Objectives: To describe the change in the caudal vena cava to aorta ratio (CVC:Ao) ratio during fluid resuscitation of circulatory shock in dogs and compare these results with those of the physical examination and blood lactate.Materials and Methods: Perfusion parameters and blood lactate were recorded at admission. An abdominal point‐of‐care ultrasound protocol was performed, during which the caudal vena cava to aorta ratio was measured on the spleno‐renal view. Measurements were performed within 5 minutes before and after a 10 mL/kg crystalloid fluid bolus. Investigators were not blinded to therapeutic interventions.Results: Twenty‐nine dogs with physical signs of circulatory shock were enrolled. Caudal vena cava to aorta ratios were below reference interval in 28 of 29 dogs. After bolus administration, median caudal vena cava diameter increased by 0.14 cm (0.69 to 0.83 cm) and median aorta diameter increased by 0.03 cm (0.87 to 0.90 cm) and caudal vena cava to aorta ratio returned to within reference range in 65% of dogs (13/29). Bolus administration was associated with an increase in median caudal vena cava to aorta ratio of 0.10 (95% CI:0.05 to 0.16, P=0.0005). Blood lactate did not change significantly. Heart rate and capillary refill time decreased significantly after fluid bolus (heart rate: estimate=−19 bpm, 95% CI:−30 to −8, P=0.002; capillary refill time: estimate=−1.0 s, 95% CI:−1.3 to −0.7, P < 0.0001).Clinical Significance: In this population of dogs with circulatory shock, the caudal vena cava to aorta ratio significantly increased after a fluid bolus. Future studies that implement blinding of the outcome assessors are warranted to confirm these findings.
5 October 2023 in Topics in Companion Animal Medicine
Intravenous lipid therapy (ILE) is used to treat neurotoxicosis in companion animals, but clinical evidence for in vivo xenobiotic partitioning and benefit remains limited. This study evaluated associations between the log n-octanol/water partition coefficient (log P), in vivo plasma partitioning, and early neurological outcome. In this case series from eight veterinary hospitals, dogs and cats with suspected neurotoxicosis received ILE. Blood collected before and at the end of infusion was separated into lipid and aqueous fractions and analyzed by gas chromatography–mass spectrometry. Log P values were retrieved from PubChem. Outcome (improvement vs. no-improvement) was the change from ILE-start to 4–6 h later. Thirty-four cases were analyzed (27 dogs and seven cats; 17 different xenobiotics were identified). At the end of infusion, xenobiotic lipid fraction concentrations exceeded aqueous concentrations in 28/34 cases, and log P did not correlate with the lipid-to-aqueous ratio. Improvement occurred in 14/34 animals and was associated with higher lipid-to-aqueous xenobiotic ratios (geometric mean ratio 5.7; 95% CI 1.73–19.05; p = 0.007). Overall, in vivo lipid sequestration was frequent and was associated with early neurological improvement, whereas log P alone did not predict partitioning or outcome.
Intravenous lipid therapy (ILE) is used to treat neurotoxicosis in companion animals, but clinical evidence for in vivo xenobiotic partitioning and benefit remains limited. This study evaluated associations between the log n-octanol/water partition coefficient (log P), in vivo plasma partitioning, and early neurological outcome. In a case series from eight veterinary hospitals, dogs and cats with suspected neurotoxicosis received ILE; blood collected before and at the end of infusion was separated into lipid and aqueous fractions and analyzed by gas chromatography-mass spectrometry. Log P values were retrieved from PubChem. Outcome (improved vs not improved) was the change from baseline to 4- 6 h after ILE start. Thirty-four cases were analyzed (27 dogs, 7 cats; 17 xenobiotics). At end of infusion, lipid-phase concentrations exceeded aqueous concentrations in 28/34 cases, and log P did not correlate with the lipid-to-aqueous ratio. Improvement occurred in 14/34 animals and was associated with higher lipid-to-aqueous xenobiotic ratios (geometric mean ratio 5.7; 95% CI 1.73–19.05; P = 0.007). Overall, in vivo lipid sequestration was frequent and related to early improvement, whereas log P alone did not predict partitioning or outcome.
L’échographie au chevet du patient et l’évaluation des variables dimensionnelles de la veine cave caudale pour évaluer le statut volémique chez le chien présentent un intérêt grandissant en médecine vétérinaire. A travers ce travail, nous décrivons un protocole de mesure échographique du rapport veine cave caudale (caudal vena cava (CVC)), sur aorte (CVC:Ao), permettant de s’affranchir de la variabilité de taille et de poids de nos patients. Nous avons tout d’abord établi dans ce travail un intervalle de référence de 0,93-1,32 pour le rapport CVC:Ao chez le chien sain. L’utilisation du rapport CVC:Ao est premièrement étudiée chez le chien présenté en insuffisance circulatoire. La valeur du rapport CVC:Ao est inférieure aux valeurs de référence décrites et augmente avec l’administration de solutés de perfusion. Ce rapport échographique semble avoir un intérêt dans la prise en charge diagnostique et thérapeutique de l’insuffisance circulatoire chez le chien. Le rapport CVC:Ao est ensuite étudié dans un groupe de chiens présentant une insuffisance rénale aiguë avec indication de prise en charge par une technique d’épuration extrarénale. Le rapport CVC:Ao n’est pas significativement augmenté chez les chiens présentant des signes de surcharge volémique. Le rapport CVC:Ao diminue de manière significative après séance d’épuration extra-rénale. Le rapport CVC:Ao semble cependant avoir un intérêt moindre dans l’évaluation des statuts hypervolémiques. Ces résultats invitent à la précaution, et devraient être confirmés par de futures études considérant le petit échantillon étudié ici. Ce rapport échographique est un indice de la macrocirculation. En état critique, l’incohérence hémodynamique entre la macro- et la microcirculation est d’une grande importance et peu étudiée en médecine vétérinaire. Ce travail permet également de valider la faisabilité de l'étude de la microcirculation avec le dispositif de caméra Sidestream Dark Field (SDF) dans la région sublinguale chez des chiens sains en vue d’étudier ultérieurement les altérations hémodynamiques systémiques et de perfusion d’organe dans différentes situations pathologiques.