A comparison of the radiation exposure to the left anterior descending artery (LAD) and left ventricle (LV) was performed for twenty-three left breast cancer patients. For each participant, two tangential fields 3D-CRT, two- and seven-field IMRT and two and four partial arcs VMAT plans were created. Dose constraints for CTV, ipsilateral lung and heart were followed. The V40Gy, V30Gy, Dav of LAD and V23Gy, V5Gy, Dav of LV were calculated and extracted from the plans. Parametric and non-parametric tests were applied to compare the parameters derived from the five treatment techniques. All generated plans fulfilled the dose constraints. The Dav ranges of the LAD and LV from all examined techniques were 11.77–14.73 Gy and 5.37–6.40 Gy, respectively. The V40Gy and V30Gy ranges of the LAD were 2.90–12.91% and 10.80–18.51%, respectively. The V23Gy and V5Gy of the LV were 4.29–7.43% and 18.24–30.05%, respectively. The VMAT plans and seven-field IMRT significantly reduced the V40Gy, V30Gy of LAD and V23Gy of LV compared with the two-field treatments (p < 0.05). However, 3D-CRT plans provided statistically lower values for V5Gy of LV over the other techniques (p < 0.05). The presented results provide a detailed dataset of the radiation burden of two critical cardiac structures from five radiotherapy techniques.

19 March 2026 in Medical Sciences
Verified
Journal Article
Open access
PDF file
EKEvgenia Konstantinou
Evgenia Konstantinou
ELEfrossyni Lyraraki
Efrossyni Lyraraki
MMMichalis Mazonakis
Michalis Mazonakis
Objectives: To evaluate the effectiveness of different optimization parameters on radiotherapy plan quality for seventeen head and neck cancer patients. Methods: Volumetric Modulated Arc Therapy with Simultaneous Integrated Boost (VMAT-SIB) plans, involving up to three tumors, were generated. For each participant, a reference plan (Plan_Ref) was created using dual-arc with 180 control points, 20° gantry-angle increment and 1 cm minimum segment width. Modified plans were developed with dose constraints and optimization settings constant by changing to single-arc, 150 and 200 control points, 0.5 cm minimum segment width, and 30° and 40° gantry-angle increments. These plans were referred to as Plan_Arc1, Plan_CP150, Plan_CP200, Plan_SW0.5, Plan_Inc30, and Plan_Inc40, respectively. D95% of planning target volumes (PTVs), homogeneity index (HI), monitor units (MUs), maximum dose (Dmax) of spinal cord, mandible, and brainstem were recorded. Statistical and Bland–Altman analysis was performed comparing the modified plans to Plan_Ref. Results: Average D95% values for PTV1, PTV2, and PTV3 ranged from 93.13 to 98.82%. Plan_SW0.5 provided superior target coverage and homogeneity with higher MUs than Plan_Ref. Plan_Arc1 significantly reduced PTV coverage and dose homogeneity, while increasing MUs compared with Plan_Ref (p < 0.05). The average Dmax as derived from all planning approaches was up to 43.86 Gy, 65.86 Gy, and 48.85 Gy for spinal cord, mandible and brainstem, respectively. For spinal cord, Plan_Ref led to significantly lower doses compared to Plan_Arc1 and Plan_Inc30, while the brainstem recorded statistically higher Dmax doses than Plan_Arc1. Significantly higher Dmax was observed for the mandible using Plan_SW0.5 (p < 0.05). However, for Dmax, the comparison plans showed good agreement with Plan_Ref based on Bland–Altman analysis. Conclusions: The VMAT plan quality is strongly affected by the minimum segment width whereas no differences were observed with the modification of the number of control points.