Yuseop Sim

Mr. Yuseop Sim

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2025 in Journal of Manufacturing Systems
Verified
Journal Article
Closed access
JJJurim Jeon
Jurim Jeon
YSYuseop Sim
Yuseop Sim
HLHojun Lee
Hojun Lee
CHChangheon Han
Changheon Han
DYDongjun Yun
Dongjun Yun
JLJiho Lee
Jiho Lee

31 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
YSYuseop Sim
Yuseop Sim
JKJaehwan Kong
Jaehwan Kong
SCSeong-sig Choi
Seong-sig Choi
HYHak Yi
Hak Yi
Rehabilitation robotics faces the challenges of aligning engineering design with patient-specific needs. Most existing controllers in rehabilitation robots often constrain motion to fixed paths or provide only passive guidance, limiting user engagement and adaptability. This study proposes a novel active-assistive mode controller that integrates a virtual tunnel-based force generation mechanism with a dynamic moving-window technique for tracking activities of daily living (ADL) trajectories. Unlike conventional impedance controllers, the proposed method dynamically adjusts the virtual tunnel in real time, permitting voluntary upper-limb movement within a safe operational range while preventing excessive deviation. The system was implemented on a wearable two-degree-of-freedom (DOF) upper-limb exoskeleton equipped with drive and integrated sensor units. Experimental results demonstrated that decreasing the guidance force (Fgf) increased tracking errors, from 1° at 100% Fgf to 5° at 30% Fgf, indicating greater voluntary participant motion. Peak actuator torques correspondingly decreased from 14.75 to 13.43 Nm (elbow) and from 4.14 to 2.48 Nm (wrist), confirming the controller’s capability to modulate robotic assistance according to user effort. Tests with 30 healthy participants demonstrated the effectiveness of guidance along predefined ADL trajectories, validating the controller’s potential for patient-centered rehabilitation.


7 August 2026 in Journal of Manufacturing Systems
Verified
Journal Article
Closed access
HLHojun Lee
Hojun Lee
YSYuseop Sim
Yuseop Sim
JJJunmyoung Jang
Junmyoung Jang
BYByoungkwon Yoon
Byoungkwon Yoon
HLHan Gyeom Lee
Han Gyeom Lee
MJMartin Jun
Martin Jun

13 April 2026 in Journal of Intelligent Manufacturing
Verified
Journal Article
Closed access
HLHojun Lee
Hojun Lee
CHChangheon Han
Changheon Han
TGTed Gabor
Ted Gabor
YSYuseop Sim
Yuseop Sim
Semih AkinSemih Akin
Semih Akin
JLJiho Lee
Jiho Lee

1 January 2026 in International Journal of Advanced Robotic Systems
Verified
Journal Article
Open access
JKJaehwan Kong
Jaehwan Kong
YSYuseop Sim
Yuseop Sim
HYHak Yi
Hak Yi
The implementation of an upper-limb rehabilitation simulator replicating patient-specific physical characteristics has garnered increasing interest as an effective alternative to human subjects for medical training and research. However, human upper-limb motion involves complex multi-joint coordination, whereas most existing patient simulators reproduce simplified mechanical properties of individual joints and often fail to mimic critical pathological characteristics, such as rigidity and physiological tremors. This study addresses these limitations by proposing a novel simulator that incorporates both compound joint coordination and patient-specific symptoms (e.g. lead-pipe rigidity and physiological tremors). A motion control system based on a linear quadratic regulator was designed, with patient-specific reference torques derived from adult male motion-capture data. The tremor parameters were selected within the range reported in neurophysiological literature, and rigidity was implemented based on spasticity-inspired torque models. The proposed controller achieved torque-tracking errors below 3%, while reproducing clinically relevant peak torque levels of 18–20 Nm at the shoulder and 3–7 Nm at the elbow under manual muscle testing–grade scaling. The experimental evaluations across rigidity levels highlighted the reliability and effectiveness of the proposed simulator in accurately mimicking patient characteristics, making it a practical alternative for patients in rehabilitation training. Additionally, a clinical similarity survey was conducted with eight rehabilitation specialists and 10 students following a standardized, blinded protocol, yielding a mean rating of 9.33 ± 0.72 and a significant group effect (analysis of variance F ( 2 , 57 ) = 12.83 , p < 0.001 ). To the best of our knowledge, this study is the first to combine multi-joint coordination with the simultaneous reproduction of rigidity and physiological tremors in a two-degree-of-freedom upper-limb robotic replica, demonstrating the novelty and practical value of the approach.