Guangyuan Song

Dr. Guangyuan Song


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2023 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
GSGuangyuan Song
Guangyuan Song
XGXu-Nan Guo
Xu-Nan Guo
JYJing Yao
Jing Yao
ZLZhi-Nan Lu
Zhi-Nan Lu
JXJia-Hong Xie
Jia-Hong Xie
JHJie Han
Jie Han
Aim: To evaluate the expression profile of long non-coding RNAs (lncRNAs) in calcific aortic valve disease (CAVD) and explore their potential mechanism of action. Methods: The gene expression profiles (GSE153555, GSE148219, GSE199718) were downloaded from the Gene Expression Omnibus (GEO) database and FastQC was run for quality control checks. After filtering and classifying candidate lncRNAs by differentially expressed genes (DEGs) and weighted co-expression networks (WGCNA) in GSE153555, we predicted the potential cis- or trans-regulatory target genes of differentially expressed lncRNAs (DELs) by using FEELnc and established the competitive endogenous RNA (ceRNA) network by miRanda, more over functional enrichment was analyzed using the ClusterProfiler package in R Bioconductor. The hub cis- or trans-regulatory genes were verified in GSE148219 and GSE199718 respectively. Results: There were 340 up-regulated lncRNAs identified in AS group compared with the control group (|log2Fold Change| ≥ 1.0 and Padj ≤ 0.05), and 460 down-regulated lncRNAs. Based on target gene prediction and co-expression network construction, twelve Long non-coding RNAs (CDKN2B-AS1, AC244453.2, APCDD1L-DT, SLC12A5-AS1, TGFB3, AC243829.4, MIR4435-2HG, FAM225A, BHLHE40-AS1, LINC01614, AL356417.2, LINC01150) were identified as the hub cis- or trans-regulatory genes in the pathogenesis of CAVD which were validated in GSE148219 and GSE19971. Additionally, we found that MIR4435-2HG was the top hub trans-acting lncRNA which also plays a crucial role by ceRNA pattern. Conclusion: LncRNAs may play an important role in CAVD and may provide a new perspective on the pathogenesis, diagnosis, and treatment of this disease. Further studies are required to illuminate the underlying mechanisms and provide potential therapeutic targets.

15 October 2022 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
JYJing Yao
Jing Yao
ZLZhi-Nan Lu
Zhi-Nan Lu
TMThomas Modine
Thomas Modine
HJHasan Jilaihawi
Hasan Jilaihawi
NPNicolo Piazza
Nicolo Piazza
GSGuangyuan Song
Guangyuan Song
Background: Success rate of transcatheter aortic valve replacement (TAVR) in aortic regurgitation (AR) patients is relatively low on account of the absence of calcified anchoring structures. Morphological classification and corresponding TAVR strategies for AR are lacking yet. Methods: The AURORA study is a prospective, multicenter, single-arm cohort study to evaluate the safety and efficacy of transfemoral TAVR for severe AR in patients with high or prohibitive risk for surgery. Patients who are ≥ 65 years and diagnosed with severe pure AR as defined by the Echocardiographic Core Laboratory will be consecutively enrolled for further multidetector computed tomography (MDCT) scanning and multiplanar analyses. Based on a new anatomical classification and dual anchoring theory, patients will be classified into 4 types according to the level of the anchoring area. Types 1, 2 and 3 (at least 2 anchoring areas) will undergo the TAVR procedure with a domestic Chinese self-expanding valve (VitaFlow Valve, MicroPort, Shanghai, China), whereas type 4 (0 or 1 anchoring area) patients will be considered unsuitable for TAVR and will receive medical treatment. Our goal is to recruit 100 patients to account for 10% missing data or loss of patients to follow-up. Procedural, 30-day, 6-month and 12-month outcomes will be assessed according to Valve Academic Research Consortium-3 criteria. Discussion: The AURORA study will establish a new AR anatomical classification based on dual anchoring theory through MDCT multiplanar measurement and assess the safety and efficacy of TAVR guided by this new classification and strategy in AR patients. Trial registration: This Study was registered at Chinses Clinical Trial Registry. The registration number: ChiCTR2200055415; The date of registration: 9, January 2022; The URL of the registration: http://www.chictr.org.cn/showproj.aspx?proj=141209.

