Symptoms of essential tremor (ET) are similar to those of Parkinson’s disease (PD) during their initial stages. Presently, there are few stable biomarkers available on a neuroanatomical level for distinguishing between these two diseases. However, few investigations have directly compared the changes in brain volume and assessed the compensatory effects of a change in the parts of the brain associated with PD and with ET. To determine the compensatory and/or degenerative anatomical changes in the brains of PD and ET patients, the present study tested, via two VBM approaches (Basic vs. Dartel VBM processing), the anatomical brain images of 10 PD and 10 ET patients, as well as of 13 age-matched normal controls, obtained through a 3T magnetic resonance scanner. These findings indicate that PD and ET caused specific patterns of brain volume alterations in the brains examined. In addition, our observations also revealed compensatory effects, or self-reorganization, occurring in the thalamus and the MTG in the PD and ET patients, due perhaps in part to the enhanced thalamocortical sensorimotor interaction and the head-eye position readjustment, respectively, in these PD and ET patients. Such a distinction may lend itself to use as a biomarker for differentiating between these two diseases.
Direct binary search (DBS) produces the images of the best quality among half-toning algorithms. The reason is that it minimizes the total squared perceived error instead of using heuristic approaches. The search for the optimal solution involves two operations: (1) toggle and (2) swap. Both operations try to find the binary states for each pixel to minimize the total squared perceived error. This error energy minimization leads to a conjecture that the absolute value of the filtered error after DBS converges is bounded by half of the peak value of the autocorrelation filter. However, a proof of the bound's existence has not yet been found. In this paper, we present a proof that shows the bound existed as conjectured under the condition that at least one swap occurs after toggle converges. The theoretical analysis also indicates that a swap with a pixel further away from the center of the autocorrelation filter results in a tighter bound. Therefore, we propose a new DBS algorithm which considers toggle and swap separately, and the swap operations are considered in the order from the edge to the center of the filter. Experimental results show that the new algorithm is more efficient than the previous algorithm and can produce half-toned images of the same quality as the previous algorithm.
1 July 2000 in IEEE Transactions on Medical Imaging
Because spiral magnetic resonance imaging (MRI) is more robust to motion artifacts than echo planar imaging (EPI), spiral imaging method is more suitable in real-time imaging applications where dynamic processes are to be observed. The major hurdle to use spiral imaging method in real-time applications is its slow reconstruction speed. Since spiral trajectories do not sample data on rectilinear grids, raw data must be regridded before inverse fast Fourier transform (FFT). At present, the computational cost for the spiral reconstruction algorithm is still too high and it is not fast enough to achieve the minimum speed requirement of 20 frames/s for real-time imaging applications. In this paper, we propose to replace floating-point calculations with fixed-point calculations in the reconstruction algorithm to remove the computational bottlenecks. To overcome the quantization and round-off errors introduced by fixed-point calculations, we devise a method to find the optimal precision for the fixed-point representation. Adding with a highly efficient vector-radix two-dimensional (2-D) FFT algorithm and modifications to speed up the gridding convolution, we have cut the reconstruction time by 42% and achieved real-time reconstruction at 30 frames/s for 128 x 128 matrices on low-cost PC's.
29 October 2022 in Multidimensional Systems and Signal Processing