Transcatheter tricuspid valve replacement (TTVR) has been recently approved for the treatment of patients with severe tricuspid regurgitation (TR). Real-world evidence regarding the commercial use of TTVR is lacking. The aim of this study was to investigate the real-world safety and efficacy of the EVOQUE TTVR system in patients with severe TR treated at 12 experienced heart valve centers in 5 European countries. Consecutive patients treated with the EVOQUE system since approval in Europe (October 2023 to February 2025) were included in this retrospective analysis. Clinical outcomes were assessed at 30-day follow-up. The study included 176 patients (mean age 77.8 years, 72.0% women, median TRI-SCORE 5 points [IQR: 2 points]). At a median follow-up time of 30 days (IQR: 2 days), severe or greater TR was reduced to mild or none in 126 of 128 patients (98.4%; P < 0.001). NYHA functional class improved from 20.2% (28 of 138) class I or II at baseline to 79.7% (110 of 138; P) at 1 month (P < 0.001), with signs of improved hepatorenal function (estimated glomerular filtration rate 47.0 ± 19.9 mL/min/1.73 m2 vs 53.7 ± 23.3 mL/min/1.73 m2 [P < 0.001]; bilirubin 14.2 ± 8.8 μmol/L vs 11.0 ± 9.8 μmol/L [P < 0.001]). Massive or torrential TR at baseline was more common among patients who improved compared with those with stable or worsening NYHA functional class (75 of 98 [76.5%] vs 20 of 40 [50.0%]; P = 0.004). Permanent pacemaker implantation was required in 21 of 111 pacemaker-naive patients (18.9%), in particular those with conduction disturbances at baseline (OR: 4.53; 95% CI: 1.73-11.82; P = 0.002). Moderate or severe right ventricular dysfunction was an independent predictor of clinical failure at 1-month follow-up (OR: 3.60; 95% CI: 1.39-9.32, P = 0.008). TR elimination following TTVR in a real-world setting was associated with significant symptom and end-organ functional improvement. Patients with massive or torrential TR were more likely to experience functional improvement. Pre-existing conduction disturbances are associated with increased risk for pacemaker implantation, while baseline right ventricular dysfunction is a strong predictor of adverse clinical outcomes.
19 December 2022 in JACC: Cardiovascular Interventions
Since its introduction in 2003, Abbott's MitraClip (MC) has become the most established catheter-based treatment for mitral regurgitation (MR). Recent approval of Edwards Lifescience's PASCAL device has extended the field of TEER. The aim of this retrospective multicenter study was to compare the PASCAL and MC regarding procedural results and short- and long-term outcomes after mitral valve transcatheter edge-to-edge repair (TEER). Data from 3 high-volume centers were analyzed. The primary endpoint was residual MR at discharge. Secondary endpoints were technical success, MR reduction, and 30-day mortality. After 1 year, all-cause mortality and residual MR were reported. A total of 412 patients (216 MC, 196 PASCAL) treated between 2018 and 2020 were included. A total of 184 patients (92 in each treatment group) remained after propensity score matching. The rate of baseline MR ≥3 was 98.9% in both groups (P = 1.00). Both TEER systems achieved equally high technical success rates (97.8%; P = 1.00), resulting in residual MR ≤1 in 69.6% vs 77.1% of patients (P = 0.24) and MR reduction by ≥2 grades in 83.7% vs 92.4% of patients (P = 0.13) using the MC and PASCAL, respectively. Thirty-day mortality was 1.1% in both cohorts (P = 0.98), and 1-year follow-up showed similar MR reductions (residual MR ≤1, 78.0% with MC vs 82.3% with PASCAL; P = 0.70) and comparable all-cause mortality (14.1% with MC vs 6.5% with PASCAL; P = 0.14). In multivariate regression analysis, Society of Thoracic Surgeons score independently correlated with an optimal result (MR ≤1), while device choice did not show a significant impact. In this retrospective multicenter study, the established MC and the novel PASCAL mitral valve TEER systems were safe and offered excellent performance with comparable short- and long-term outcomes.
Background: The development of transcatheter tricuspid edge-to-edge repair for tricuspid regurgitation is a therapeutic milestone but a specific periprocedural risk assessment tool is lacking. TRI-SCORE has recently been introduced as a dedicated risk score for tricuspid valve surgery. Aims: This study analyzes the predictive performance of TRI-SCORE following transcatheter edge-to-edge tricuspid valve repair. Methods: 180 patients who underwent transcatheter tricuspid valve repair at Ulm University Hospital were consecutively included and stratified into three TRI-SCORE risk groups. The predictive performance of TRI-SCORE was assessed throughout a follow-up period of 30 days and up to 1 year. Results: All patients had severe tricuspid regurgitation. Median EuroSCORE II was 6.4% (IQR 3.8–10.1%), median STS-Score 8.1% (IQR 4.6–13.4%) and median TRI-SCORE 6.0 (IQR 4.0–7.0). 64 patients (35.6%) were in the low TRI-SCORE group, 91 (50.6%) in the intermediate and 25 (13.9%) in the high-risk groups. The procedural success rate was 97.8%. 30-day mortality was 0% in the low-risk group, 1.3% in the intermediate-risk and 17.4% in the high-risk groups (p < 0.001). During a median follow-up of 168 days mortality was 0%, 3.8% and 52.2%, respectively (p < 0.001). The predictive performance of TRI-SCORE was excellent (AUC for 30-day mortality: 90.3%, for one-year mortality: 93.1%) and superior to EuroSCORE II (AUC 56.6% and 64.4%, respectively) and STS-Score (AUC 61.0% and 59.0%, respectively). Conclusion: TRI-SCORE is a valuable tool for prediction of mortality after transcatheter edge-to-edge tricuspid valve repair and its performance is superior to EuroSCORE II and STS-Score. Graphical