Wide band gap materials such as silicon carbide and diamond are considered more suitable compared to silicon for the fabrication of piezoresistive pressure sensors for operation at high temperatures. We have carried out extensive FEM simulation study for theoretically assessing the response of pressure sensors incorporating these wide band gap materials. Response of sensors incorporating silicon micromachined diaphragm with oxide isolated piezoresistors of diamond or silicon carbide was studied using FEM simulations. The study was further extended for sensors incorporating diaphragm as well as piezoresistors of diamond or silicon carbide. The results in both cases were compared with those obtained for a single crystal or polycrystalline piezoresistor-based silicon pressure sensor. The results presented in this paper demonstrate that among the materials studied in this work, diamond-based sensors will have the least pressure sensitivity compared to silicon carbide or silicon-based sensors. However, considering the nonlinearity of response, diamond-based sensors will have the minimum nonlinearity of pressure response compared to silicon-based pressure sensors. Hence for the same nonlinearity, it would be possible to operate the diamond-based sensors up to much higher pressures.
We have carried out experimental investigation of the effect of gamma radiation on the performance of piezoresistive pressure sensors realized using different fabrication processes. These processes included standard diffused piezoresistor process, Silicon-On-Insulator (SOI) wafer based process and polysilicon piezoresistor based process. The pressure sensors were irradiated in a 60Co gamma chamber up to a total dose of 30 Mrad(Si). The sensors were characterized after different total dose exposures to measure the sensitivity, offset voltage and hysteresis. All three types of sensors did not show failure up to the studied dose of 30 Mrad(Si). The sensors fabricated using diffused piezoresistor based and polysilicon piezoresistor based processes showed insignificant change in the sensitivity. However, a significant change in the sensitivity (∼13%) and offset voltage (∼9 %) was observed for the SOI wafer based pressure sensor. The comparison of the gamma induced degradation of three types of sensors shows that the polysilicon piezoresistor based sensor has the best radiation hardness as it exhibits < 1% degradation of the sensitivity, offset voltage and hysteresis for gamma radiation exposure of 30 Mrad(Si).
This paper describes a technique for temperature sensitivity or thermal sag measurements of a geometric anti-spring based microelectromechanical system (MEMS) gravimeter (Wee-g). The Wee-g MEMS gravimeter is currently fabricated on a (100) silicon wafer using standard micro-nano fabrication techniques. The thermal behavior of silicon indicates that the Young’s modulus of silicon decreases with increase in temperature (∼64 ppm/K). This leads to a softening of the silicon material, resulting in the proof mass displacing (or sagging) under the influence of increasing temperature. It results in a change in the measured gravity, which is expressed as temperature sensitivity in terms of change in gravity per degree temperature. The temperature sensitivity for the silicon based MEMS gravimeter is found to be 60.14–64.87, 61.76, and 62.76 µGal/mK for experimental, finite element analysis (FEA) simulation, and analytical calculations, respectively. It suggests that the gravimeter's temperature sensitivity is dependent on the material properties used to fabricate the MEMS devices. In this paper, the experimental measurements of thermal sag are presented along with analytical calculations and simulations of the effect using FEA. The bespoke optical measurement system to quantify the thermal sag is also described. The results presented are an essential step toward the development of temperature insensitive MEMS gravimeters.