To accurately simulate the chloride ion diffusion process in concrete containing mineral admixtures under coupled multi-factor effects, a cellular automata (CA)-based numerical model is developed to predict the chloride ion concentration at different depths and exposure times. The proposed model incorporates the influences of spatiotemporal variability, stress state, and admixture replacement ratio into the evolution rules of chloride transport. Accordingly, the time-dependent chloride diffusion coefficient is modified to account for the effects of fly ash and slag, enabling a more realistic representation of chloride transport behavior in admixture-modified concrete. Long-term field exposure test data reported in the literature are adopted to validate the proposed model. The simulated chloride concentration profiles at various depths and exposure durations show good agreement with experimental measurements, particularly at medium-to-long exposure ages. The results demonstrate that the CA model provides a reasonable and effective way for simulating chloride ion ingress in concrete with mineral admixtures. Furthermore, under comparable strength conditions, an increase in slag replacement ratio leads to enhanced resistance against chloride ion ingress, highlighting the significant role of mineral admixtures in improving the durability performance of concrete structures.
Deep excavations in composite “soft upper-hard lower” strata present significant deformation control challenges due to strong stiffness contrasts. This study investigates the deformation characteristics of a deep metro foundation pit in Jinan under zoned excavation conditions. A three-dimensional finite element model was developed to simulate the staged excavation process, and the spatiotemporal evolution of diaphragm wall deflection and ground settlement was analyzed, with particular focus on the influence of soft soil thickness. The results show clear spatial variation, with maximum lateral wall displacements exhibiting a typical “bulging” profile along the longer sides of the pit. The normalized maximum wall displacement (δhm/He) ranges from 0.051% to 0.090%, while the ratio of maximum ground settlement to wall displacement is 0.35–0.57, indicating lower deformation levels compared to homogeneous soft soils. As the soft soil thickness increases, the wall displacement increases and the location of maximum displacement migrates downward and outward. Under the investigated conditions, a transition toward a “kick-out” deformation mode occurs when the soft soil thickness reaches the transition range identified in the parametric analysis. These findings provide a quantitative basis for deformation prediction and support design in composite strata.
Steel–UHPC composite beams are widely used in bridge engineering due to their high strength, durability, and suitability for prefabricated construction. However, the mechanical performance of shear connectors in UHPC differs significantly, and the uniform use of a single connector type along the beam span may result in a mismatch between connector mechanical characteristics and regional force demands, leading to suboptimal force transfer and inefficient utilization of connector capacity along the beam span. While previous studies have mainly focused on the local behavior of individual connectors, a system-level design strategy considering regional force demands is still limited. This study proposes a system-level design method for combined shear connectors in steel–UHPC composite beams, in which headed stud connectors and trapezoidal composite dowel connectors are arranged according to bending moment distribution and interface shear demand, thereby integrating connector mechanical characteristics with the spatial variation in internal forces along the beam span. The design procedure includes shear span division, longitudinal interface shear calculation, and resistance verification of different connector types. The method is applied to a practical steel–UHPC composite beam in a long-span approach bridge. Results show that headed studs provide reliable uplift resistance and ductile behavior in negative bending regions, whereas composite dowel connectors are shown to be more suitable for shear-dominated positive bending regions due to their higher shear capacity and stiffness. The combined system ensures effective composite action under different stress states and reduces total connector steel consumption compared with a stud-only layout. The proposed approach advances connector design toward performance-oriented and system-level structural optimization, providing a practical framework for connector arrangement in steel–UHPC composite beams.