15 May 2024 in ESC Heart Failure
Verified
Journal Article
Open access
RLRan Liu
Ran Liu
ZFZhaolin Fu
Zhaolin Fu
ZJZhengming Jiang
Zhengming Jiang
YYYunfeng Yan
Yunfeng Yan
JYJing Yao
Jing Yao
GSGuangyuan Song
Guangyuan Song
The efficacy and safety of new-generation devices (NGDs) for severe aortic regurgitation (AR) have mostly been based on single-arm studies with limited sample sizes. Our goal was to summarize the current evidence on NGDs and compare the safety and efficacy of ‘off-label’ and ‘on-label’ devices in NGDs. We searched MEDLINE, Embase, Cochrane Library, and Scopus for articles on transcatheter aortic valve replacement in patients with AR. A total of 31 studies that included 1851 patients were identified through April 2023. Among these, 1067 (57.6%) patients received treatment with ‘on-label’ devices (JenaValve and J-Valve). For NGDs, the total device success rate at 30 days was 94.5% (on-label: 97.8%, off-label: 89.9%; P < 0.001), the all-cause mortality was 4.2% (on-label: 2.6%, off-label: 5.1%; P = 0.006), permanent pacemaker implantation (PPI) was 8.8% (on-label: 6.9%, off-label: 18.4%; P < 0.001), and the rate of greater-than-mild paravalvular leak (PVL) was 1.2% (on-label: 0.9%, off-label: 3.8%; P = 0.003). On-label devices showed significantly better safety and efficacy in terms of the success rate, PPI, greater-than-mild PVL, and 30 day mortality than off-label devices.

15 May 2024 in eClinicalMedicine
Verified
Journal Article
Open access
SCSanshuai Chang
Sanshuai Chang
ZJZhengming Jiang
Zhengming Jiang
XLXinmin Liu
Xinmin Liu
YTYida Tang
Yida Tang
MBMing Bai
Ming Bai
GSGuangyuan Song
Guangyuan Song
The permanent pacemaker (PPM) implantation and pacemaker dependency rates after transcatheter aortic valve replacement (TAVR) are highly variable as some of the conduction disturbances are reversible. It remains poorly investigated how to optimise temporary pacing in these patients. This study aimed to explore the potential reduction in the PPM implantation rate using temporary-permanent pacemaker (TPPM) as a 1-month bridge. This is a prospective, multicentre, single-arm, observational study. Consecutive patients undergoing TAVR from March 1, 2022 to March 1, 2023 in 13 tertiary hospitals in China were screened. Patients who developed high-degree atrioventricular block, complete heart block, or first-degree atrioventricular block plus new onset left bundle branch block during the TAVR procedure or within 1 month after TAVR were included to receive TPPM. Patients with pre-existing PPM implantation or indications for PPM implantation before the TAVR procedure were excluded. Patients with TPPM were monitored to determine whether the conduction disturbances persisted or recovered. The primary endpoint was the rate of freedom from indications for PPM implantation 1 month after TAVR. This study is registered with ChiCTR, ChiCTR2200057931. Of 688 patients who have undergone TAVR, 71 developed conduction disturbance and met the inclusion criteria, 1 patient withdrew due to noncompliance, 70 patients received TPPM and completed follow-up. There were 41 (58.6%) men and 29 (41.4%) women in the study, with a mean age of 74.3 ± 7.3 years. At 1 month follow-up, 75.7% (53/70) of the patients with TPPM did not require PPM implantation. For 688 patients who have undergone TAVR, the rate of PPM implantation at 1 month was 2.47% (17/688, 95% CI 1.55%-3.92%), representing a significant reduction in self-comparison with the rate at 48 h after TPPM (2.47% vs. 8.28% [95% CI 6.45%-10.58%], P < 0.0001). Similar results were obtained in the subgroup analysis of patients with HAVB/CHB. Multivariate analysis revealed the baseline PR interval, difference between the membranous septum length and implantation depth, and timing of postprocedural conduction disturbance occurrence were independent predictors of freedom from indications for PPM implantation at 1 month after TAVR. Using TPPM as a 1-month bridge allows for a buffer period to distinguish whether conduction disturbances are reversible or persistent, resulting in a significant reduction in the PPM implantation rate after TAVR when compared with the current strategy. However, this is an observational study, the results need to be confirmed in a randomized trial. Beijing Science and Technology Plan 2022 from Beijing Municipal Science & Technology Commission.

