Krieg
BSBernhard Maria Speth
Bernhard Maria Speth
BFBruce K. Foster
Bruce K. Foster
Leg lengthening by external fixation is associated with various difficulties. We evaluated eight adolescent patients who underwent leg lengthening with a motorized intramedullary lengthening device. We asked whether this method could reduce the time of hospitalization and rehabilitation and whether the incidence of complications commonly associated with external fixators could be reduced. We compared our preliminary results with those from other reports, with a focus on leg length achieved, time of rehabilitation, and rate of complications. The average leg-length discrepancy was 3.8 cm (range, 3–5 cm). The average lengthening distance was 3.8 cm (range, 2.9–4.7 cm). In six patients, leg lengthening was combined with successful correction of the mechanical axis alignment. The consolidation index averaged 26 days/cm (range, 19–41 days/cm). The average hospital stay was 9.6 days. No bone or soft tissue infections were observed. In comparison to other studies (1.0–2.8 complications/patient), our results suggest that the difficulties commonly associated with external fixators can be reduced with this method. It also allows good angular correction in patients with mechanical axis deviation. These features combined with a short time of hospitalization and rehabilitation make it a promising procedure for limb lengthening. Level of Evidence: Level IV Therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

1 March 2009 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Open access
PDF file
AKAndreas H. Krieg
Andreas H. Krieg
MMM. Mani
M. Mani
BSBernhard Maria Speth
Bernhard Maria Speth
PSP. D. Stalley
P. D. Stalley
NLN. Lubega
N. Lubega
WHW. J. Harrison
W. J. Harrison
We review the treatment of pelvic Ewing’s sarcoma by the implantation of extracorporeally-irradiated (ECI) autografts and compare the outcome with that of other reported methods. We treated 13 patients with ECI autografts between 1994 and 2004. There were seven males and six females with a median age of 15.7 years (interquartile range (IQR) 12.2 to 21.7). At a median follow-up of five years (IQR 1.8 to 7.4), the disease-free survival was 69% overall, and 75% if one patient with local recurrence after initial treatment elsewhere was excluded. Four patients died from distant metastases at a mean of 17 months (13 to 23). There were three complications which required operative intervention; one was a deep infection which required removal of the graft. The functional results gave a mean Musculoskeletal Tumor Society score of 85% (60% to 97%), a mean Toronto extremity salvage score of 86% (69% to 100%) and a mean Harris hip score of 92 (67 to 100). We conclude that ECI grafting is a suitable form of treatment for localised and resectable pelvic Ewing’s sarcoma.

1 August 2009 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Open access
AKAndreas H. Krieg
Andreas H. Krieg
BSBernhard Maria Speth
Bernhard Maria Speth
POP. E. Ochsner
P. E. Ochsner
KHK. T. Hwang
K. T. Hwang
YKY. S. Kim
Y. S. Kim
JRJ. A. Ryu
J. A. Ryu
Polyethylene wear of acetabular components is a key factor in the development of periprosthetic osteolysis and wear at the articular surface has been well documented and quantified, but fewer data are available about changes which occur at the backside of the liner. At revision surgery for loosening of the femoral component we retrieved 35 conventional modular acetabular liners of the same design. Linear and volumetric articular wear, backside volumetric change and the volume of the screw-head indentations were quantified. These volumes, clinical data and the results from radiological Ein Bild Röntgen Analyse migration analysis were used to identify potential factors influencing the volumetric articular wear and backside volumetric change. The rate of backside volumetric change was found to be 2.8% of the rate of volumetric articular wear and decreased with increasing liner size. Migrated acetabular components showed significantly higher rates of backside volumetric change plus screw-head indentations than those without migration. The backside volumetric change was at least ten times larger than finite-element simulation had suggested. In a stable acetabular component with well-anchored screws, the amount of backside wear should not cause clinical problems. Impingement of the screw-heads could produce more wear particles than those generated at the liner-shell interface. Because the rate of backside volumetric change is only 2.8% of the rate of volumetric articular wear and since creep is likely to contribute a significant portion to this, the debris generated by wear at the backside of the liner may not be sufficient to create a strong osteolytic response.

1 October 2017 in Gait & Posture
Verified
Journal Article
Closed access
MKMichèle Kläusler
Michèle Kläusler
BSBernhard Maria Speth
Bernhard Maria Speth
RBReinald Brunner
Reinald Brunner
Oren TiroshOren Tirosh
Oren Tirosh
CCCarlo Camathias
Carlo Camathias
Erich RutzErich Rutz
Erich Rutz