HGMS is effective in separating or filtering fine and weakly magnetic particles and widely applied in mineral processing, water treatment, cell and protein purification. The magnetic matrix is a crucial device used in magnetic separator to generate high magnetic field gradient and provide surface sites for capturing magnetic particles. The material, geometry, size and arrangement of the matrix elements can significantly affect the gradient and distribution of the magnetic field, and the separating or filtrating performance. In this paper, the researches and developments of magnetic matrices used in HGMS are reviewed. Keywords: Magnetic matrix, HGMS, Revie
Using low density arrays of bistable magnetic nanowires as a model dipolar system, it is shown that the dipolar interaction field coefficient can be measured from the remanence curves as well as from other functions of the isothermal remanent magnetization and the DC demagnetization remanence obtained as an affine transformation of the Wohlfarth relation. Based on mean field arguments, these measurements are used to subtract and remove the contribution of the configuration dependent dipolar interaction field from the major loop and remanence curves. The corrected remanence curves are first used to obtain the intrinsic switching field distribution of the nanowire array and then to validate this approach showing that they yield results consistent with the Wohlfarth relation for an assembly of noninteracting particles, thus providing a self-consistent procedure to verify the measured values of the interaction field and its removal from the measurements.
First-order reversal curve diagrams, or FORC diagrams, have been studied to determine if the widths of their distributions along the interaction and coercivity axes can be related to the mean-field magnetization dependent interaction field (MDIF). Arrays of nanowires with diameters ranging from 18 up to 100 nm and packing fractions varying from 0.4 to 12% have been analyzed. The mean-field MDIF has been measured using the remanence curves and used as a measuring scale on the FORC diagrams. Based on these measurements, the full width of the interaction field distribution and the full width at half maximum (FWHM) of the FORC distribution profile along the interaction field direction are shown to be proportional to the MDIF, and the relation between them is found. Moreover, by interpreting the full width of the coercive field distribution in terms of the dipolar induced shearing, a simple relation is found between the width of this distribution and the MDIF. Furthermore, we show that the width of the FORC distribution along the coercive field axis is equal to the width of the switching field distribution obtained by the derivation of the DC remanence curve. This was further verified with the switching field distribution determined using in-field magnetic force microscopy (MFM) for very low density nanowires. The results are further supported by the good agreement found between the experiments and the values calculated using the mean-field model, which provides analytical expressions for both FORC distributions.
4 December 2013 in Journal of Physics: Condensed Matter
The dipolar interaction field in arrays of nickel nanotubes has been investigated on the basis of expressions derived from the effective demagnetizing field of the assembly as well as magnetometry measurements. The model incorporates explicitly the wall thickness and aspect ratio, as well as the spatial order of the nanotubes. The model and experiment show that the interaction field in nanotubes is smaller than that in solid nanowires due to the packing fraction reduction in tubes related to their inner cavity. Finally, good agreement between the model and experiment is found for the variation of the interaction field as a function of the tube wall thickness.