Chao Wu

Dr. Chao Wu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2020 in Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
CWChao Wu
Chao Wu
JDJia‐Yan Deng
Jia‐Yan Deng
CWChao Wu
Chao Wu
LTLun Tan
Lun Tan
DYDe‐Chao Yuan
De‐Chao Yuan
Objective: To evaluate the accuracy and safety of a combined 3D printed guide template (combined template) to assist iliosacral (IS) screw placement for sacral fracture and dislocation.Methods: A total of 37 patients, 24 men and 13 women, age from 22 to 68 years old, diagnosed with a sacral fracture and dislocation were involved in this study for retrospective analysis from January 2016 to February 2018. There were 19 patients in the template group (42 screws) and 18 patients in the conventional group (31 screws). In the combined template group, IS screw placement was assisted by a combined 3D printed template; in the conventional group, the IS screws were placed freehand under fluoroscopy. The accuracy of the IS screw placement was evaluated by comparing the screw angle and the location of the screw entry point between the actual and the simulated screw in the combined template group. The safety of the IS screw placement was evaluated by comparing the quality of the reduction, the grading of the screws, the operation time, and radiation exposure times between groups.Results: A total of 73 pedicle screws were placed in 37 patients: 42 screws (30 S1, 12 S2) in the combined template group and 31 screws (23 S1, 8 S2) in the conventional group. In the conventional group, 1 patient developed symptoms of L5 nerve stimulation. In the combined template group, the average operative time of each screw was 25.01 ± 2.90 min, with average radiation exposure times of 12.05 ± 4.00. In the conventional group, the average operative time of each screw was 46.24 ± 9.59 min, with an average radiation exposure time of 56.10 ± 6.75. There were significant differences in operation and radiation exposure times between groups. The rate of screw perforation was lower in the combined template group (2 of 42 screws, 0 at grade III and 2 at grade II) than in the conventional group (5 of 38 screws, 2 at grade III and 3 at grade III). In the combined template group, the mean distance between the entry points of the actual and simulated screws was 1.4 ± 0.9 mm, with a mean angle of deviation of 2.1° ± 1.6°. All patients were followed up once every 3 months and were followed for 3 to 12 months.Conclusion: Using the combined template to assist with the insertion of IS screws delivered good accuracy, less fluoroscopy and shorter operation time, and avoided neurovascular injury as a result of screw malposition.

13 July 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CWChao Wu
Chao Wu
JDJiayan Deng
Jiayan Deng
JPJian Pan
Jian Pan
CWChao Wu
Chao Wu
LTLun Tan
Lun Tan
DYDechao Yuan
Dechao Yuan
Objective: To analyse the anatomical conditions of transverse sacroiliac screw (TSS) about the S1 and S2 segments in order to develop and validate a locked navigational template for TSS placement. Methods: A total of 22 patients with sacral fractures were involved in this study from May 2018 to February 2019. Patients were divided into two groups according to the surgery procedure: locked template group and conventional group. The CT data of 90 normal sacra were analysed. The long axis, short axis and lengths of TSS, cancellous corridors were measured through 3D modelling. A patient-specific locked navigation template based on simulated screws was designed and 3D printed and then used to assist in TSS placement. The operative time and radiation times were recorded. The Matta criteria and grading score were evaluated. The entry point deviation of the actual screw placement relative to the simulated screw placement was measured, and whether the whole screw was in the cancellous corridor was ob`served. Results: S1 screws with a diameter of 7.3 mm could be inserted into 69 pelvises, and S2 screws could be inserted in all pelvises. The S1 cancellous corridor had a long axis of 25.44 ± 3.32 mm in males and 22.91 ± 2.46 mm in females, a short axis of 14.21 ± 2.19 mm in males and 12.15 ± 3.22 mm in females, a corridor length of 153.07 ± 11.99 mm in males and 151.11 ± 8.73 mm in females, and a proportional position of the optimal entry point in the long axis of the cancellous corridor of 35.96 ± 10.31% in males and 33.28 ± 7.2% in females. There were significant differences in the corridor long axis and corridor short axis between sexes (p < 0.05), and there were no significant differences in corridor length and proportional position of the optimal entry point in the long axis of the cancellous corridor between sexes (p > 0.05). The S2 cancellous corridor had a long axis of 17.58 ± 2.36 mm in males and 16 ± 2.64 mm in females, a short axis of 14.21 ± 2.19 mm in males and 13.14 ± 2.2 mm in females, a corridor length of 129.95 ± 0.89 mm in males and 136.5 ± 7.96 mm in females, and a proportional position of the optimal entry point in the long axis of the cancellous corridor of 46.77 ± 9.02% in males and 42.25 ± 11.95% in females. There were significant differences in the long axis, short axis and corridor length (p < 0.05). There was no significant difference in the proportional position of the optimal entry point in the long axis of the cancellous corridor (p > 0.05). A total of 20 transversal sacroiliac screws were successfully implanted into 10 patients with the assistance of locked navigation templates, and a total of 24 transversal sacroiliac screws were successfully implanted into 12 patients under C-arm fluoroscopy. There was a significant difference in surgical time (88 ± 14.76 min vs 102.5 ± 17.12 min, p = 0.048), radiation times (11.5 ± 1.78 vs 54.83 ± 6.59, p < 0.05) and screw grading between two groups (nineteen screws in grade 0, one screw in grade 1 and 0 screws in grade 2 vs fourteen screws in grade 0, 8 screws in grade 1 and 2 screws in grade 2, p = 0.005). All screw entry point deviations were shorter than the short axis of the cancellous corridor, and all screws were located completely within the cancellous corridor. Conclusion: Approximately 76% of males and females can accommodate screws with diameters of 7.3 mm in S1, and all persons can accommodate the same screw in S2. From the standard lateral perspective of the sacrum, the optimal entry point of the transverse screw is in the first 1/3 of the cancellous corridor for S1 and the centre of the cancellous corridor for S2. The patient-specific locked navigation template assisted in TSS placement with less operative time, less intraoperative fluoroscopy and higher safety of screw placement compared with traditional surgery.

