Suyane Luna-Cruz

Prof. Dr. Suyane Luna-Cruz

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2021 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
FVFrancisca Lívia Parente Viana
Francisca Lívia Parente Viana
MSMarcelo Bonifácio da Silva Sampieri
Marcelo Bonifácio da Silva Sampieri
PVPriscilla Parente Viana
Priscilla Parente Viana
SCSuyane Maria Luna Cruz
Suyane Maria Luna Cruz
RRODRIGO VIVAN
RODRIGO VIVAN
BVBruno Carvalho Vasconcelos
Bruno Carvalho Vasconcelos
As medicações intracanais com atividade antimicrobiana são importantes como coadjuvantes na desinfecção do sistema de canais radiculares. Diante disso, esse estudo avaliou, in vitro, o pH e a atividade antimicrobiana de um novo medicamento intracanal biocerâmico (Bio-C Temp) em comparação com medicações a base de hidróxido de cálcio (HC). A determinação do pH foi realizada por meio de um pHmetro nos períodos de 30 minutos, 3, 24, 72 e 168 horas. As medicações Ultracal®XS, Hidróxido de cálcio com soro (HC/Soro), Hidróxido de cálcio com propilenoglicol (HC/PG) e Bio-C Temp (biocerâmico) foram testadas contra biofilmes de duas cepas de Enterococcus faecalis (ATCCs 29212 e 4083) usando os testes de contato direto (TCD) e restrito por membrana (TRM). A sobrevivência bacteriana foi determinada pela contagem das unidades formadoras de colônias (UFCs) e os dados foram comparados estatisticamente (P < 0,05). A pasta Bio-C Temp apresentou o menor valor de pH nos tempos avaliados. Os grupos HC/Soro e HC/PG apresentaram maior ação frente ao controle no TCD (P < 0,05) contra as duas cepas testadas. Ainda, o HC/PG mostrou maior atividade antibacteriana que o Bio-C Temp (P < 0,05). Todos os grupos apresentaram diferença ante o grupo controle no TRM contra a cepa 29212, e somente o HC/PG mostrou diferença significativa frente ao controle contra biofilmes da cepa 4083. O Bio-C Temp mostrou ação antibacteriana similar ao Ultracal®XS, no entanto apresentou menor ação em relação ao HC/PG. A pasta de hidróxido de cálcio associada com propilenoglicol mostrou vantagens em relação às demais testadas.

1 January 2024 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
SLSuyane Maria Luna-Cruz
Suyane Maria Luna-Cruz
BABernardo Almeida Aguiar
Bernardo Almeida Aguiar
PFPierre Fechine
Pierre Fechine
MDMarco Antonio Hungaro Duarte
Marco Antonio Hungaro Duarte
BVBruno Carvalho Vasconcelos
Bruno Carvalho Vasconcelos
JMJuliano Sartori Mendonça
Juliano Sartori Mendonça
This study evaluated some physicochemical properties of an experimental tricalcium silicate-based cement (ETSC) indicated for use as pulp capping or endodontic repair material; Biodentine (BD) and White MTA-Angelus (MTA) cements served as comparators. Setting time, radiopacity, sorption, and solubility were determined according to ISO 6876/2012 and compressive strength according to ISO 9917-1/2019. pH and calcium ion release capacity were also assessed. Data were analyzed using ANOVA and Tukey tests or Kruskal-Wallis and Dunn tests with α = 0.05. BD (15’) and ETSC (17.3’) exhibited the shortest initial setting times, with BD (29’) having the shortest final setting time; MTA showed longer times in both analyses (p < 0.05). ETSC and MTA showed the highest radiopacity (6.1 mm Al and 5.7 mm Al), while BD showed the lowest (3.0 mm Al) (p < 0.05). BD exhibited the highest compressive strength (88.8 MPa), significantly higher than the others (p < 0.05). BD presented the lowest values for sorption, 0.12% (24 h) and 0.48% (28 d), which differed significantly from MTA (p < 0.05). The lowest values for solubility were shown for ETSC, 0.26% (24 h), and BD, 0.52% (28 d), which differed significantly from MTA (p<0.05). ETSC showed the highest pH throughout all periods; significant differences were observed for MTA (3 h) and BD (24 h) (p<0.05). In the Ca2+ analysis, BD provided the highest values in all periods; differences were only significant compared to MTA (3h/24h) (p <0 .05). Considering the study conditions, it can be concluded that ETSC exhibited characteristics similar or better properties than the commercial cements tested, except for compressive strength.

