Marianne Rodgers

Dr. Marianne Rodgers


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
EREldrich Rebello
Eldrich Rebello
DWDavid Watson
David Watson
MRMarianne Rodgers
Marianne Rodgers

15 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
S. C. PryorS. C. Pryor
S. C. Pryor
RBRebecca J Barthelmie
Rebecca J Barthelmie
JCJeremy Cadence
Jeremy Cadence
EDEbba Dellwik
Ebba Dellwik
CHCharlotte Hasager
Charlotte Hasager
MVMarijn Veraart
Marijn Veraart
Leading edge erosion (LEE) of wind turbine blades causes decreased aerodynamic performance leading to lower power production and revenue and increased operations and maintenance costs. LEE is caused primarily by materials stresses when hydrometeors (rain and hail) impact on rotating blades. The kinetic energy transferred by these impacts is a function of the precipitation intensity, droplet size distributions (DSD), hydrometeor phase and the wind turbine rotational speed which in turn depends on the wind speed at hub-height. Hence, there is a need to better understand the hydrometeor properties and the joint probability distributions of precipitation and wind speeds at prospective and operating wind farms in order to quantify the potential for LEE and the financial efficacy of LEE mitigation measures. However, there are relatively few observational datasets of hydrometeor DSD available for such locations. Here, we analyze six observational datasets from spatially dispersed locations and compare them with existing literature and assumed DSD used in laboratory experiments of material fatigue. We show that the so-called Best DSD being recommended for use in whirling arm experiments does not represent the observational data. Neither does the Marshall Palmer approximation. We also use these data to derive and compare joint probability distributions of drivers of LEE; precipitation intensity (and phase) and wind speed. We further review and summarize observational metrologies for hydrometeor DSD, provide information regarding measurement uncertainty in the parameters of critical importance to kinetic energy transfer and closure of data sets from different instruments. A series of recommendations are made about research needed to evolve towards the required fidelity for a priori estimates of LEE potential.

8 May 2017 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
TCTapabrata Chakraborty
Tapabrata Chakraborty
DWDavid Watson
David Watson
MRMarianne Rodgers
Marianne Rodgers
This paper demonstrates the operation of a 1 MW/2 MWh grid-tied battery energy storage system (BESS) in a 10 MW wind R&D park for Automatic Generation Control (AGC) for 29 days. The efficiency and utilization of the BESS in the context of regulation and grid integration are examined. The response time for the BESS is as low as one second, which is faster than the current accepted practice of a conventional generator with governor control. Using PJM's performance template gives an average performance score of 93% while the storage is providing AGC. However, because the storage system only charges when there is sufficient wind energy and spent significant time in maintenance mode, the 29-day performance average is only 65%. The battery was able to carry out some mode of AGC for 64% of the test period. When energy costs and battery degradation are considered, utilizing the battery costs USD 19,000 over the 29-day period, whereas the potential income from AGC, charging only with wind power, was USD 9,037. This 29-day demonstration shows that batteries have fast response and can perform AGC, but within a wind farm AGC is unlikely to be suitable without changes in the tariff schemes.

31 August 2017 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
DWDavid Watson
David Watson
CHCameron Hastie
Cameron Hastie
MRMarianne Rodgers
Marianne Rodgers
Regulation is required to ensure that energy generation and demand on an electricity grid match at all times. Energy storage has been proposed to provide fast, precise regulation as wind energy and other renewable energies displace traditional generators that also provide regulation. In this investigation, different levels of regulation are offered using a 1 MW/2 MWh battery to determine the optimal offering for the system. The sodium-nickel chloride (Na-NiCl 2 ) battery is charge rate limited, which affects the accuracy, especially at high states of charge. Offering a lower regulation capability increases the accuracy in the same state of charge range, but results in lower payments. Performing regulation behind the meter of a wind farm causes additional challenges due to the current electricity rate structure, which has a high demand charge during low wind generation periods. This causes the storage system to be limited to wind generation periods, resulting in regulation not being offered every hour. The battery achieved PJM performance scores above 90% while performing regulation, with month-long averages ranging from 59% to 63%, depending on the regulation offered. The maximum monthly revenue under the described operation, using PJM's regulation rates, is under 50% of the monthly cost of the Wind Energy Institute of Canada's USD 2.34 million dollar battery energy storage system.

22 June 2017 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
DWDavid Watson
David Watson
CHCameron Hastie
Cameron Hastie
BGBrady Gaudette
Brady Gaudette
MRMarianne Rodgers
Marianne Rodgers
This paper describes the demonstration and evaluation of stacking wind power time-shifting and regulation by a 1 MW/2 MWh Battery Energy Storage System (BESS) within a 10 MW wind park. The BESS time-shifted 15.8 MWh of wind power to peak periods while responding to the automatic generation control (AGC) signals that provide regulation over the 24 day test period. Its fast response time and accurate output allowed the BESS to provide both services simultaneously. Limiting the charging to periods when wind power was available lowered the amount of time-shifting and AGC that could be provided. Some form of AGC was delivered from the BESS for 78.5% of the test period and, if it were remunerated at the PJM rate when the test was performed, it would have earned 8627 USD, with 97% from regulation and the rest from time-shifting wind power. Using PJM's performance template, the BESS averaged a performance score of 70.5% during hours when regulation was performed. This work adds to the growing empirical data that is informing models of and policy for grid storage.

1 April 2019 in Journal of Energy Storage
Verified
Journal Article
Closed access
DWDavid Watson
David Watson
MRMarianne Rodgers
Marianne Rodgers