Li Zhang

Dr. Li Zhang


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2018 in Cancer Imaging
Verified
Journal Article
Open access
PDF file
MLMeng Li
Meng Li
NWNing Wu
Ning Wu
LZLi Zhang
Li Zhang
WSWei Sun
Wei Sun
YLYing Liu
Ying Liu
DLDongmei Lin
Dongmei Lin
Preoperative tumor invasiveness in clinical stage T1N0M0 lung adenocarcinoma is critical for optimal surgical procedure. The aim of the present study was to evaluate the relationship between the ground-glass opacity component (GGOc) / solid component (Sc) proportion measured using three-dimensional (3D) computer-quantified computer tomography (CT) number analysis to explore radiographic features for invasiveness prediction in cT1N0M0 lung adenocarcinomas. A total of 375 surgically resected cT1N0M0 lung adenocarcinoma patients were included. The relativity between the GGOc/Sc proportion and lepidic growth pattern percentage was assessed using Spearman’s rank analysis. Multiple logistic regression analysis was used to determine independent factors from radiographic features for tumor invasiveness. Prediction probability for tumor invasiveness was analysed using a receiver operating characteristic curve (ROC). We found that the GGOc proportion was positively correlated with lepidic growth pattern percentage (r = 0.67, P < 0.01), while the Sc proportion was negatively correlated with it (r = − 0.74, P < 0.01). Multivariate analysis showed that tumor size and Sc proportion were identified as independent predictors for tumor invasiveness. The area under the ROC curve (AUC) of Sc proportion was 0.875, which was higher than that of tumor size (0.750) (P < 0.001), and had no significant difference with that of combination of these two factors (0.884) (P = 0.28). The GGOc/Sc proportion measured using 3D computer-quantified CT number analysis reflects the lepidic growth pattern percentage in tumors, and the Sc proportion may be an important factor for the prediction of tumor invasiveness in cT1N0M0 lung adenocarcinoma.

22 August 2016 in Cancer Imaging
Verified
Journal Article
Open access
PDF file
LZLi Zhang
Li Zhang
XZXinming Zhao
Xinming Zhao
HOHan Ouyang
Han Ouyang
SWShuang Wang
Shuang Wang
CZChunwu Zhou
Chunwu Zhou
The purpose of this study was to investigate the diagnostic value of 3.0-T 1H magnetic resonance spectroscopy (1H MRS) in primary malignant hepatic tumors and to compare the effects of 1H MRS on the diagnostic accuracy of liver-occupying lesions between junior and experienced radiologists. This study included 50 healthy volunteers and 40 consecutive patients (50 lesions). Informed consent was obtained from each subject. Images were obtained on clinical whole-body 3.0-T MR system. Point -Resolved Spectroscopy was used to obtain the spectroscopy image. All conventional images were reviewed blindly by junior radiologist and experienced radiologist, respectively. The choline-containing compounds peak area (CCC-A) was measured with SAGE software, and the choline-containing compound ratio (∆CCC) was calculated. The efficacy of CCC-A and ∆CCC in the diagnosis of primary malignant hepatic tumors was determined by plotting receiver operating characteristic (ROC) curves. We also compared the effects of MRS on the diagnostic accuracy of liver-occupying lesions with junior and experienced radiologist. A significant increase in mean CCC-A was observed in malignant tumors compared with benign tumors. The ROC curve showed ∆CCC had a high discriminatory ability in diagnosing primary malignant hepatic tumors with a sensitivity and specificity of 94.3 and 93.3 %, respectively. The ∆CCC area under the curve (AUC) was 0.97 that was larger than that of both junior and experienced radiologist, while the significantly statistical difference was only obtained between ∆CCC and junior radiologist (P = 0.01). 1H MRS with ∆CCC demonstrates good efficacy in diagnosing primary malignant hepatic tumors. The technique improves the accuracy of diagnosing liver-occupying lesions, particularly for junior radiologists.

6 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
LZLi Zhang
Li Zhang
LLLv Lv
Lv Lv
LLLin Li
Lin Li
YWYan-Mei Wang
Yan-Mei Wang
SZShuang Zhao
Shuang Zhao
NWNing Wu
Ning Wu
Objectives: To investigate the predictive ability of radiomics signature to predict the prognosis of early-stage primary lung adenocarcinoma (≤3 cm) with no lymph node metastasis (pathological stage I). Materials and Methods: This study included consecutive patients with lung adenocarcinoma (≤3 cm) with no lymph node metastasis (pathological stage I) and divided them into two groups: good prognosis group and poor prognosis group. The association between the radiomics signature and prognosis was explored. An integrative radiomics model was constructed to demonstrate the value of the radiomics signature for individualized prognostic prediction. Results: Six radiomics features were significantly different between the two prognosis groups and were used to construct a radiomics model. On the training and test sets, the area under the receiver operating characteristic curve value of the radiomics model in discriminating between the two groups were 0.946 and 0.888, respectively, and those of the pathological model were 0.761 and 0.798, respectively. A radiomics nomogram combining sex, tumor size and rad-score was built. Conclusion: The radiomics signature has potential utility in estimating the prognosis of patients with pathological stage I lung adenocarcinoma (≤3 cm), potentially enabling a step forward in precision medicine.

1 February 2021 in Annals of Translational Medicine
Verified
Journal Article
Open access
PDF file
SYShouxin Yang
Shouxin Yang
NWNing Wu
Ning Wu
LZLi Zhang
Li Zhang
MLMeng Li
Meng Li
Background: To investigate the influence of slice thickness on radiomic feature (RF) values in solid pulmonary nodules and evaluate the effect of a linear interpolation method in correcting the influence. Methods: Thirty pulmonary nodules from 28 patients were selected prospectively with a thick-slice of 5 mm and a thin-slice of 1.25 mm on CT. A resampling method was used to normalize the voxel size of thick and thin slices CT images to 1×1×1 mm3 by linear interpolation. Lung nodules were segmented manually. A total of 396 radiomic features (RFs) were extracted from thick-slice and thin-slice images, together with the images resampled from thick (thick-r) and thin (thin-r) slices. The differences between the RF values were evaluated using a paired t-test. A comparison between groups was made using the Chi-squared test. Results: Among the 396 RFs, 305 RFs showed an intraclass correlation coefficient ≥0.75 after test-retest analysis (including 22 histogram features, 20 geometry features, and 263 texture features). In the non-resampled data, 239 RF values (78.4%, 239/305) showed significant differences between thick and thin slice CT images. Resampling of thick images revealed that 202 RF values (66.2%, 202/305) showed significant differences between thick-r and thin slice CT images, showing a significant decrease in the number of different RF values when compared to non-resampled data (P<0.01). For the RF subgroups, only texture features showed a significant reduction in the number of different RF values after resampling (P<0.01). When both thick and thin slice images were resampled, the number of significantly different RF values between thick-r and thin-r images was increased to 247 (81.0%, 247/305), showing no significant difference when compared to non-resampled data (P=0.421). Conclusions: Slice thickness demonstrated a considerable influence on RF values in solid pulmonary nodules, producing false results when CT images with different slice thicknesses were used. Linear interpolation of the resampling method was limited because of the relatively small correction effect.