Lu Ma

Lu Ma

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2017 in IEEE Sensors Journal
Verified
Journal Article
Open access
LMLu Ma
Lu Ma
DMDominic McCann
Dominic McCann
AHAndrew Hunt
Andrew Hunt
For oil fields producing high fractions of water, it is critical to be able to accurately meter the water volumetric flowrate for production allocation and field life optimization. This paper reports the measurement principles and experimental results of a multiphase flow meter prototype, capable of non-intrusively measuring the water volumetric flowrate in a multiphase flow. This research prototype is based on a novel concept of combining two tomographic systems-magnetic induction tomography and electromagnetic velocity tomography-for measuring the cross-sectional volumetric fraction and the local axial velocity of the water phase, respectively. The fundamental principles and imaging capability of each technique are shown. First impressions of the prototype performance are demonstrated using experimental data from an in-house flow loop. The challenges and potential improvements are also addressed.

1 October 2020 in Journal of Natural Gas Science and Engineering
Verified
Journal Article
Closed access
YAYessica Arellano-Prieto
Yessica Arellano-Prieto
AHAndrew Hunt
Andrew Hunt
OHOlivier Haas
Olivier Haas
LMLu Ma
Lu Ma

4 May 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LMLu Ma
Lu Ma
MSManuchehr Soleimani
Manuchehr Soleimani
The structural health monitoring of ferromagnetic materials is essential for controlling product quality. This paper presents the first known characterisation, utilising magnetic induction spectroscopy, of the magnetic permeability of ferromagnetic materials, a property that can facilitate such monitoring. Magnetic induction coils are interrogated by a sweep of excitation frequencies in the range of 1–100 kHz, with amplitudes of induced voltages collected from both non-magnetic and ferromagnetic specimens, and their associated spectral permeability imaged. The reconstructed images show that magnetic permeability can be reconstructed using frequency difference imaging in the investigated frequency range. As such, the relative magnetic permeability of a ferromagnetic specimen can be reconstructed without needing a time difference measurement. This provides a robust imaging approach for the material characterisation of ferromagnetic specimens.

7 June 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LZLiying Zhu
Liying Zhu
LMLu Ma
Lu Ma
YLYi Li
Yi Li
YYYunjie Yang
Yunjie Yang
MZMaomao Zhang
Maomao Zhang
Benefiting from the ability to image the permittivity distribution of dielectric materials, electrical capacitance tomography (ECT) has been applied for multiphase flow metering for decades as a contactless method. However, the water-continuous flow brings challenges for ECT since the conductivity in water makes ECT fail to reconstruct the distribution. Therefore, complex-valued ECT (CV-ECT) is introduced to image both permittivity and conductivity distribution based on complex-valued capacitance measurements using the same sensor head of ECT. Different from conventional ECT, the investigation of excitation frequency and linearization point selection is vital for CV-ECT, as the conductivity information is coupled with permittivity and frequency. An eight-electrode CV-ECT system was set up to obtain measurements both in simulations and experiments. The measurements on different phantoms over different excitation frequencies were conducted, and the images were reconstructed to elaborate the selection of the linearization point and excitation frequency range.

13 November 2019 in Measurement Science and Technology
Verified
Journal Article
Closed access
YAYessica Arellano-Prieto
Yessica Arellano-Prieto
AHAndrew Hunt
Andrew Hunt
OHOlivier Haas
Olivier Haas
HAHafiz Ahmed
Hafiz Ahmed
LMLu Ma
Lu Ma
Magnetic induction tomography (MIT) is an imaging technology that measures changes in the electric properties of a sample located within the imaging region. Measurement of low conductivity contrasts such as biological tissue or ionized water flow in pipelines requires highly accurate systems due to the small amplitude of the measured signals. Optimisation of the sensors results in enhanced MIT performance. Geometric characteristics of MIT sensors impact the intensity of the electromagnetic field, and the inductive coupling between (a) the sensors and (b) the sensors and the medium. Three correlation models are derived to help developers predict the relative performance of MIT systems for a given set of coil characteristics. Bivariate and multiple regression analyses are performed on a dataset from finite element method simulations to validate the relationship between the sensor geometry and three performance parameters for a given set of uniform background distributions. Correlation models are provided for prediction of induced voltage level, eddy currents and system sensitivity relative to the geometric characteristics of the sensors. The performance of the computed models is validated using a dataset of 180 coil designs and four uniform electrical conductivity distributions. Predictions from the developed correlations are compared to reference data from simulations and experiments. Errors estimated for the predicted performance parameters together with the variance for each correlation are presented. The predicted data fitted the reference values within ±15%, showing reasonable accuracy of the models and a balanced variance-bias trade-off. It was found that the performance of MIT systems is largely affected by the coil dimensions and the number of turns, as well as by the coil shape and wire diameter to a lesser degree.

5 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XBXinyu Bi
Xinyu Bi
MSManuchehr Soleimani
Manuchehr Soleimani
LMLu Ma
Lu Ma
Helmholtz coils are widely used to generate homogeneous magnetic fields. Various parameters influence the magnetic field strength and homogeneity, including coil shape, size, spacing, winding layers, winding turns, and axial and radial gaps between windings. Previous researches have partially examined these parameters through local sensitivity analysis, where each parameter is varied independently while others are held constant. However, such studies often have limited applicability due to the interdependence of parameters including coil size, spacing, and windings. This work employs a new global sensitivity analysis, Reciprocal Optimum Solution, to investigate the interconnections between these parameters and their effects on magnetic flux density and field homogeneity. This approach eliminates the need to manually optimize variable ranges and mitigates the issues of randomness, uncertainty, and slow convergence by producing both deterministic formulas and a blueprint for designing Helmholtz coils with homogeneous magnetic fields. Using this method, we produced open-source Helmholtz coils development software. This enables users to obtain design parameters for Helmholtz coils for a required homogeneous magnetic field domain, when provided either its cross-sectional diameter or the coil spacing required for the device.