20 November 2025 in Journal of Advances in Medicine and Medical Research
Verified
Journal Article
Closed access
ASAndresa Pereira Santiago
Andresa Pereira Santiago
TVThais da Ponte Vasconcelos
Thais da Ponte Vasconcelos
YAYana Cavalcante De Araújo
Yana Cavalcante De Araújo
MDMirlyn de Souza Dias
Mirlyn de Souza Dias
JFJoana Lia Freitas Furtado
Joana Lia Freitas Furtado
BVBruno Carvalho de Vasconcelos
Bruno Carvalho de Vasconcelos
Aims: To describe the endodontic treatment of a tooth with extensive calcification in the pulp chamber, using the guided endodontic technique (Endoguide). Case Report: A 36-year-old female patient, with normal systemic function, presented to the Dental Clinic of UFC - Sobral Campus for evaluation. After anamnesis, clinical and radiographic examinations, endodontic treatment was deemed necessary for tooth 13, which presented with necrosis and periapical rarefaction. The same radiographic examination identified that the tooth presented with pulpal calcification extending to the middle third of the root. As a complementary examination, a cone-beam computed tomography scan was requested, which guided the fabrication of the guide. With this guide and the aid of a specific drill operated at low speed, access to the root canal was achieved without major difficulties. Odontometry and instrumentation of the canal were then performed with instruments from the Reciproc system (R25 and R40); subsequently, calcium hydroxide paste was applied and remained in place for 21 days. The root canal obturation was performed with Hydro Sealer endodontic cement and gutta-percha using the modified Tagger Hybrid technique. Conclusion: The Endoguide proved to be an efficient and easy-to-use tool, acting as a facilitator during the endodontic treatment of the reported case, minimizing the risk of accidents and increasing the predictability of the procedure.

6 December 2024 in Australian Endodontic Journal
Verified
Journal Article
Closed access
LFLuciana Maria Arcanjo Frota
Luciana Maria Arcanjo Frota
BABernardo Almeida Aguiar
Bernardo Almeida Aguiar
SLSuyane Maria Luna‐Cruz
Suyane Maria Luna‐Cruz
ALAna Limoeiro
Ana Limoeiro
MAMurilo Priori Alcalde
Murilo Priori Alcalde
BVBruno Carvalho Vasconcelos
Bruno Carvalho Vasconcelos

