To assess the performance of urban drainage systems in metropolitan areas in southern China, 12 urban drainage systems, including nine separate sewer systems (SSSs) and three combined sewer systems (CSSs) were monitored from 2008 to 2012 in Shanghai and Hefei. Illicit connection rates of SSS were determined. The results indicate that serious illicit connections exist for most SSSs. Annual volume balance for two SSSs with serious illicit connection was assessed with a hydraulic model to determine the dry weather overflow volume. Although interception facilities have been implemented in SSSs, for some systems with serious illicit connections, a considerable volume of dry weather overflow still existed. Combined with monitoring of dry/wet weather flow quality, the pollutant load caused by wet/dry weather overflow was quantified. The results revealed that there was no obvious advantage of having SSSs over CSSs in terms of pollutant control. The serious pollution caused by illicit connections and insufficient management occurs in many cities in China. The performance assessment of separate and CSSs in Shanghai and Hefei provides important lessons and practical experience that can be applied to the construction and management of urban drainage system in China as well as other developing countries.
27 April 2019 in Environmental Science and Pollution Research
In order to investigate the characterization of runoff in storm sewer from various urban catchments, three monitoring systems at different spatial scales have been installed separately. They have been held since July 2010 in urban area of Beijing (China). The monitoring data revealed that chemical oxygen demand (COD), total suspended solids (TSS), total nitrogen (TN), total phosphorus (TP), and NH3-N values significantly exceed the Class V surface water quality standard developed by Ministry of Environmental Protection of the People's Republic of China (MEP). A surface solids buildup and wash off model for small watershed was adopted to analyze and discuss the process of a runoff pollutant discharge. More than a half of pollutant parameters presented a good fit to the model. However, a slightly worse-fit to the wash off model appeared in less than half of the data. Due to the influence of sewer sediments, sewer system characteristics, catchment characteristics, and other reasons, first flush was seldom observed in storm sewer runoff from these three survey areas. Meanwhile, the correlation between TSS and any other pollutant was analyzed according to cumulative load of pollutants in runoff events. An event mean concentrations (EMCs) approach was adopted to quantify the pollution of runoff. EMCs of various pollutants in storm sewer runoff between different rainfall events were slightly higher than the typical values observed in similar areas at home and abroad, according to other studies reported in literature. Based on quantitative analysis, it can be concluded that urban non-point source pollution is recognized as the major causes of quality deterioration in the receiving water bodies. This is after the point source pollution has been controlled substantially in Beijing. An integrated strategy, which combines centralized and decentralized control, along with the conditions of meteorology, hydrology, urban planning, existing drainage system, etc., will be an effective and economic approach to urban runoff pollution control.
Bioretention is an effective technology for urban stormwater management, but the nutrient removal in conventional bioretention systems is highly variable. Thus, a pilot bioretention column experiment was performed to evaluate the nutrient control of systems with commercial activated carbon and river sediment-derived biochar. Significant chemical oxygen demand (COD) and total phosphorus (TP) leaching were found with the addition of activated carbon and biochar, but total nitrogen (TN) leaching was significantly improved when activated carbon was used as the medium. During a semi-synthetic runoff experiment, the bioretention systems containing two types of fluvial biochar showed relatively better COD and TN control (average mass removal efficiencies and cumulative removal efficiencies) than commercial activated carbon. However, the average TP mass removal efficiency with commercial activated carbon (95% ± 3%) was significantly higher than biochar (48% ± 20% and 56 ± 14%). The addition of biochar in the media increased the nitrogen removal efficiency, and the addition of activated carbon significantly increased the phosphorous removal efficiency. Therefore, both biochar and activated carbon are effective materials for bioretention, and fluvial biochar provides an alternative approach to comprehensively utilize river sediment.
First flush is a common phenomenon in urban runoff pollution. Typical cement roof and asphalt road runoff in Beijing, China were monitored for 2 years. Based on the M(v) curve, the suspended solids (SS), chemical oxygen demand (COD), total phosphorus (TP) and particulate phosphorus in cement roof runoff presented a stronger first flush than those in asphalt road runoff. The first flush volume (VFF) of SS, COD, total nitrogen (TN) and TP in asphalt road runoff differed slightly from the cement roof. There were also differences in the first flush assessment depending on which method was used. We proposed a new method based on the runoff depth versus pollutant cumulative mass curve. According to the national standards in China (VFF = 3 mm), various masses of different pollutants, such as 91.42 ± 9.80% (cement roof) and 78.49 ± 19.41% (asphalt road) of SS and 86.85 ± 13.54% (cement roof) and 72.80 ± 25.79% (asphalt road) of COD, can be effectively controlled, but our mass control efficiencies were 55.91%–66.65% when VFF = 1 mm. The new method proposed in this study provides an alternative approach for assessing runoff pollution control efficiency of different VFF.