Yong-Jung Kim

Dr. Yong-Jung Kim

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2019 in IET Power Electronics
Verified
Journal Article
Closed access
YKYong-Jung Kim
Yong-Jung Kim
HKHyosung Kim
Hyosung Kim
As an essential part in technologies for energy storage systems (ESSs) or renewable energy systems (RESs), grid‐connected inverters need power passive filters to meet grid regulations. As typical passive filters, L filter and LCL filter are employed. Although LCL filter is more cost‐effective than L filter, a design of LCL filter is more complicated than L filter. LCL filter has three filter elements: inverter‐side inductor, grid‐side inductor, and filter capacitor. To design the three elements for LCL filter, three or more simultaneous equations should be required, which means that three or more design target should exist. Since conventional design methods for LCL filter do not suggest clear targets and do follow try & error method which cannot be matched exactly with design targets, the conventional methods cannot be optimal design. In this study, a filter inductance ratio to minimise total filter inductance, a filter admittance to meet grid regulation and characteristic impedance for low current stress of switch stack are suggested as design goals. Optimal design equation is proposed to meet the three design goals. The proposed method can solve unique filter elements for LCL filter without iterative try & error. The design method is evaluated through simulation and experiment.

20 September 2018 in Energies
Verified
Journal Article
Open access
PDF file
WKWooho Kim
Wooho Kim
YKYong-Jung Kim
Yong-Jung Kim
Hyosung KimHyosung Kim
Hyosung Kim
Recently, Low-Voltage DC (direct current) distribution systems have received high lights according to the expansion of DC generations and DC loads such as photovoltaics (PV) generations, electric vehicles (EVs), light emitting diodes (LEDs), computers, DC homes, etc. Low-Voltage DC distribution systems have optimistic perspectives since DC has various good aspects compared to alternating current (AC). However, ensuring safety of human and electric facility in Low-Voltage DC is not easy because of arc generation and difficulty of arc-extinguishing. This paper constructs a low-voltage DC circuit and studies the arc interruption that occurs when separating electrodes from where load currents flow. Also, arc extinguishers are experimented upon and analysed in various levels of source voltage and load currents conditions. Voltage and current characteristics for arc interruption are identified based on experimental results, and we establish the electric generation for arc interruption. Further, the voltage–current characteristics and the correlation of arc during arc duration time arc are verified, and the voltage–current equation and DC arc resistance model for the breaking arc are developed.

16 October 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YKYong-Jung Kim
Yong-Jung Kim
Hyosung KimHyosung Kim
Hyosung Kim
In electric distribution systems, a series arc occurs when a load and a power source are disconnected from a connector such as a circuit breaker, a socket-plug or a coupler. In DC systems, the arc is not extinguished unless the arc current decreases to zero. Sustaining plasma arc current can cause huge fire disasters. To cope with the arc faults in DC systems, the characteristics of the arc should be analyzed. However, a clear analysis method has not been suggested. This paper analyzes characteristics of a series-breaking arc in a DC circuit breaker in three operation phases; initiation, sustenance, and extinguishment. Based on the three operation characteristics, a series-breaking arc model is proposed and evaluated through experiment.

9 January 2019 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
YKYong-Jung Kim
Yong-Jung Kim
Hyosung KimHyosung Kim
Hyosung Kim

31 July 2023 in THE TRANSACTIONS OF KOREAN INSTITUTE OF POWER ELECTRONICS
Verified
Journal Article
Open access
YKYong-Jung Kim
Yong-Jung Kim
Hyosung KimHyosung Kim
Hyosung Kim
In AC power systems, the load current naturally reaches zero every half cycle, which results in a short-term spark that lasts less than a quarter cycle after the switch has been turned off or the plug has been removed from the socket. However, in DC power systems, the load current flows continuously without zero crossings, which causes the breaking arc to be prolonged and to develop easily into plasma, resulting in a high risk of arc accidents. Therefore, to ensure safety against breaking arcs in DC power systems, protective regulations must be established, and the physical properties of arc generation and extinction in DC power systems must be examined. This study aims to explore the experimental characteristics of breaking arcs in low-voltage DC systems that occur in normal brass electrodes, which are the main components of residential contact-type wall-mounted switches and socket-outlet plugs. This study analyzes the characteristics of breaking arcs between brass electrodes and presents a safe operation area for the arcs that is defined by the supply voltage and load power level. This study will enable nonexperts to use conventional brass electrode-based wall-mounted switches and socket-outlet plugs safely.