In 2015, U.K. newborn screening (NBS) laboratory guidelines were introduced to standardize dried blood spot (DBS) specimen quality acceptance and specify a minimum acceptable DBS diameter of ≥7 mm. The UK ‘acceptable’ avoidable repeat rate (AVRR) is ≤2%. To assess inter-laboratory variability in specimen acceptance/rejection, two sets of colored scanned images (n = 40/set) of both good and poor-quality DBS specimens were distributed to all 16 U.K. NBS laboratories for evaluation as part of an external quality assurance (EQA) assessment. The mean (range) number of specimens rejected in the first EQA distribution was 7 (1–16) and in the second EQA distribution was 7 (0–16), demonstrating that adherence to the 2015 guidelines was highly variable. A new minimum standard for DBS size of ≥8 mm (to enable a minimum of six sub-punches from two DBS) was discussed. NBS laboratories undertook a prospective audit and demonstrated that using ≥8 mm as the minimum acceptable DBS diameter would increase the AVRR from 2.1% (range 0.55% to 5.5%) to 7.8% (range 0.55% to 22.7%). A significant inverse association between the number of specimens rejected in the DBS EQA distributions and the predicted AVVR (using ≥8 mm minimum standard) was observed (r = −0.734, p = 0.003). Before implementing more stringent standards, the impact of a standard operating procedure (SOP) designed to enable a standardized approach of visual assessment and using the existing ≥7 mm diameter (to enable a minimum of four sub-punches from two DBS) as the minimum standard was assessed in a retrospective audit. Implementation of the SOP and using the ≥7 mm DBS diameter would increase the AVRR from 2.3% (range 0.63% to 5.3%) to 6.5% (range 4.3% to 20.9%). The results demonstrate that there is inconsistency in applying the acceptance/rejection criteria, and that a low AVVR is not an indication of good-quality specimens being received into laboratories. Further work is underway to introduce and maintain standards without increasing the AVRR to unacceptable levels.
16 October 2009 in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Background: Current gold standard markers for myocardial damage are troponins I and T, which are both sensitive and specific for the detection of myocardial infarction, but require up to 6 h to become reliably elevated in serum. Investigation into markers with potential to identify patients with early ischaemic changes is therefore intense. Choline is reported to be prognostic in patients presenting with acute coronary syndromes via its release from ischaemic cell membranes. Methods: Liquid chromatography tandem mass spectrometry was used to develop a method to quantitate choline in plasma and blood. The method involves addition of a deuterated internal standard to an aliquot of plasma or blood followed by organic solvent addition, which precipitates the proteins in the sample. Preparation was carried out directly into a 96-deep-well plate. Chromatography of choline used a strong cation exchange column and separation used a Waters Atlantis dC18 analytical column positioned directly before the mass spectrometer source, allowing on-line preanalytical clean up of the sample. Results: The lower limit of quantitation was 0.38 μmol/L, linearity was observed up to 754 μmol/L, with a working concentration range of 0.38–224 μmol/L, inter- and intra-assay coefficients of variation were <6% and <4%, respectively. Samples were stable throughout five freeze–thaw cycles and recovery was between 94% and 114%. Conclusions: The assay was successfully validated in accordance with FDA guidelines and is suitable for quantitation of choline in research and clinical settings.
In 2015, the newborn screening (NBS) programmes in England and Wales were expanded to include four additional disorders: Classical Homocystinuria, Isovaleric Acidemia, Glutaric Aciduria Type 1 and Maple Syrup Urine Disease, bringing the total number of analytes quantified to eight: phenylalanine, tyrosine, leucine, methionine, isovalerylcarnitine, glutarylcarnitine, octanoylcarnitine and decanoylcarnitine. Post-implementation, population data monitoring showed that inter-laboratory variation was greater than expected, with 90th centiles varying from 17% to 59%. We evaluated the effect of stable isotope internal standard (IS) used for quantitation on inter-laboratory variation. Four laboratories analysed routine screening samples (n > 101,820) using a common IS. Inter-laboratory variation was determined for the eight analytes and compared with results obtained using an in-house common IS (n > 102,194). A linear mixed-effects model was fitted to the data. Using a common IS mix reduced the inter-laboratory variation significantly (p < 0.05) for five analytes. For three analytes, the lack of significance was explained by use of individual laboratory “calibration factors”. For screening programmes where laboratories adhere to single analyte cut-off values (COVs), it is important that inter-laboratory variation is minimised, primarily to prevent false positive results. Whilst the use of a common IS helps achieve this, it is evident that instrument set-up also contributes to inter-laboratory variation.
Increasing ethnic diversity raises potential inequalities within screening programmes. In the UK, newborns are screened for CF by initially measuring IRT. Dried blood spot IRT levels above a set cut-off require follow-up testing to establish a screening result. Variation exists in IRT levels between different ethnicities and therefore impacts the number of potentially false positive results obtained from ethnic groups. Over a 4-year period, IRT data was collected, and the 99.5th centile was calculated for different ethnic groups. Significant differences were noticed between ethnic groups, and the CF outcome data over a 10-year period were then analysed to establish the effect this had on positive predictive values. The largest difference in IRT 99.5th centile values was seen between the White British and Black African groups. Positive predictive values for Black African and Indian ethnic groups were much lower than the other groups. Rather than try to incorporate ethnicity into the UK CF screening algorithm, we suggest making CF clinicians aware of the differences between different ethnic groups to inform counselling families who receive screen-positive results.