4 March 2020 in Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
CWChao Wu
Chao Wu
JDJiayan Deng
Jiayan Deng
CWChao Wu
Chao Wu
LTLun Tan
Lun Tan
DYDechao Yuan
Dechao Yuan
Objective: To evaluate the accuracy of percutaneous pedicle screw (PPS) placement aided by a new drill guide template.Methods: The patients were divided into guide template group and conventional perspective group. In the conventional perspective group, the screws were placed by hand under fluoroscopy. In the guide template group, the screw placement was aided by a new drill guide template, and the drill guide template is designed according to the patient's ideal pedicle screw, but not based on skin morphology. The accuracy was evaluated by comparing the following parameters between the two groups: pedicle breach level, inclination angle deviation between the left and right screws, sagittal angle deviation between the left and right screws, and position deviation of the left and right screw entry points. The consistency of the postoperative screw angle and the corresponding guide template inclination angle was compared in the guide template group. The operative time, blood loss, and radiation times were compared between the groups.Results: A total of 146 patients (876 screws) were enrolled in our study including 79 (474 screws) in the guide template group and 67 (402 screws) in the conventional perspective group. The pedicle breach level in the guide template group (22/474) was significantly lower than that in the conventional perspective group (47/402) (P < 0.05). The position and direction deviations of the left and right screws in the guide template group (2.06 ± 1.02 mm, 1.23 ± 1.25 mm, 1.83° ± 1.49°) were significantly less than those in the conventional perspective group (5.33 ± 2.99 mm, 4.32 ± 3.25 mm, 2.87° ± 1.56°). The operation time, blood loss, and radiation times were significantly lower in the guide template group (80.49 ± 9.14 min, 50.42 ± 8.9 mL, 11.02 ± 2.44) than those in the conventional perspective group (108.1 ± 21.18 min, 71.7 ± 17.09 mL, 23.53 ± 4.54). There were no significant differences between the postoperative screw angle and the corresponding guide template angle in the guide template group.Conclusion: PPS placement aided by a new drill guide template yielded higher screw accuracy and less operative time, blood loss, and radiation exposure than traditional screw placement.

15 February 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TGTao Gao
Tao Gao
ZCZhi-Yu Chen
Zhi-Yu Chen
CWChao Wu
Chao Wu
XLXu Lin
Xu Lin
HHHai-Gang Hu
Hai-Gang Hu
CWChao Wu
Chao Wu
To explore the association between serum high-sensitivity C-reactive protein (HSCRP) levels and osteoarthritis (OA) in adults, providing new evidence for the diagnosis of adult OA. We selected data from the 2015–2018 National Health and Nutrition Examination Survey (NHANES) and conducted a cross-sectional study. Serum HSCRP levels were extracted from laboratory data, and OA patients were identified through questionnaire responses. Participants under the age of 20 and those with incomplete data were excluded. We used multivariable logistic regression models, restricted cubic spline (RCS) functions, and stratified analyses to study the association between serum HSCRP levels and osteoarthritis in adults. After screening, a total of 9,948 participants were included, among whom 1,196 were osteoarthritis patients, representing a prevalence rate of 12.02%. Multivariable logistic regression analysis, along with three adjusted models, showed a positive correlation between serum HSCRP levels and the occurrence of osteoarthritis in adults. Compared to the lowest HSCRP quartile, the highest quartile showed a 1.86-fold higher prevalence of OA (95% confidence interval: 1.55 ~ 2.23, P < 0.001). The restricted cubic spline analysis showed a significant increase in OA incidence with rising serum HSCRP levels (P < 0.05). Subgroup and forest plot analyses indicated a positive correlation between HSCRP levels and osteoarthritis across different subgroups, such as age, gender, hypertension status, activity status, drinking status, and Smoke status (P < 0.05). There is a positive correlation between serum HSCRP levels and the occurrence of osteoarthritis in adults. When a patient’s serum HSCRP level is elevated, the possibility of osteoarthritis should be considered.

