Low-cost monitors for measuring airborne contaminants have gained popularity due to their affordability, portability, and ease of use. However, they often exhibit significant biases compared to high-cost reference instruments. For optimal accuracy, these monitors require calibration and validation in their specific environment using expensive reference instruments, which are often scarce and costly. This study proposes machine-learning calibration methods that utilize a single high-cost instrument as an active reference to improve the accuracy of large networks of low-cost monitors. Three machine learning models-linear regression, random forest, and Gradient Boosting Regression (GBR)-were employed. The proposed approach was tested in a controlled chamber under two conditions: environmental simulations with salt- and dust-based aerosols and occupational settings using three electronic cigarette (ECIG) brands. The study involved thirty low-cost GeoAir2 monitors, divided into ten groups of three. Initially, all groups were collocated with a high-cost monitor using Aerosol A to develop prediction and regression models. These models, along with intrinsic error measurements from one group, were then applied to improve data accuracy for the remaining groups using Aerosol B. The results demonstrated substantial improvements in accuracy, with r2 values ranging from 0.91 to 1.00 and RMSE reductions of up to 88 %, depending on the model and aerosol type. GBR consistently provided the highest accuracy and performance, particularly for complex, nonlinear patterns, while linear regression offered a faster, computationally efficient alternative suitable for less demanding scenarios. Random forest models performed moderately well, balancing accuracy and complexity. These methods provide a scalable and cost-effective solution for deploying networked low-cost sensors. Further research is needed to validate these findings in outdoor environments with meteorological and spatial influences, and indoor occupational settings where humidity effects may play a role.
Electronic cigarette (ECIG) liquids are marketed with labeled nicotine concentrations and propylene glycol (PG) to vegetable glycerin (VG) ratios, yet quality control inconsistencies may alter vaping emissions. We quantified discrepancies between labeled and measured chemical content and evaluated how these differences affect emissions of particulate matter with an aerodynamic diameter of 2.5 µm or smaller (PM2.5). Flavor-free liquids (n = 20) spanning nicotine labels of 0, 9, 18, and 48 mg/mL and PG content from 0% to 80% were purchased. Nuclear magnetic resonance spectroscopy measured nicotine, PG, and VG. Aerosols were generated using a standardized device in a controlled exposure chamber. PM2.5 was measured using a pDR-1500 and SMPS/APS, with gravimetric correction factors calculated. Labeling inaccuracies were widespread: “nicotine-free” liquids contained 0.1 to 0.4 mg/mL nicotine, and labeled nicotine deviated by up to ±30%. PG/VG ratios were frequently incorrect; 70% of samples contained higher VG than labeled, including “100% VG” products with about 10% PG. Higher VG consistently increased PM2.5 mass, while nicotine had a minimal effect. The pDR overestimated mass, whereas SMPS/APS underestimated due to volatilization losses. Overall, inaccurate ECIG liquid labeling can alter measured PM2.5 emissions under controlled conditions.