The respiratory microbiome is altered in COPD patients but its relationship with core components of the disease, such as the severity of airflow limitation, the frequency of exacerbations or the circulating levels of eosinophils, is unclear. Cross-sectional study comprising 72 clinically stable COPD patients (mean age 68 [SD 7.9] years; FEV1 48.7 [SD 20.1]% of reference) who provided spontaneous sputum samples for 16S rRNA gene amplification and sequencing. The microbiome composition was analysed with QIIME. We observed that: (1) more severe airflow limitation was associated with reduced relative abundance (RA) of Treponema and an increase in Pseudomonas; (2) patients with ≥2 exacerbations the previous year showed a significantly different bacterial community with respect to non-exacerbators (p = 0.014), with changes in 13 genera, including an increase of Pseudomonas, and finally, (3) peripheral eosinophils levels ≥2% were associated with more diverse microbiome [Chao1 224.51 (74.88) vs 277.39 (78.92) p = 0.006; Shannon 3.94 (1.05) vs 4.54 (1.06) p = 0.020], and a significant increase in the RAs of 20 genera. The respiratory microbiome in clinically stable COPD patients varies significantly according to the severity of airflow limitation, previous history of exacerbations and circulating eosinophils levels.
The choice of a ventilator model for a single patient is usually based on parameters such as size (portability), presence or absence of battery and ventilatory modes. However, there are many details within each ventilator model about triggering, pressurisation or autotitration algorithms that may go unnoticed, but may be important or may justify some drawbacks that may occur during their use in individual patients. This review is intended to emphasize these differences. Guidance is also provided on the operation of autotitration algorithms, in which the ventilator is able to take decisions based on a measured or estimated parameter. It is important to know how they work and their potential sources of error. Current evidence on their use is also provided.
1 January 2022 in International Journal of Chronic Obstructive Pulmonary Disease
Purpose: The European Task Force for chronic non-invasive ventilation in stable COPD recommends the use of high pressure-support (PS) level to maximize the decrease in PaCO2. It is possible that the ventilator model can influence the need for higher or lower pressure levels. Research Question: To determine the differences between ventilators in a bench model with an increased inspiratory demand; and to compare the degree of muscular unloading measured by parasternal electromyogram (EMGpara) provided by the different ventilators in real patients with stable COPD. Patients and Methods: Bench: four levels of increasing progressive effort were programmed. The response of nine ventilators to four levels of PS and EPAP of 5 cm H2O was studied. The pressure-time product was determined at 300 and 500 msec (PTP 300/500). Clinical Study: The ventilators were divided into two groups, based on the result of the bench test. Severe COPD patients with non-invasive ventilation (NIV) were studied, randomly comparing the performance of one ventilator from each group. Muscle unloading was measured by the decrease in EMGpara from its baseline value. Results: There were significant differences in PTP 300 and PTP 500 in the bench study. Based on these results, home ventilators were classified into two groups; group 1 included four models with higher PTP 300. Ten COPD patients were recruited for the clinical study. Group 1 ventilators showed greater muscle unloading at the same PS than group 2. Conclusion: The scale of pressure support in NIV for high intensity ventilation may be influenced by the ventilator model. Clinical Trials.gov: NCT03373175.
Humidification and non-invasive ventilation are frequently used together, despite the lack of precise recommendations regarding this practice. We aimed to analyse the impact of active external and built-in humidifiers on the performance of home ventilators, focusing on their pressurization efficacy and their behaviour under different inspiratory efforts. We designed a bench study of a lung simulator programmed to emulate mechanical conditions similar to those experienced by real respiratory patients and to simulate three different levels of inspiratory effort: five different commonly used home NIV devices and active humidifiers attached to the latter (internal or "built-in") or to the circuit (external). To test ventilator pressurization under different humidification and effort settings, pressure-time products in the first 300ms and 500ms of the respiratory cycle were calculated in the 45 situations simulated. Inferential statistical analysis was performed. A significant reduction of PTP 300 and PTP 500 was observed with the external humidifier in three of the devices. The same pattern was noted for another device with an internal humidifier, and only one device showed no significant changes. This impact on pressurization was commonly higher under high inspiratory effort. These results indicate the need to monitor pressure changes in the use of external humidification devices in some home NIV ventilators.