A 1D plug flow model suitable for describing the CO2 conversion into CO in microwave plasma reactors is proposed. The model is applied together with the Antwerp data set for the CO2 reaction kinetics to calculate parameter scans for a realistic experimental set up. The energy re-distribution pathways in the model calculations are analyzed. The analysis shows that despite the input power being initially deposited mainly into vibrational states the fast vibrational-translational (VT) transfer leads to dissociation of CO2 predominantly via the thermal quenching mechanism. Solutions with mitigated VT-losses can be obtained by increasing the specific input power–power per unit volume. In this regime the energy efficiency starts to be constrained by reverse processes.
The problems related to the spectral line-shape formation in the scrape of layer (SOL) in fusion reactor plasma for typical observation chords are considered. The SOL plasma is characterized by the relatively low electron density (1012–1013 cm−3) and high temperature (from 10 eV up to 1 keV). The main effects responsible for the line-shape formation in the SOL are Doppler and Zeeman effects. The main problem is a correct modeling of the neutral atom velocity distribution function (VDF). The VDF is determined by a number of atomic processes, namely: molecular dissociation, ionization and charge exchange of neutral atoms on plasma ions, electron excitation accompanied by the charge exchange from atomic excited states, and atom reflection from the wall. All the processes take place step by step during atom motion from the wall to the plasma core. In practice, the largest contribution to the neutral atom radiation emission comes from a thin layer near the wall with typical size 10–20 cm, which is small as compared with the minor radius of modern devices including international test experimental reactor ITER (radius 2 m). The important problem is a strongly non-uniform distribution of plasma parameters (electron and ion densities and temperatures). The distributions vary for different observation chords and ITER operation regimes. In the present report, most attention is paid to the problem of the VDF calculations. The most correct method for solving the problem is an application of the Monte Carlo method for atom motion near the wall. However, the method is sometimes too complicated to be combined with other numerical codes for plasma modeling for various regimes of fusion reactor operation. Thus, it is important to develop simpler methods for neutral atom VDF in space coordinates and velocities. The efficiency of such methods has to be tested via a comparison with the Monte Carlo codes for particular plasma conditions. Here a new simplified method for description of neutral atoms penetration into plasma is suggested. The method is based on the ballistic motion of neutrals along the line-of-sight (LoS) in the forward–back approximation. As a result, two-dimensional distribution functions, dependent on the LoS coordinate and the velocity projection on the LoS, and responsible for the Doppler broadening of the line shape, are calculated. A comparison of the method with Monte Carlo calculations allows the evaluation of the accuracy of the ballistic model. The Balmer spectral line shapes are calculated for specific LoS typical for ITER diagnostics.
Predictions of impurity fluxes are required for design analysis of the ITER optical diagnostics. In the present paper a simplified model is proposed for calculation of the neutral impurity fluxes on the recessed surfaces which are not in direct contact with plasma. The method is based on the Monte-Carlo simulation of the neutral particles transport in prescribed and fixed plasma background. The plasma parameters are projected from experimental observations, scalings and ITER modelling results. Blobs are approximated as stationary hot species. Results of 2D simulations with toroidally uniform wall and of the ‘2.5D model’ are presented. In this latter the 3D geometry of ports is implemented, but details of the incident ion flux distribution on the first wall panels are neglected. The calculated worst case gross deposition rate of Be in the middle of the port plug faces reaches almost 0.1 nm s−1. At the same time, the obtained Be erosion to deposition ratio at those locations is always larger than 5, indicating high probability of net erosion conditions there.
1 September 2022 in Plasma Sources Science and Technology
Non-equilibrium vibrational dissociation CO2 → CO + O at translational–rotational temperatures T ⩽ 1200 K is investigated with semi-empiric and computational models. The governing parameter has been introduced, where Q is the specific volumetric power coupled into vibrational states and n0 is the initial number density of CO2. It has been shown that the non-equilibrium vibrational process can only be triggered when exceeds some critical value determined by the speed of vibrational relaxation. Simple semi-empiric calculations are backed by the state-to-state simulations of the CO2 vibrational kinetics in two-modes approximation performed for conditions of microwave sustained gas discharges. The vibrational kinetics model is benchmarked against the experimental vibrational relaxation times as well as the shock tube data on the rate of the process CO2 + M → CO + O + M for M = Ar and literature data for M = CO2. At T = 300 K the estimated W m3 or 35 W (m−3 Pa−2) (p is the gas pressure). is found to always increase with increased T.