Lyam Bailey

Dr. Lyam Bailey


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
LBLyam Bailey
Lyam Bailey
CKClara Knox
Clara Knox
TBTimothy Bardouille
Timothy Bardouille
Background: Optically pumped magnetometers (OPMs) have emerged as a promising technology for neuromagnetic recording in humans. Current state-of-the-art OPM systems are housed in large magnetically shielded rooms to reduce external electromagnetic noise and typically comprise sensor arrays covering the entire head. Such systems are extremely costly to purchase and install, and take up large amounts of physical space, which limits the accessibility of this technology to research groups with limited funding. Here we sought to evaluate the utility of a more accessible “starter” OPM system comprising a small cylindrical mu-metal shield and partial sensor coverage. Methods: Twelve participants underwent right-sided median nerve stimulation (MNS) intended to elicit ubiquitous sensorimotor responses: somatosensory-evoked fields (SEFs, comprising N20m, P35m and P60m components) and event-related (de)synchronization (ERD/ERS) of oscillatory neuronal rhythms in the mu and beta frequency ranges. Results: Following MNS, we observed robust N20m and P60m peaks, as well as the expected mu ERD and beta ERS effects. Moreover, these responses could be localized to expected cortical generators. However, we observed markedly lower SNR than that seen in state-of-the-art systems. We make recommendations for further improvements to this system and others like it.

11 September 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
LBLyam Bailey
Lyam Bailey
NRNatalie Rhodes
Natalie Rhodes
RSRobert A Seymour
Robert A Seymour
MBMatthew J Brookes
Matthew J Brookes
MTMargot J Taylor
Margot J Taylor
Cross-frequency coupling describes interactions between neural ensembles operating at different frequency bands, and has been proposed to underlie coordination of brain activity over multiple temporal and spatial scales. Phase amplitude coupling (PAC) describes modulation of the amplitude of high-frequency oscillations by the phase of low frequency oscillations. MEG work in adults has demonstrated that alpha-gamma PAC may support visual perception. However, very little work has investigated visual PAC in children, or the development of this process between childhood and adulthood. Here we investigated the development of PAC in a sample of 101 individuals, comprising 50 children (aged 2-13 years) and 51 adults (21-34 years). Participants completed a passive visual stimulation paradigm while neural responses were recorded using a wearable whole-head OPM-MEG system. Sensor-level data were spatially resolved to visual cortex, and we quantified coupling between the phase of low-frequency oscillations (5-13 Hz) and the amplitude of broadband gamma oscillations (28-100 Hz) in each participant. In the adult data, we identified a cluster of phase-amplitude frequency pairs (phase: 7-11 Hz, amplitude: 52-66 Hz) in which there was strong evidence for an increase in PAC following stimulus presentation relative to baseline. Within this cluster, the magnitude of stimulus-induced PAC was positively correlated with age across all participants. Meanwhile, we did not see credible evidence for visual PAC at any frequency pair(s) within the child group. These results suggest that, alongside well-documented developmental changes in band-specific oscillatory power and connectivity, visual PAC represents a distinct functional process which matures with age.

27 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
LBLyam Bailey
Lyam Bailey
CKClara Knox
Clara Knox
TBTimothy Bardouille
Timothy Bardouille
Background: Optically pumped magnetometers (OPMs) have emerged as a promising technology for neuromagnetic recording in humans. Current state-of-the-art OPM systems are housed in large magnetically-shielded rooms to reduce external electro-magnetic noise, and typically comprise sensor arrays covering the entire head. Such systems are extremely costly to purchase and install, and take up large amounts of physical space, which limits the accessibility of this technology to research groups with limited funding. Here we sought to evaluate the utility of a more accessible “starter” OPM system comprising a small cylindrical mu-metal shield and partial sensor cover-age. Methods: Twelve participants underwent right-sided median nerve stimulation (MNS) intended to elicit ubiquitous sensorimotor responses: somatosensory-evoked fields (SEFs; comprising N20m, P35m and P60m components) and event-related (de)synchronisation (ERD/ERS) of oscillatory neuronal rhythms in the mu and beta frequency ranges. Results: Following MNS, we observed robust N20m and P60m peaks, as well as the expected mu ERD and beta ERS effects. Moreover, these responses could be localized to expected cortical generators. However, we observed markedly lower SNR than that seen in state-of-the-art systems. We make recommendations for further improvements to this system and others like it.