Seiji Kumagai

Prof. Seiji Kumagai

Department of Mathematical Science and Electrical-Electronic-Computer Engineering, Akita University, Akita City, Japan
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2001 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Seiji KumagaiSeiji Kumagai
Seiji Kumagai
NYN. Yoshimura
N. Yoshimura
Tracking and erosion of high temperature vulcanizing (HTV)-silicone rubber (SIR) and the suppression mechanism of alumina trihydrate (ATH) filler were investigated in the present study. The tracking and erosion resistance of HTV-SIR filled with 0 to 60%wt ATH was evaluated by employing an IEC 587 inclined plane (IP) tracking and erosion test, during which leakage current pulses on HTV-SIR were counted. Surface temperature distributions and the occurrences of thermal spots >400/spl deg/C also were observed by means of an infrared thermovision study. We employed thermogravimetry (TG)-differential thermal analysis (DTA)-mass spectrometer (MS) to observe the thermal degradation of unfilled and filled HTV-SIR in both air and argon. The test results indicate that 40%wt is a critical ATH level and whether tracking and erosion is allowed in the IP tracking and erosion test. Highly filling ATH (>40%wt) reduces the number of low unit silicone oligomer precursors which promote dry-band arcing as well as the presence of residual carbon which leads to carbonization. Chemical modifications of water vapor liberated from heated ATH to methyl groups, which occurs at the thermal decomposition temperature of silicone rubber, were found to result in the above process. The protection mechanisms of ATH for the tracking and erosion of HTV-SIR are formulated herein.

1 January 1999 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
NYN. Yoshimura
N. Yoshimura
Seiji KumagaiSeiji Kumagai
Seiji Kumagai
SNS. Nishimura
S. Nishimura

1 December 2013 in Electrochimica Acta
Verified
Journal Article
Closed access
Seiji KumagaiSeiji Kumagai
Seiji Kumagai
MSMasashi Sato
Masashi Sato
DTDaisuke Tashima
Daisuke Tashima

24 August 2004 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Seiji KumagaiSeiji Kumagai
Seiji Kumagai
NYN. Yoshimura
N. Yoshimura
Leakage current produced on contaminated ceramic and polymeric insulating surfaces was analyzed using a wavelet transform technique providing time-frequency domain information. Salt-fog tests with and without the deposition of non-soluble contamination were conducted in a laboratory, during which the leakage current was separated into sinusoidal, local arc, or their transition components per halfwave of power frequency. The wavelet transform allowed the detection of the zero-cross point of the base current at 50 Hz without the need for voltage information. The source information regarding the distortion level (I/sub 150 Hz//I/sub 50 Hz/) of the current half-wave separated by the zero-cross point and a time lag to onset in current attributable to arcs are used in order to obtain the above three components. The time-integrated values (cumulative charges) of these components were found to correlate with hydrophobicity and contamination level. It was shown that time variations of the cumulative charges and of their component ratios were useful for estimating the conditions of ceramic and polymeric insulating surfaces.

27 November 2019 in Energies
Verified
Journal Article
Open access
PDF file
YAYusuke Abe
Yusuke Abe
NHNatsuki Hori
Natsuki Hori
Seiji KumagaiSeiji Kumagai
Seiji Kumagai
Lithium-ion batteries (LIBs) using a LiFePO4 cathode and graphite anode were assembled in coin cell form and subjected to 1000 charge-discharge cycles at 1, 2, and 5 C at 25 °C. The performance degradation of the LIB cells under different C-rates was analyzed by electrochemical impedance spectroscopy (EIS) and scanning electron microscopy. The most severe degradation occurred at 2 C while degradation was mitigated at the highest C-rate of 5 C. EIS data of the equivalent circuit model provided information on the changes in the internal resistance. The charge-transfer resistance within all the cells increased after the cycle test, with the cell cycled at 2 C presenting the greatest increment in the charge-transfer resistance. Agglomerates were observed on the graphite anodes of the cells cycled at 2 and 5 C; these were more abundantly produced in the former cell. The lower degradation of the cell cycled at 5 C was attributed to the lowered capacity utilization of the anode. The larger cell voltage drop caused by the increased C-rate reduced the electrode potential variation allocated to the net electrochemical reactions, contributing to the charge-discharge specific capacity of the cells.

1 January 2007 in Waste Management
Verified
Journal Article
Closed access
Seiji KumagaiSeiji Kumagai
Seiji Kumagai
YNYosuke Noguchi
Yosuke Noguchi
YKYasuji Kurimoto
Yasuji Kurimoto
KTKoichi Takeda
Koichi Takeda