Rachel Conley

Ms. Rachel Conley

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
SGSahil Garg
Sahil Garg
PYPatrick Young
Patrick Young
CFChristopher Franquemont
Christopher Franquemont
RCRachel Conley
Rachel Conley
SGSanjitpal Gill
Sanjitpal Gill
Background: Interbody spinal fusion is a common surgical treatment for degenerative, traumatic, and deformity-related spinal pathologies. Despite advances in cage geometry and fixation strategies that improve alignment and early stability, reliable fusion remains limited by the mechanical and biological constraints of conventional interbody implant materials. Traditional titanium and polymer-based cages often fail to optimally balance load sharing, osteointegration, and biological activity within the mechanically demanding interbody environment. This narrative review examines the development and translational potential of 3D-printed interbody fusion devices, with emphasis on how additive manufacturing enables the integration of mechanical performance with biologically active scaffold design. Methods: A thorough literature review was performed to evaluate the evolution, design principles, material properties, and translational outcomes of three-dimensional (3D)-printed interbody fusion devices. Results: Additive manufacturing enables precise control over implant architecture, allowing for the fabrication of porous, lattice-based cages with tunable stiffness, optimized load sharing, and enhanced bone–implant integration. Preclinical and early clinical studies suggest that 3D-printed porous titanium cages may reduce subsidence, promote osteointegration, and improve fusion-related outcomes compared with conventional designs. Emerging evidence indicates that scaffold porosity, surface microtopography, and bioactive coatings influence macrophage polarization, angiogenesis, and osteogenic signaling. Polymeric and composite constructs, particularly hybrid designs incorporating surface functionalization, represent promising adjuncts, though clinical evidence remains limited. Conclusions: Three-dimensional printing represents a paradigm shift in interbody fusion device design. Continued translational research and longer-term clinical follow-up are required to validate efficacy and guide widespread clinical adoption.

9 April 2026 in North American Spine Society Journal (NASSJ)
Verified
Journal Article
Open access
SGSahil Garg
Sahil Garg
PYPatrick Young
Patrick Young
RCRachel Conley
Rachel Conley
CFChristopher Franquemont
Christopher Franquemont
SGSanjitpal S. Gill
Sanjitpal S. Gill
MGMichael A. Gallizzi
Michael A. Gallizzi
Long-construct fusions extending into the pelvis require durable sacropelvic fixation to withstand biomechanical forces. Traditional iliac screws provide strong fixation but are limited by wound complications, offset-connector requirements, and hardware prominence. S2-alar-iliac screws improve soft-tissue outcomes but may violate the sacroiliac joint, contribute to postoperative sacroiliac joint pain, and demonstrate variable fusion rates. With advances in robotics, medialized iliac trajectories may re-establish the advantages of iliac fixation while reducing complication profiles. This study evaluates the safety, accuracy, and perioperative outcomes of robotically placed iliac screws using a medialized, percutaneous technique. A retrospective review was performed of all patients who underwent robotically navigated iliac fixation between January 1, 2019, and January 1, 2025. Demographic, perioperative, and postoperative variables were collected, including sex, body mass index (BMI), ASA class, blood loss, surgery duration, complications, opioid use, visual analog scale pain scores, and primary versus revision status. Twenty-eight patients met inclusion criteria (9 primary, 19 revision). Mean age was 67.21 years, mean BMI 26.77, and mean ASA of 2.07. Mean blood loss was 81.61 mL. Mean visual analog scale scores improved by 2.11 points at 2 weeks. No surgical-site infections occurred. Two patients required revision for symptomatic hardware prominence, both with BMI<20. Two patients had 90-day complications unrelated to iliac fixation. Screw accuracy was 100%, with no cortical breaches or offset-connector requirements. Robotically placed medialized iliac screws appear to mitigate shortcomings of traditional iliac and S2-alar-iliac fixation. This technique avoids sacroiliac joint violation, minimizes wound complications, and provides precise fixation, representing a safe and effective technique. These findings support further investigation through prospective, comparative studies with longer follow-up to validate the long-term durability and generalizability of this approach.