This article presents the results of the exploratory study on indoor air quality in existing dwellings with traditional ventilation systems based on natural ventilation. A preliminary study of the most representative typology of the Spanish housing stock has been conducted and, based on it, twelve dwellings located in Madrid have been monitored in different periods. Monitored indoor air quality has been compared to that required in the regulations in Spain, the Código Técnico de la Edificación (Technical Building Code). According to the results of the research, 50 % of the monitored dwellings do not comply with the CO2-based air quality quantification offset in the regulations. Such non-compliance is primarily caused by high CO2 concentrations in winter, especially in bedrooms. These high concentrations and their seasonality are attributed to the interference of the occupant’s behaviour, influenced by weather conditions, that is affecting the efficiency of the existing natural ventilation systems.
One of the solutions used to limit radon in buildings is to install membrane-type barriers, a costly solution for large surfaces. As concrete often forms the building envelope with the ground, it is interesting to investigate its performance as a barrier, i.e. its radon exhalation, which depends on the radon diffusion coefficient and thickness. Experimentally obtaining the radon diffusion coefficient in concrete is complicated, so it would be useful to be able to use an analytical method for its estimation from parameters that are easier to obtain, such as the oxygen diffusion coefficient, which can be determined experimentally with less difficulty and could even be estimated analytically. This article describes a study carried out to establish the relationship between oxygen and radon diffusion coefficients in concrete with Ordinary Portland Cement, based on tests for various types of concrete.
7 February 2018 in International Journal of Ventilation
As a result of recent research at the Eduardo Torroja Institute for construction sciences, a new wording for the indoor air quality (IAQ) regulations for dwellings included in the Spanish Building Code has come into force with the main goal of adapting required ventilation rates to real needs to consequently achieve a reduction of energy demand with no negative impact on indoor air quality or on condensation risk. This paper summarises the research that was carried out to assess the variation in the surface condensation risk due to the reduction of the ventilation rates. A method to assess the influence of variations in ventilation on surface condensation risk was adapted. Results show how it should be possible to achieve target CO2 concentration values in addition to not significantly increase the risk of surface condensation.