Unsteady flow is highly related to flow loss and aerodynamic performance degradation in the axial compressor. In this paper, the dynamic mode decomposition method was used to investigate in-depth flow structures and related evolutionary mechanisms of the internal flow field. Four main flow structures were observed through flow field decoupling: the oscillation of the tip leakage vortex (TLV) region, the circumferential migration of the leakage-induced vortex (LIV), the axial migration of the rear part of the leakage vortex (RLV), and the oscillation of the leading edge vortex (LEV). All of those four structures indicated the presence of internal high disturbance regions. The reconstruction of the dominant mode flow field revealed that the unsteady evolutionary mechanism of the flow field mainly consisted of two components: the axial evolution of the RLV and the circumferential evolution of the LIV. It was further revealed that the axial evolution of the RLV was the primary reason for the formation of low-energy fluid mass within the passage; under the influence of the “leading edge overflow,” the LIV eventually fused with the LEV. The blocking effect of the LEV led to the formation of a high oscillation region at the leading edge of the adjacent blade pressure surface, resulting in a synchronous moment between the emergence of the LIV and the LEV. The analysis of the two unsteady evolution mechanism components further supported TLV breakdown as the main cause of flow unsteadiness. This study laid the foundation for further accurate flow unsteadiness control.
Due to the nonlinear behavior of carbon dioxide properties at its critical point and the size effect of the supercritical carbon dioxide (S-CO2) centrifugal compressor, the stall causation mechanism differs between the S-CO2 centrifugal compressor and a conventional air compressor. The comprehension of the induced principle of the S-CO2 compressor rotating stall holds immense significance in enhancing stall margin and efficiency. This paper employs unsteady simulations to investigate the causes of the impeller rotating stall in the S-CO2 centrifugal compressor. The results show that the leading edge breakdown vortex (LEBV) formed by the tip leakage vortex (TLV) breakdown and the reverse flow in the passage are the reasons for blocking the passage and ultimately causing the rotating stall of the impeller. The migration motion of the LEBV not only induces the leading edge spillage phenomenon but also influences the intensity of the tip leakage flow (TLF) in adjacent passages, causing the propagation of the TLV breakdown phenomenon in the opposite direction to that of impeller rotation. The TLV undergoes intermittent breakdown in flow field, which is influenced by variations in TLF intensity. Additionally, there is a preceding process of breakdown-induced vortex formation and disappearance prior to TLV fragmentation.
Tip leakage vortex breakdown, as a strong unsteady phenomenon, is recognized as an important inducing factor for compressor rotating stall. In this study, a validated numerical simulation was conducted to analyze the impact and control mechanism of synthetic jets on the performance of a transonic compressor from the perspective of tip leakage vortex breakdown suppression. The results indicate that the baseline compressor's stall mechanism is as follows: under near stall condition, an unsteady flow process dominated by the tip leakage vortex breakdown exists in the blade tip. During this process, the flow capacity diminishes, leading to an emergence of leading-edge spillage, which subsequently triggers rotating stall. Synthetic jets yield considerable improvement in the compressor performance. In cases synthetic jets positioned at 25%, Cax achieves a maximum improvement of 10.97% in the stability margin, while synthetic jets placed at 50% Cax gives an improvement of peak efficiency by 0.82%. The mechanism for performance improvement is as follows: synthetic jets suppress the vortex breakdown, disrupt the inherent feedback mechanism in the tip flow field, and reduce the blockage within the passage, thereby achieving an extension of the stability margin. Specifically, during the injection phase, an induced vortex suppresses the breakdown of the tip leakage vortex, thereby reducing the blade loading. In the suction phase, the tip leakage flow is reduced, which weakens the recirculation zone and causes the interface between the mainstream and the leakage flow to shift downstream. This research provides technical support for the development and optimization of efficient, wide-margin compressors.
12 March 2020 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Unsteady flow in the blade tip region of modern axial flow compressors is one of the sources of loss, noise, and blade vibration. In some cases, it is potentially linked to stall inception. In this paper, the complex flow fields in the blade tip region of a transonic axial flow compressor rotor have been numerically investigated. The predicted results were validated by experimental data. Analyses of monitoring results of numerical probes showed that three typical flow characteristics occurred as the operating condition approached the stability limit: no flow fluctuation at the first operating point; flow fluctuation with high frequency and low amplitude at the second operating point; flow fluctuation with low frequency and high amplitude at the third operating point. Further analysis of the tip flow field showed that the evolution of the tip leakage vortex experienced three stages as the rotor was throttled. At the first stage, the TLV did not breakdown. At the second stage, a bubble-type breakdown of the tip leakage vortex occurred. At the third stage, a spiral-type breakdown of tip leakage vortex occurred. The current study demonstrated that the flow unsteadiness that appears within the test rotor was induced by the tip leakage vortex breakdown. Furthermore, with the transformation of the vortex breakdown form, the characteristic frequency and amplitude of the flow oscillation substantially changed.
16 November 2023 in Journal of Thermal Science and Engineering Applications
As the volume of natural draft wet cooling towers (NDWCTs) continues to increase, the influence of ambient air on the thermal performance of the NDWCT is not clear. Therefore, the main parameters such as gas–water ratio, circulating water temperature difference, and heat transfer in each zone were calculated, and the temperature field and humidity field were also investigated. The results showed that the ambient temperature had the greatest influence on the cooling capacity of the NDWCT and the increase of ambient temperature led the circulating water temperature difference decreases the most, which was 7.63 °C (74.15%). The increase of relative humidity and atmospheric pressure led to an increase in convective heat transfer and the decrease in evaporative mass transfer, while both the convective heat transfer and evaporative mass transfer reduced with the decreasing temperature. This study establishes a theoretical foundation for optimizing of the thermal performance and energy-saving design of NDWCTs.
The supercritical carbon dioxide (sCO2) centrifugal compressor, as a core component of the Brayton power cycle, faces a critical technical challenge in expanding its stable operating range to ensure stable operation of the cycle system. This investigation was conducted on a sCO2 centrifugal compressor to quantify the effects of the micro-blade on the performance and stability of the centrifugal compressor. The results demonstrate that adding the micro-blade profiles on the shroud side of the vaneless diffuser extends the compressor's stable operating range by 7.76%. The stability enhancement mechanism of the micro-blade primarily manifests in three aspects: first, after adding the micro-blade, the reverse flow region on the shroud side of the original diffuser is effectively truncated, reducing the reverse flow region on the shroud side. Second, on the pressure surface of the micro-blade, the airflow experiences counterclockwise circumferential deflection due to physical blockage from the micro-blade and moves toward the outlet of the diffuser under the action of the inlet vortex, which reduces the flow blockage. Third, low-energy fluid near the micro-blade forms a channel vortex and wake vortex that promote mixing between the main flow and low-energy fluid in the reverse flow region, enhancing the momentum of the low-energy fluid and strengthening its ability to resist adverse pressure gradients. The synergy of these effects reduces the accumulation of low-energy fluid on the shroud side of diffuser, improves the flow conditions in the diffuser passage, and consequently delays stall inception.