Bor-Shiunn Lee

Prof. Bor-Shiunn Lee


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2002 in Journal of Endodontics
Verified
Journal Article
Closed access
PDF file
ULUei-Ming Li
Uei-Ming Li
BLBor-Shiunn Lee
Bor-Shiunn Lee
CSChin-Tsai Shih
Chin-Tsai Shih
WLWan-Hong Lan
Wan-Hong Lan
CLChun-Pin Lin
Chun-Pin Lin
Endodontic instruments upon rotation are subjected to both tensile and compressive stress in curved canals. This stress is localized at the point of curvature. The purpose of this study was to evaluate the cyclic fatigue of 0.04 ProFile® nickel titanium rotary instruments operating at different rotational speeds and varied distances of pecking motion in metal blocks that simulated curved canals. A total of 150 ProFile® instruments were made to rotate freely in sloped metal blocks at speeds of 200, 300, or 400 rpm by a contra-angle handpiece mounted on an Instron machine. The electric motor and Instron machine were activated until the instruments were broken in two different modes, static and dynamic pecking-motion. The fractured surfaces of separated instruments were examined under a scanning electron microscope. All data obtained were analyzed by a stepwise multiple regression method using a 95% confidence interval. The results demonstrated that the time to failure significantly decreased as the angles of curvature or the rotational speeds increased. However, as pecking distances increased, the time to failure increased. This is because a longer pecking distance gives the instrument a longer time interval before it once again passes through the highest stress area. Microscopic evaluation indicated that ductile fracture was the major cyclic failure mode. To prevent breakage of a NiTi rotary instrument, appropriate rotational speeds and continuous pecking motion in the root canals are recommended.

1 May 2007 in Dental Materials
Verified
Journal Article
Closed access
BLBor-Shiunn Lee
Bor-Shiunn Lee
PLPo-Yen Lin
Po-Yen Lin
MCMin-Huey Chen
Min-Huey Chen
THTseng-Ting Hsieh
Tseng-Ting Hsieh
CLChun-Pin Lin
Chun-Pin Lin
WLWan-Hong Lan
Wan-Hong Lan

1 March 2004 in Journal of Endodontics
Verified
Journal Article
Closed access
WLW Lan
W Lan
BLBor-Shiunn Lee
Bor-Shiunn Lee
HLH Liu
H Liu
CLC Lin
C Lin
Our previous in vitro study indicated that Nd:YAG laser irradiation on dentin could melt normal dentin surface and close the exposed dentinal tubule orifices without creating surface cracks. This study evaluated the morphologic changes of hypersensitive dentin after Nd:YAG laser irradiation. Thirty patients with clinically diagnosed cervical dentin hypersensitive teeth were treated with a Nd:YAG laser of 30 mJ intensity at 10 pulses per second for 2 min. An impression of the sensitive area was taken before and after laser treatment and then examined with a scanning electron microscope. The impression of the dentin surface after Nd:YAG laser treatment showed no protrusive rods, in contrast with the presence of numerous rods before laser irradiation. Because protrusive rods are a measure of open dentinal tubules, we interpret these data to support the hypothesis that Nd:YAG laser irradiation at specifications of 30 mJ, 10 pulses per second, and 2 min can be used to seal the exposed dentinal tubules.

1 April 2010 in Journal of the Formosan Medical Association
Verified
Journal Article
Closed access
CHChih-Chia Huang
Chih-Chia Huang
YCYa-Chi Chang
Ya-Chi Chang
MCMeng-Che Chuang
Meng-Che Chuang
TLTat-Minc Lai
Tat-Minc Lai
JLJuin-Yih Lai
Juin-Yih Lai
CLChun-Pin Lin
Chun-Pin Lin

1 June 2001 in Journal of Endodontics
Verified
Journal Article
Closed access
PDF file
CLChun-Pin Lin
Chun-Pin Lin
BLBor-Shiunn Lee
Bor-Shiunn Lee
FLFeng-Huei Lin
Feng-Huei Lin
SKSang-Heng Kok
Sang-Heng Kok
WLWan-Hong Lan
Wan-Hong Lan
Although techniques for repairing root fracture have been proposed, the prognosis is generally poor. If the fusion of a root fracture by laser is possible, it will offer an alternative to extraction. Our group has attempted to use lasers to fuse a low melting-point bioactive glass to fractured dentin. This report is focused on the phase, compositional, and morphological changes observed by means of X-ray diffractometer, Fourier transforming infrared spectroscopy, and scanning electron microscopy-energy dispersive X-ray spectroscopy in human dentin after exposure to Nd:YAG laser. The irradiation energies were from 150 mJ/pulse-10 pps-4 s to 150 mJ/pulse-30 pps-4 s. After exposure to Nd:YAG laser, dentin showed four peaks on the X-ray diffractometer that corresponding to α-tricalcium phosphate (TCP) and β-TCP at 2θ = 30.78 degrees/34.21 degrees and 32.47 degrees/33.05 degrees, respectively. The peaks of α-TCP and β-TCP gradually increased in intensity with the elevation of irradiation energy. In Fourier transforming infrared analysis, two absorption bands at 2200 cm−1 and 2015 cm−1 could be traced on dentin treated by Nd:YAG laser with the irradiation energies beyond 150 mJ/pulse-10 pps-4 s. The energy dispersive X-ray results showed that the calcium/phosphorus ratios of the irradiated area proportionally increased with the elevation of irradiation energy. The laser energies of 150 mJ/pulse-30 pps-4 s and 150 mJ/pulse-20 pps-4 s could result in the α-TCP formation and collagen breakdown. However, the formation of glass-like melted substances without α-TCP at the irradiated site was induced by the energy output of 150 mJ/pulse-10 pps-4 s. Scanning electron micrographs also revealed that the laser energy of 150 mJ/pulse-10 pps-4 s was sufficient to prompt melting and recrystallization of dentin crystals without cracking. Therefore, we suggest that the irradiation energy of Nd:YAG laser used to fuse a low melting-point bioactive glass to dentin is 150 mJ/pulse-10 pps-4 s.

1 October 2016 in Carbohydrate Polymers
Verified
Journal Article
Closed access
BLBor-Shiunn Lee
Bor-Shiunn Lee
CLChien-Chen Lee
Chien-Chen Lee
HLHung-Pin Lin
Hung-Pin Lin
WSWei-An Shih
Wei-An Shih
WHWan-Ling Hsieh
Wan-Ling Hsieh
YCYi-Wen Chen
Yi-Wen Chen