Infectious complications following left ventricular assist device implantation can carry significant morbidity and mortality. The main tenet of treatment is source control which entails local wound care, intravenous antimicrobial therapy, surgical debridement, and at times, soft tissue flap coverage. The mode of therapy depends on the severity, etiology, and location of infection as well as the clinical status of the patient. We describe a case of a 46‐year‐old male who underwent left ventricular assist device placement complicated by pump thrombosis, recurrent infection, and hardware exposure who was successfully treated with a novel method of staged, soft tissue reconstruction.
Peripheral extracorporeal membrane oxygenation (ECMO) is one of the most common strategies for cardiogenic shock. ECMO cannulation is associated with an increased risk of complications. We describe a minimally invasive, off-pump technique to provide adequate hemodynamic support and left ventricular unloading. A 54-year-old male with nonischemic cardiomyopathy and severe peripheral vascular disease with cardiogenic shock was initially supported with inotropes and an intra-aortic balloon pump. Despite continued support, he continued to deteriorate, and we escalated to a temporary left ventricular support with a CentriMag, using a transapical ProtekDuo Rapid Deployment cannula via mini left-thoracotomy. This approach provides adequate hemodynamic support, left ventricular unloading and early ambulation. After 9 days, the patient’s functional status was improved and was medically optimized. The patient received a left ventricular assist device as destination therapy. He was discharged home, resumed his normal activities and has been doing well for more than 27 months.
10 December 2022 in Annals of Thoracic Surgery Short Reports
Lung transplantation is associated with a higher morbidity and mortality compared with transplantation of other solid organs, which is related, in part, to the occurrence of airway complications. A bronchoesophageal fistula associated with dehiscence of the right bronchial anastomosis developed in a 59-year-old man after bilateral lung transplantation. Multiple endoscopic and bronchoscopic stent procedures failed to close the fistula. Five months after the lung transplant, the fistula was successfully closed with an Amplatzer ADO septal occluder device. One year later, the fistula was still closed, but because of the development of multiple gastrointestinal complications, the patient received palliative care.
5 January 2026 in Journal of Cardiothoracic Surgery
Percutaneous coronary intervention of calcified coronary lesions is fraught with short-term and long-term risks. Judicious use of adjunct intracoronary ima