Wolfgang Fink

Prof. Dr. Wolfgang Fink

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
WJWilliam R. Johnson
William R. Johnson
DWDaniel W. Wilson
Daniel W. Wilson
WFWolfgang Fink
Wolfgang Fink
MHMark Humayun
Mark Humayun
GBGreg Bearman
Greg Bearman
Retinal imaging spectroscopy can provide functional maps using chromophore spectra. For example, oxygen saturation maps show ischemic areas from diabetes and venous occlusions. Obtaining retinal spatial-spectral data has been difficult due to saccades and long data acquisition times (>5s). We present a snapshot imaging spectrometer with far-reaching applicability that acquires a complete spatial-spectral image cube in ∼3ms from 450 to 700nm with 50 bands, eliminating motion artifacts and pixel misregistration. Current retinal spectral imaging approaches are incapable of true snapshot operation over a wide spectral range with a large number of spectral bands. Coupled to a fundus camera, the instrument returns true color retinal images for comparison to standard fundus images and for image validation while the patient is still dilated. Oxygen saturation maps were obtained with a three-wavelength algorithm: for healthy subjects arteries were ∼95% and veins 30 to 35% less. The instrument is now undergoing clinical trials.

1 December 2005 in Planetary and Space Science
Verified
Journal Article
Closed access
WFWolfgang Fink
Wolfgang Fink
JDJames M. Dohm
James M. Dohm
MTMark A. Tarbell
Mark A. Tarbell
THTrent M. Hare
Trent M. Hare
VBVictor R. Baker
Victor R. Baker

1 January 2004 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
WFWolfgang Fink
Wolfgang Fink
ASAlfredo A. Sadun
Alfredo A. Sadun
We describe a novel method for testing a visual field that employs a computer monitor with displays of varying contrast that permits unprecedented resolution and characterization of the structure of scotomas in three dimensions. Patients are placed in front of a touch-sensitive computer screen at a fixed distance. With one eye covered, they focus on a central fixation marker and trace with their finger the areas on an Amsler grid that are missing from their field of vision. Increasing degrees of contrast of the Amsler grid are simulated by repeating the test at different gray-scale levels. The results are recorded and then displayed as topographical contour rings by the computer test program. The results can also be rendered as an immediate 3-D depiction of the central hill-of-vision. Several clinical pilot studies have been conducted at the Doheny Eye Institute and more than 200 patients have been examined with this system so far. Conditions such as optic neuritis, anterior ischemic optic neuropathy (AION), age-related macular degeneration (AMD), glaucoma, and ocular hypertension have been successfully assessed by this test. Each condition provides unique patterns that are most evident in 3-D. The 3-D computer-automated threshold Amsler grid test is an innovative and noninvasive visual field test. It provides several advantages over state-of-the-art standard automated perimetry, including: (1) additional information through 3-D depiction of scotomas, such as location, extent, slope, depth, and shape; (2) high angular resolution (1 deg compared with typically 6 deg); (3) a simple test setup (merely a touch-sensitive computer monitor and the test software); (4) excellent patient compliance (spending 4 to 5 min per eye). In light of its promising initial tests, the 3-D visual field test appears to have the potential for the early detection and monitoring of various diseases over time. © 2004 Society of Photo-Optical Instrumentation Engineers.

1 January 2007
Verified
Conference Paper
Closed access
WFWolfgang Fink
Wolfgang Fink
JDJames M. Dohm
James M. Dohm
MTMark A. Tarbell
Mark A. Tarbell
THTrent M. Hare
Trent M. Hare
VBVictor R. Baker
Victor R. Baker
WMWilliam Mahaney
William Mahaney
A fundamentally new (scientific) reconnaissance mission concept, termed tier-scalable reconnaissance, for remote planetary (including Earth) atmospheric, surface and subsurface exploration recently has been devised that soon will replace the engineering and safety constrained mission designs of the past, allowing for optimal acquisition of geologic, paleohydrologic, paleoclimatic, and possible astrobiologic information of Venus, Mars, Europa, Ganymede, Titan, Enceladus, Triton, and other extraterrestrial targets. This paradigm is equally applicable to potentially hazardous or inaccessible operational areas on Earth such as those related to military or terrorist activities, or areas that have been exposed to biochemical agents, radiation, or natural disasters. Traditional missions have performed local, ground-level reconnaissance through rovers and immobile landers, or global mapping performed by an orbiter. The former is safety and engineering constrained, affording limited detailed reconnaissance of a single site at the expense of a regional understanding, while the latter returns immense datasets, often overlooking detailed information of local and regional significance.

