Stability of nominal frequency and voltage level in an electric power system is the primary control issue of practicing engineers. Any deterioration in these two parameters will affect the performance and life expectancy of the associated machinery to the power system. Hence, controllers are installed and set for a specific working situation and deal with small variations in load demand to keep the frequency and terminal voltage magnitude within the permissible limits. As the system performance can be improved with selecting suitable controller, an attempt has been made to design fractional-order PID (FOPID) controller for combined frequency and voltage control problems. This paper presents plan and execution examination of FOPID controller for simultaneous load frequency and voltage control of power system using recently developed nature-motivated powerful optimization technique, i.e., moth flame optimization algorithm. The first part of the present work demonstrates the implementation of the proposed technique on frequency stabilization of isolated power system with AVR for excitation voltage control. The superiority and effectiveness of the proposed approach are tested by comparing the dynamic response of the system with PID controllers optimized by other intelligent techniques. Then the present work is extended to multi-unit two-area power system. The tuning ability of the algorithm is extensively and comparatively investigated.
Electric power distribution system planning is a key area of concentration for developing more efficient, trustworthy, and environmentally friendly energy sources in the future. While distributed generations (DGs) are excellent at reducing system actual power losses, shunt capacitors can supplement their effectiveness when utilized in tandem. It is feasible to achieve even higher reductions in power losses and enhanced system efficiency by combining DGs with shunt capacitors. The Loss Sensitivity Factor (LSF) measures how sensitive real power loss in a network is to changes in power injection (active or reactive power) at a single bus. The methodology analyses LSFs to assess the ideal sites for placing DGs and capacitors in radial distribution networks (RDNs). The Golden Jackal Optimization (GJO) strategy is adopted to discover the ideal sizing and allocation of DGs and capacitors. The strategy is tested using two RDNs, one with 33 buses and the other with 69 buses. In addition, five major technical indices are explored and examined, used as an evaluation criterion to distinguish between the optimal and baseline performances. These are the voltage deviation index (VDI), power loss index (PLI), fast voltage stability index (FVSI), line stability factor (LQP), and novel line stability index (NLSI). Voltage deviation, power loss, and voltage stability analysis-related indices are among the technical characteristics addressed.
This article introduces an intelligent framework using deep learning to recognize and classify different faults through the real-time detection of multiple faults in power distribution systems. A collection of data representing normal operating conditions, alongside various fault scenarios including line-to-ground (LG), line-to-line (LL), double line-to-ground (LLG), and three-phase line (LLL) faults, was created using three phase current signals obtained from the Real-Time Digital Simulator (RTDS) microgrid test system. To properly model the system dynamics, a feature extraction method that integrates phase currents, differential currents, summation currents and magnitude results was developed. The temporal features of the fault signals were identified by using a sliding window approach to fit the data. A one-dimensional convolutional neural network (CNN) was developed to identify different types of faults. This model performed well, obtaining nearly 96.15% accuracy while testing. In order to evaluate the feasibility of the approach, the trained model was loaded on Raspberry Pi 5, NodeMCU, ESP32 and existing sensing devices. The fault classification performed in real-time was time-sensitive. The proposed intelligent framework is applicable to low-scale operation for smart grid fault monitoring and protection and it is an economically viable solution.
Fault detection in microgrids is a critical element of system stability and uninterrupted power delivery. Herein, a comparative study using LSTM and bidirectional LSTM networks is performed based on three-phase current data for multi-class fault classification. Five major fault types, namely LG, LL, LLG, LLL, and LLLG, were simulated using a Real-Time Digital Simulator (RTDS) under grid-connected and islanded modes. Collected current signals were preprocessed, normalized, and segmented for sequence learning. Later, both models were trained using the best hyperparameter setting to enhance their capabilities and classify faults. To measure how well they identified faults, evaluation metrics, like accuracy, precision, recall, F1-score, and ROC-AUC, were calculated. The results revealed that the Bi-LSTM outperformed the LSTM and classical machine learning models consistently, with more than 99% accuracy for most fault types. More importantly, the proposed framework also checked classification performance for LLLG faults, with the Bi-LSTM model having a test accuracy of 98.8%. These results confirm that the Bi-LSTM model can robustly and precisely classify and detect faults in real time within specific phases of microgrids; therefore, it provides a scalable foundation for the development of intelligent protection in smart power systems.