20 March 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TGTao Gao
Tao Gao
ZCZhi-Yu Chen
Zhi-Yu Chen
CWChao Wu
Chao Wu
XLXu Lin
Xu Lin
HHHai-Gang Hu
Hai-Gang Hu
CWChao Wu
Chao Wu
To explore the relationship between the Body Roundness Index (BRI) and the prevalence of osteoarthritis (OA) and rheumatoid arthritis (RA) among American adults, providing new insights for identifying OA and RA in adults. We analyzed data from the National Health and Nutrition Examination Survey (NHANES) 2015–2023 and conducted a large cross-sectional study. BRI was calculated based on body measurements, while OA and RA cases were identified through questionnaires. Participants under 20 years of age and those with incomplete data were excluded. Weighted multivariate logistic regression models, restricted cubic spline (RCS) functions, and stratified analyses were used to assess the relationship between BRI levels and the prevalence of OA and RA in American adults. To further evaluate BRI’s diagnostic potential for OA and RA, receiver operating characteristic (ROC) curves were employed to analyze and calculate the area under the curve (AUC). After screening, 17,544 participants were included, with 2,382 cases of OA (13.58%) and 987 cases of RA (5.63%). Multivariate logistic regression analyses showed a positive correlation between BRI and OA prevalence in American adults in both the unadjusted and adjusted models. A similar correlation was observed for RA in the unadjusted and partially adjusted models (P < 0.001), but the fully adjusted model showed no significant association between BRI and RA (P > 0.05). In the unadjusted model, the prevalence of OA in the highest BRI quartile was 3.47 times than that of the lowest quartile (95% CI: 2.84, 4.24, P < 0.001). Even in the fully adjusted model, the prevalence of OA in the highest BRI quartile remained 1.46 times higher than that of the lowest quartile (95% CI: 1.02, 2.08, P < 0.05). RCS curves demonstrated a non-linear relationship between BRI and both OA and RA, with a significant increase in prevalence as BRI levels rose (P < 0.001). Subgroup analyses and forest plots indicated a positive correlation between BRI and OA and RA in most subgroups (P < 0.05). ROC curves showed that BRI had a better predictive ability for OA and RA risk compared to BMI. There is a significant positive correlation between BRI and the prevalence of OA and RA in American adults, especially OA. Maintaining a lower BRI may help prevent the onset of OA and RA.

7 April 2021 in Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
CWChao Wu
Chao Wu
JDJia‐Yan Deng
Jia‐Yan Deng
CWChao Wu
Chao Wu
BZBo‐Fang Zeng
Bo‐Fang Zeng
HHHai‐Gang Hu
Hai‐Gang Hu
QWQin Wei
Qin Wei
Objective: To develop and validate the efficacy of a 3D‐printed screw‐rod auxiliary system for unstable atlas fractures.Methods: This research is a retrospective analysis, and a total of 14 patients, including 11 males and three females, were enrolled in our hospital from January 2017 to March 2019 who underwent occipitocervical fusion assisted by the 3D‐printed screw‐rod auxiliary system were reviewed, and with an average age of 53.21 ± 14.81 years, an average body mass index (BMI) of 23.61 ± 1.93 kg/m2. The operation time, blood loss and radiation times during the operation were recorded. The maximum fracture displacement values of pre‐ and post‐operation were measured based on CT imaging. All screw grades were evaluated after surgery. The occipital‐cervical 2 (O‐C2) angle and occipitocervical inclination (OCI) angle of pre‐operation, post‐operation and the last following‐up were measured. The dysphagia scale 3 months after surgery and at the last follow‐up, the Neck Disability Index (NDI) 3 months after surgery and at the last follow‐up were assessed.Results: All patients were completed the surgery successfully. There was no patient with severe dysphagia or aggravation of nerve injury. The follow‐up was from 12 to 14 months, and with an average of 12.5 months. The average surgery time, average blood loss and average radiation times for the 14 patients were 112.14 min, 171.43 mL and 5.07 times, respectively. There was a significant difference in maximum fracture displacement between pre‐ and post‐operation values (P < 0.05). A total of 56 screws were inserted in 14 patients, among them, three screws were classified as grade 1, and the other screws were classified as grade 0. There was a significant difference in the O‐C2 between pre‐operation and 3 days after operation (P = 0.002); There was a significant difference in OCI angles between pre‐operation and 3 days after operation (P < 0.05); there was no significant difference in the O‐C2 or OCI angle between 3 days after the operation and the last follow‐up (P = 0.079; P = 0.201). The dysphagia scales of two patients were assessed as mild at 3 months after surgery, and the others were assessed as normal at 3 months after surgery. All patients' dysphagia scores returned to normal at the last follow‐up. The average NDI and average neck Visual Analogue Scale (VAS) scores at the last follow‐up were 2.53 and 8.41, respectively.Conclusion: It can objectively restore the OCI to normal with few post‐operative complications under the assistance of a screw‐rod auxiliary system to perform occipitocervical fusion for unstable atlas fractures and atlantooccipital joint instability.