15 May 2007 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
PNP. P Nazemi
P. P Nazemi
WFWolfgang Fink
Wolfgang Fink
ASA. A Sadun
A. A Sadun
BFB. Francis
B. Francis
DMD. Minckler
D. Minckler
Purpose: A recently devised 3D computer-automated threshold Amsler grid test was used to identify early and distinctive defects in people with suspected glaucoma. Further, the location, shape and depth of these field defects were characterised. Finally, the visual fields were compared with those obtained by standard automated perimetry. Patients and methods: Glaucoma suspects were defined as those having elevated intraocular pressure (>21 mm Hg) or cup-to-disc ratio of >0.5. 33 patients and 66 eyes with risk factors for glaucoma were examined. 15 patients and 23 eyes with no risk factors were tested as controls. The recently developed 3D computer-automated threshold Amsler grid test was used. The test exhibits a grid on a computer screen at a preselected greyscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. The 5-minute test required that the patients repeatedly outline scotomas on a touch screen with varied displays of contrast while maintaining their gaze on a central fixation marker. A 3D depiction of the visual field defects was then obtained that was further characterised by the location, shape and depth of the scotomas. The exam was repeated three times per eye. The results were compared to Humphrey visual field tests (ie, achromatic standard or SITA standard 30-2 or 24-2). Results: In this pilot study 79% of the eyes tested in the glaucoma-suspect group repeatedly demonstrated visual field loss with the 3D perimetry. The 3D depictions of visual field loss associated with these risk factors were all characteristic of or compatible with glaucoma. 71% of the eyes demonstrated arcuate defects or a nasal step. Constricted visual fields were shown in 29% of the eyes. No visual field changes were detected in the control group. Conclusions: The 3D computer-automated threshold Amsler grid test may demonstrate visual field abnormalities characteristic of glaucoma in glaucoma suspects with normal achromatic Humphrey visual field testing. This test may be used as a screening tool for the early detection of glaucoma.

1 January 2005 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
WFWolfgang Fink
Wolfgang Fink
Our purpose is to correct digital CCD-recorded Scheimpflug photographs, imaging both the anterior and posterior corneal surface, the anterior chamber, and the anterior eye lens surface for optical distortions. In a ray-tracing algorithm the imaging of the posterior corneal surface in a given Scheimpflug photograph is corrected by applying Snell’s law on parallel incident rays entering through the anterior corneal surface. Once the posterior corneal surface is corrected, the procedure is repeated, again with parallel incident rays entering through both the anterior and now corrected posterior corneal surface, to correct the imaging of the anterior eye lens surface. The refractive indices necessary for Snell’s law are taken from Gullstrand’s exact schematic eye model. Due to the optical/refractive correction, the digital Scheimpflug photograph decreases in size perpendicular to the direction of the optical axis. As a consequence the curvature radii of both the posterior corneal surface and the anterior lens surface are reduced significantly, as compared to the original digital Scheimpflug photograph. Furthermore, the corneal thickness and the anterior chamber depth are increased. The presented refractive correction method enables us to extract from Scheimpflug photographs the following quantities rather realistically: structure coordinates and curvature radii of both the posterior corneal surface and the anterior lens surface, corneal thickness, and anterior chamber depth. This method can readily be applied to other imaged quantities, such as the posterior eye lens surface, the lens thickness, and the pupillary opening. © 2005 Society of Photo-Optical Instrumentation Engineers.