Jung-Hao Wang

Dr. Jung-Hao Wang

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2008 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
THTsung-Min Hsieh
Tsung-Min Hsieh
CLChing-Hsing Luo
Ching-Hsing Luo
JWJung-Hao Wang
Jung-Hao Wang
JLJr-Lung Lin
Jr-Lung Lin
KLKang-Yi Lien
Kang-Yi Lien
GLGwo-Bin Lee
Gwo-Bin Lee

21 December 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
GBGia Thinh Bui
Gia Thinh Bui
JWJung-Hao Wang
Jung-Hao Wang
Jr-Lung LinJr-Lung Lin
Jr-Lung Lin
In this study, we successfully designed and tested a new micropump that utilizes an active check valve and bottom-protruding structure to achieve sample transportation. We performed theoretical analyses and numerical simulations to determine the optimal location of the active check valve. We also experimentally analyzed variations in the generated flow rate with respect to the pneumatic frequencies, actuated air pressures, and locations of the active check valve. The experimental results indicate the optimum air pressure, driving frequency, and location of the active check valve to be 68.9 kPa, 26.0 Hz, and 2.0 mm, respectively. We obtained a maximum pumping rate of 488 μL/min and a maximum pumping efficiency of 35.4%. The proposed micropump could perform a crucial function in the transportation of microfluids and could be incorporated into micro total analysis systems.

17 July 2013 in Micromachines
Verified
Journal Article
Open access
PDF file
JWJung-Hao Wang
Jung-Hao Wang
GLGwo-Bin Lee
Gwo-Bin Lee
A mono-dispersed emulsion is of great significance in many chemical, biomedical and industrial applications. The current study reports a new microfluidic chip capable of forming tunable micro-droplets in liquids for emulsification applications. It can precisely generate size-tunable, uniform droplets using flow-focusing channels and a normally-closed valve, which is opened by a pneumatic suction force. Experimental data showed that micro-droplets with a diameter ranging from several to tens of micrometers could be precisely generated with a high uniformity. The droplet size is experimentally found to be dependent on the velocity of the dispersed-phase liquid, which is controlled by the deflection of the suction membrane. Emulsions with droplet sizes ranging from 5.5 to 55 μm are successfully observed. The variation in droplet sizes is from 3.8% to 2.5%. The micro-droplets have a uniform size and droplets smaller than those reported in previous studies are possible with this approach. This new microfluidic device can be promising for emulsification and other related applications.

30 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HYHsing-Cheng Yu
Hsing-Cheng Yu
MTMing-Yang Tsai
Ming-Yang Tsai
YTYuan-Chih Tsai
Yuan-Chih Tsai
JYJhih-Jyun You
Jhih-Jyun You
CCChun-Lin Cheng
Chun-Lin Cheng
SLSzu-Ju Li
Szu-Ju Li
Recently, environmental pollution resulting from industrial waste has been emerging in an endless stream. The industrial waste contains chemical materials, heavy metal ions, and other toxic materials. Once the industrial waste is discharged without standards, it might lead to water or environmental pollution. Hence, it has become more important to provide evidence-based water quality monitoring. The use of a multifunctional miniaturized water quality monitoring system (WQMS), that contains continuous monitoring, water quality monitoring, and wireless communication applications, simultaneously, is infrequent. Thus, electrodes integrated with polydimethylsiloxane flow channels were presented in this study to be a compound sensor, and the sensor can be adopted concurrently to measure temperature, pH, electrical conductivity, and copper ion concentration, whose sensitivities are determined as 0.0193 °C/mV, −0.0642 pH/mV, 1.1008 mS/V·cm (from 0 mS/cm to 2 mS/cm) and 1.1975 mS/V·cm (from 2 mS/cm to 5.07 mS/cm), and 0.0111 ppm/mV, respectively. A LoRa shield connected into the system could provide support as a node of long range wide area network (LoRaWAN) for wireless communication application. As mentioned above, the sensors, LoRa, and circuit have been integrated in this study to a continuous monitoring system, WQMS. The advantages of the multifunctional miniaturized WQMS are low cost, small size, easy maintenance, continuous sampling and long-term monitoring for many days. Every tested period is 180 min, and the measured rate is 5 times per 20 min. The feedback signals of the miniaturized WQMS and measured values of the instrument were obtained to compare the difference. In the measured results at three different place-to-place locations the errors of electrical conductivity are 0.051 mS/cm, 0.106 mS/cm, and 0.092 mS/cm, respectively. The errors of pH are 0.68, 0.87, and 0.56, respectively. The errors of temperature are 0.311 °C, 0.252 °C, and 0.304 °C, respectively. The errors of copper ion concentration are 0.051 ppm, 0.058 ppm, 0.050 ppm, respectively.