Spyridon Angelopoulos

Dr. Spyridon Angelopoulos

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2023 in Electronics
Verified
Journal Article
Open access
PDF file
TAThelma Androutsou
Thelma Androutsou
SASpyridon Angelopoulos
Spyridon Angelopoulos
Evangelos HristoforouEvangelos Hristoforou
Evangelos Hristoforou
George K. MatsopoulosGeorge K. Matsopoulos
George K. Matsopoulos
Dimitris Dionissios KoutsourisDimitris Dionissios Koutsouris
Dimitris Dionissios Koutsouris
Nowadays, changes in the conditions and nature of the workplace make it imperative to create unobtrusive systems for the automatic detection of occupational stress, which can be feasibly addressed through the adoption of Internet of Things (IoT) technologies and advances in data analysis. This paper presents the development of a multimodal automated stress detection system in an office environment that utilizes measurements derived from individuals’ interactions with the computer and its peripheral units. In our analysis, behavioral parameters of computer keyboard and mouse dynamics are combined with physiological parameters recorded by sensors embedded in a custom-made smart computer mouse device. To validate the system, we designed and implemented an experimental protocol simulating an office environment and included the most known work stressors. We applied known classifiers and different data labeling methods to the physiological and behavioral parameters extracted from the collected data, resulting in high-performance metrics. The feature-level fusion analysis of physiological and behavioral parameters successfully detected stress with an accuracy of 90.06% and F1 score of 0.90. The decision-level fusion analysis, combining the features extracted from both the computer mouse and keyboard, showed an average accuracy of 66% and an average F1 score of 0.56.

20 December 2023 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
PPPanagiotis Priftis
Panagiotis Priftis
SASpyridon Angelopoulos
Spyridon Angelopoulos
Aphrodite KtenaAphrodite Ktena
Aphrodite Ktena
Evangelos HristoforouEvangelos Hristoforou
Evangelos Hristoforou

22 December 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
TAThelma Androutsou
Thelma Androutsou
SASpyridon Angelopoulos
Spyridon Angelopoulos
Evangelos HristoforouEvangelos Hristoforou
Evangelos Hristoforou
George K. MatsopoulosGeorge K. Matsopoulos
George K. Matsopoulos
Dimitris Dionissios KoutsourisDimitris Dionissios Koutsouris
Dimitris Dionissios Koutsouris
Occupational stress is a major challenge in modern societies, related with many health and economic implications. Its automatic detection in an office environment can be a key factor toward effective management, especially in the post-COVID era of changing working norms. The aim of this study is the design, development and validation of a multisensor system embedded in a computer mouse for the detection of office work stress. An experiment is described where photoplethysmography (PPG) and galvanic skin response (GSR) signals of 32 subjects were obtained during the execution of stress-inducing tasks that sought to simulate the stressors present in a computer-based office environment. Kalman and moving average filters were used to process the signals and appropriately formulated algorithms were applied to extract the features of pulse rate and skin conductance. The results found that the stressful periods of the experiment significantly increased the participants’ reported stress levels while negatively affecting their cognitive performance. Statistical analysis showed that, in most cases, there was a highly significant statistical difference in the physiological parameters measured during the different periods of the experiment, without and with the presence of stressors. These results indicate that the proposed device can be part of an unobtrusive system for monitoring and detecting the stress levels of office workers.

5 October 2022 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
SASpyridon Angelopoulos
Spyridon Angelopoulos
PPPanagiotis Priftis
Panagiotis Priftis
AAAndreas Anastasopoulos
Andreas Anastasopoulos
Aphrodite KtenaAphrodite Ktena
Aphrodite Ktena
Evangelos HristoforouEvangelos Hristoforou
Evangelos Hristoforou
Fluxgate magnetometers are widely used, as they exhibit high sensitivity, while operating at room temperature. However, their cost, as well as the need for additional external units (e.g., power supply, data acquisition units, and so on), may act as negative factors. In this article, a new fluxgate magnetometer is presented based on a pulsed excitation signal, offering low power consumption and high sensitivity, while being low-cost and small. It can operate in open-loop or closed-loop mode, depending on the application and the strength of the externally imposed magnetic fields. The sensor’s racetrack topology, consisting of two excitation coils and one sensing coil, eliminates the effect of the sensor’s excitation field, in order to detect only the externally imposed magnetic field. Moreover, an additional coil is used to compensate the external magnetic field during the closed-loop operating mode. The device is completed with the required electronics and a microcontroller to generate the sensor’s excitation signal, receive its output, and compensate the magnetic background through proportional–integral–derivative (PID) control. Measurements can be transmitted in a wired or wireless manner to the desired device (e.g., personal computer, smartphone, and so on). The printed circuit board (PCB) of the sensor was designed and manufactured, including the electronics, as well as a rechargeable lithium battery to demonstrate the portability of the sensor. The final device was mounted in a 3-D printed enclosure, enabling its use under a variety of conditions. Initial measurements show that the sensor can act as a magnetic anomaly detector, exhibiting high sensitivity. As a result, it can be used for geomagnetic, biomedical, non-destructive testing, and other applications.

1 December 2020 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
SASpyridon Angelopoulos
Spyridon Angelopoulos
DMD. Misiaris
D. Misiaris
GBG. Banis
G. Banis
KLK. Liang
K. Liang
PTP. Tsarabaris
P. Tsarabaris
EHE. Hristoforou
E. Hristoforou

20 February 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
GBGeorgios Banis
Georgios Banis
KTKonstantinos Tyrovolas
Konstantinos Tyrovolas
SASpyridon Angelopoulos
Spyridon Angelopoulos
Angelo FerraroAngelo Ferraro
Angelo Ferraro
Evangelos HristoforouEvangelos Hristoforou
Evangelos Hristoforou
Treatment of certain diseases requires the administration of drugs at specific areas of tissues and/or organs to increase therapy effectiveness and avoid side effects that may harm the rest of the body. Drug targeting is a research field that uses various techniques to administrate therapies at specific areas of the body, including magnetic systems able to drive nano “vehicles”, as well as magnetically labeled molecules, in human body fluids and tissues. Most available actuation systems can only attract magnetic elements in a relatively small workspace, limiting drug target applications to superficial tissues, and leaving no alternative cases where deep targeting is necessary. In this paper, we propose an electromagnetic actuation system able to push and deflect magnetic particles at distance of ~10 cm, enabling the manipulation of magnetic nano- and microparticles, as well as administration of drugs in tissues, which are not eligible for localized drug targeting with state-of-the-art systems. Laboratory experiments and modeling were conducted to prove the effectiveness of the proposed system. By further implementing our device, areas of the human body that previously were impossible to treat with magnetically labeled materials such as drugs, cells, and small molecules can now be accessible using the described system.