25 January 2023 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
SCSanshuai Chang
Sanshuai Chang
XLXinmin Liu
Xinmin Liu
ZLZhi-Nan Lu
Zhi-Nan Lu
JYJing Yao
Jing Yao
CYChengqian Yin
Chengqian Yin
GSGuangyuan Song
Guangyuan Song
Background: Limited data exist on the use of temporary permanent pacemaker (TPPM) to reduce unnecessary PPM in patients with high-degree atrioventricular block (HAVB) after transcatheter aortic valve replacement (TAVR).Objectives: This study aims to determine the feasibility of TPPM in patients with HAVB after TAVR to provide prolonged pacing as a bridge.Materials and methods: One hundred and eleven consecutive patients undergoing TAVR were screened from August 2021 to June 2022. Patients with HAVB eligible for PPM were included. TPPM were used in these patients instead of conventional temporary pacing or early PPM. Patients were followed up for 1 month. Holter and pacemaker interrogation were used to determine whether to implant PPM.Results: Twenty one patients met the inclusion criteria for TPPM, of which 14 patients were third-degree AVB, 1 patient was second-degree AVB, 6 patients were first degree AVB with PR interval > 240 ms and LBBB with QRS duration > 150 ms. TPPM were placed on the 21 patients for 35 ± 7 days. Among 15 patients with HAVB, 26.7% of them (n = 4) recovered to sinus rhythm; 46.7% (n = 7) recovered to sinus rhythm with bundle branch block. The remains of 26.7% patients (n = 4) still had third-degree AVB and received PPM. For patients with first-degree AVB and LBBB, PR interval shortened to < 200 ms in all 6 patients and LBBB recovered in 2 patients. TPPM were successfully removed from all patients and no procedure-related adverse events occurred.Conclusion: TPPM is reliable and safe in the small sample of patients with conduction block after TAVR to provide certain buffer time to distinguish whether a PPM is necessary. Future studies with larger sample are needed for further validation of the current results.

20 December 2022 in Chinese Medical Journal
Verified
Journal Article
Open access
GNGuannan Niu
Guannan Niu
WAWalid Ben Ali
Walid Ben Ali
MWMoyang Wang
Moyang Wang
HJHasan Jilaihawi
Hasan Jilaihawi
HZHaitong Zhang
Haitong Zhang
GSGuangyuan Song
Guangyuan Song
Background: The study aimed to describe the aortic valve morphology in Chinese patients underwent transcatheter aortic valve replacement (TAVR) for symptomatic severe aortic stenosis (AS), and the impact of sizing strategies and related procedural outcomes. Methods: Patients with severe AS who underwent TAVR were consecutively enrolled from 2012 to 2019. The anatomy and morphology of the aortic root were assessed. “Downsize” strategy was preformed when patients had complex morphology. The clinical outcomes of patients who performed downsize strategy were compared with those received annular sizing strategy. The primary outcome was device success rate, and secondary outcomes included Valve Academic Research Consortium-3 clinical outcomes variables based on 1-year follow-up. Results: A total of 293 patients were enrolled. Among them, 95 patients (32.4%) had bicuspid aortic valve. The calcium volume (Hounsfield Unit-850) of aortic root was 449.90 (243.15–782.15) mm3. Calcium is distributed mostly on the leaflet level. Downsize strategy was performed in 204 patients (69.6%). Compared with the patients who performed annular sizing strategy, those received downsize strategy achieved a similar device success rate (82.0% [73] vs. 83.3% [170], P = 0.79). Aortic valve gradients (downsize strategy group vs. annular sizing group, 11.28 mmHg vs. 11.88 mmHg, P = 0.64) and percentages of patients with moderate or severe paravalvular regurgitation 2.0% (4/204) vs. 4.5% (4/89), P = 0.21) were similar in the two groups at 30 days after TAVR. These echocardiographic results were sustainable for one year. Conclusions: Chinese TAVR patients have more prevalent bicuspid morphology and large calcium volume of aortic root. Calcium is distributed mostly on the leaflet level. Compare with annular sizing strategy, downsize strategy provided a non-inferior device success rate and transcatheter heart valve hemodynamic performance in self-expanding TAVR procedure.