Susana Merino-Caviedes

Dr. Susana Merino-Caviedes

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2013 in IEEE Transactions on Pattern Analysis and Machine Intelligence
Verified
Journal Article
Closed access
LCLucilio Cordero-Grande
Lucilio Cordero-Grande
SMSusana Merino-Caviedes
Susana Merino-Caviedes
SASantiago Aja-Fernández
Santiago Aja-Fernández
CACarlos Alberola-López
Carlos Alberola-López
This paper proposes a methodology for the joint alignment of a sequence of images based on a groupwise registration procedure by using a new family of metrics that exploit the expected sparseness of the temporal intensity curves corresponding to the aligned points. Therefore, this methodology is able to tackle the alignment of temporal sequences of images in which the represented phenomenon varies in time. Specifically, we have applied it to the correction of motion in contrast-enhanced first-pass perfusion cardiac magnetic resonance images. The time sequence is elastically registered as a whole by using the aforementioned family of multi-image metrics and jointly optimizing the parameters of the transformations involved. The proposed metrics are able to cope with dynamic changes in the intensity content of corresponding points in the sequence guided by the assumption that these changes allow for a sparse representation in a properly selected frame. Results have shown the statistically significant improvement in the performance of the proposed metric with respect to previous groupwise registration metrics for the problem at hand, which is especially relevant to correct for elastic deformations.

12 November 2018 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
SMSusana Merino-Caviedes
Susana Merino-Caviedes
LCLucilio Cordero-Grande
Lucilio Cordero-Grande
MPMaria Teresa Perez
Maria Teresa Perez
PCPablo Casaseca-De-La-Higuera
Pablo Casaseca-De-La-Higuera
MMMarcos Martin-Fernandez
Marcos Martin-Fernandez
CACarlos Alberola-Lopez
Carlos Alberola-Lopez
The Fast Marching method is widely employed in several fields of image processing. Some years ago a Multi-Stencil version (MSFM) was introduced to improve its accuracy by solving the equation for a set of stencils and choosing the best solution at each considered node. The following work proposes a modified numerical scheme for MSFM to take into account the variation of the local cost, which has proven to be second order. The influence of the stencil set choice on the algorithm outcome with respect to stencil orthogonality and axis swapping is also explored, where stencils are taken from neighborhoods of varying radius. The experimental results show that the proposed schemes improve the accuracy of their original counterparts, and that the use of permutation-invariant stencil sets provides robustness against shifted vector coordinates in the stencil set.

6 November 2013 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
SMSusana Merino-Caviedes
Susana Merino-Caviedes
LCLucilio Cordero-Grande
Lucilio Cordero-Grande
ARAna Revilla-Orodea
Ana Revilla-Orodea
TSTeresa Sevilla
Teresa Sevilla
MPM. Teresa Perez
M. Teresa Perez
CACarlos Alberola-López
Carlos Alberola-López
We propose a fully 3-D methodology for the computation of myocardial nonviable tissue transmurality in contrast enhanced magnetic resonance images. The outcome is a continuous map defined within the myocardium where not only current state-of-the-art measures of transmurality can be calculated, but also information on the location of nonviable tissue is preserved. The computation is done by means of a partial differential equation framework we have called multi-stencil streamline fast marching. Using it, the myocardial and scarred tissue thickness is simultaneously computed. Experimental results show that the proposed 3-D method allows for the computation of transmurality in myocardial regions where current 2-D methods are not able to as conceived, and it also provides more robust and accurate results in situations where the assumptions on which current 2-D methods are based-i.e., there is a visible endocardial contour and its corresponding epicardial points lie on the same slice-, are not met.

1 May 2012
Verified
Conference Paper
Closed access
LCL. Cordero-Grande
L. Cordero-Grande
SMSusana Merino-Caviedes
Susana Merino-Caviedes
XAX. Alba
X. Alba
RVR. M. Figueras i Ventura
R. M. Figueras i Ventura
AFA. F. Frangi
A. F. Frangi
CACarlos Alberola-López
Carlos Alberola-López
A procedure to fuse the information of short-axis cine and late enhanced magnetic resonance images is presented. First a coherent 3D reconstruction of the images is obtained by object-based interpolation of the information of contiguous slices in stacked short-axis cine acquisitions and by the correction of slice misalignments with the aid of a set of reference long-axis slices. Then, late enhanced stacked images are also interpolated and aligned with the anatomical information. Thus, the complementary information provided by both modalities is combined in a common frame of reference and in a nearly isotropic grid, which is not possible with existing fusion procedures. Numerical improvement is established by comparing the distances between unaligned and aligned manual segmentations of the myocardium in both modalities. Finally, a set of snapshots illustrate the improvement in the information overlap and the ability to reconstruct the gradient in the long-axis.

1 May 2008
Verified
Conference Paper
Closed access
SMSusana Merino-Caviedes
Susana Merino-Caviedes
MMMarcos Martin-Fernandez
Marcos Martin-Fernandez
A new interpolation method for 2 x 2 symmetric second-rank tensors is proposed. It uses a vector representation of tensors using its eigenvalues and the rotation angle of the major eigenvector with respect to a cartesian coordinate system. These characteristics are then linearly interpolated. Although it is not constricted to positive definite tensors, it preserves this property for tensors with nonnegative eigenvalues. We compare this technique with the matrix coefficient linear in terpolation. The experiments show that our technique improves the results.

1 August 2010 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
SMSusana Merino-Caviedes
Susana Merino-Caviedes
MPMaria Teresa Pérez
Maria Teresa Pérez
MMMarcos Martin-Fernandez
Marcos Martin-Fernandez
Classic geometric active contour algorithms have the limitation of segmenting the image into only two regions: background and object of interest. A new multiphase level set algorithm for the segmentation of two or more regions of interest is proposed. This algorithm avoids by construction the presence of overlapped and void regions and no additional coupling terms are required. In addition, the number of iterations needed to reach convergence is small. The algorithm has been tested against a state-of-the-art multiphase method on both simulated and real Magnetic Resonance Imaging (MRI) volumes with favorable results.