1 November 2025 in Archives of Current Research International
Verified
Journal Article
Closed access
JFJoana Lia Freitas Furtado
Joana Lia Freitas Furtado
YAYana Cavalcante De Araújo
Yana Cavalcante De Araújo
MMMaria Franciele Soares Matos
Maria Franciele Soares Matos
RLRebecca Beatriz Alves Lima
Rebecca Beatriz Alves Lima
SLSuyane Maria Luna-Cruz
Suyane Maria Luna-Cruz
BVBruno Carvalho Vasconcelos
Bruno Carvalho Vasconcelos
Aims: To evaluate the color change (ΔE) induced by the endodontic cements: Endofill (EF), Sealer 26 (S26) and MTA Fillapex (MTAF); as well as to investigate the impact of ultrasonic agitation (UA) on the degree of discoloration produced. Methodology: Sixty bovine incisor blocks were prepared, in which circular cavities were created on the palatal surfaces, preserving a 2.0 mm thick dentin remnant. The specimens were distributed into six groups according to the endodontic cement and treatment employed. When present, ultrasonic agitation (UA) was performed using a smooth insert coupled to a piezoelectric device. Color parameter measurements were obtained using a Vita Easyshade spectrophotometer immediately after material insertion and restoration (T0), and subsequently at 7 (T1), 30 (T2), 60 (T3), 90 (T4), and 180 days (T5). Throughout the experimental period, the specimens remained immersed in 2 mL of saline solution and stored in an incubator at 37 °C. The statistical analysis of the data was conducted using the Kruskal-Wallis and Dunn tests, adopting a significance level of 5%. Results: It was found that, at 7 and 30 days, only the Endofill (EF) group without ultrasonic agitation (UA) exhibited ΔE values ​​greater than 3.7 (the limit considered clinically perceptible for color change). After 60 days, all cements evaluated showed ΔE above this threshold, indicating perceptible discoloration in all groups. Comparative analysis revealed statistically significant differences in discoloration among Endofill, Sealer 26 and MTA Fillapex, indicating that color alteration progressed consistently over time (P < 0.05). Conclusion: The results of this study showed that, although only Endofill (EF) cement exhibited a perceptible color change in the initial periods, by the end of the evaluation all materials tested showed some degree of darkening. Furthermore, the use of ultrasonic agitation (UA) did not have a significant impact on the observed color variations.

31 July 2023 in Arquivos de Ciências da Saúde da UNIPAR
Verified
Journal Article
Open access
PDF file
LCLiziane Vasconcelos Carneiro
Liziane Vasconcelos Carneiro
BABernardo Almeida Aguiar
Bernardo Almeida Aguiar
SLSuyane Luna-Cruz
Suyane Luna-Cruz
EJElilton Cavalcante Pinheiro Júnior
Elilton Cavalcante Pinheiro Júnior
NVNilton Vivacqua-Gomes
Nilton Vivacqua-Gomes
BVBruno Carvalho Vasconcelos
Bruno Carvalho Vasconcelos
Avaliou-se a influência da utilização da agitação ultrassônica na resistência de união à dentina, por meio de push-out, proporcionada pelos cimentos MTA-Angelus branco (MTA) e Biodentine (BD), empregados no selamento de perfurações de furca. Foram utilizados 48 primeiros ou segundos molares inferiores, com raízes não fusionadas, distantes cerca de 2 mm entre si na porção cervical das mesmas. Os dentes foram acessados e, em seguida, as raízes foram seccionadas transversalmente abaixo da junção cemento-esmalte. Os dentes foram montados em blocos de silicona de adição e perfurações de furca realizadas em seus assoalhos paralelamente ao longo eixo dos dentes e perpendiculares aos assoalhos dentais. A amostra foi dividida em quatro grupos (n = 12) em função do material reparador e da utilização ou não da agitação ultrassônica (AU). Quando empregada, a AU foi aplicada em 2 ciclos de 20 segundos por meio de inserto cônico liso acionado por ultrassom piezoelétrico. Concluídos os selamentos eles foram protegidos com cimento de ionômero de vidro e os dentes imersos em PBS. Decorridos 7 dias discos com 1 mm de altura foram retirados dos assoalhos dentais com auxílio de cortadora metalográfica e levados à máquina de ensaio universal. Os resultados expressos em MPa foram submetidos aos testes ANOVA dois fatores e de Bonferroni. Os maiores valores de resistência obtidos foram no grupo Biodentine com ultrassom (29,41 MPa), seguidos em ordem decrescente pelos grupos Biodentine sem ultrassom; MTA com ultrassom e MTA sem ultrassom (3,72 MPa). Nas condições do estudo concluiu-se que o BD apresentou maior resistência de união à dentina radicular; ainda, que a agitação ultrassônica influenciou positivamente na resistência de união do material à dentina.