Deyu Hu

Deyu Hu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Regulatory Toxicology and Pharmacology
Verified
Journal Article
Closed access
SWShouyi Wang
Shouyi Wang
QZQingtao Zhang
Qingtao Zhang
YYYurong Yu
Yurong Yu
YCYa Chen
Ya Chen
SZSong Zeng
Song Zeng
DHDeyu Hu
Deyu Hu

17 June 2022 in Chemosphere
Verified
Journal Article
Closed access
WGWang Guo
Wang Guo
YYYa Yang
Ya Yang
XZXia Zhou
Xia Zhou
RMRenyue Ming
Renyue Ming
DHDeyu Hu
Deyu Hu
PLPing Lu
Ping Lu

23 January 2019 in Analytical Letters
Verified
Journal Article
Closed access
QZQingtao Zhang
Qingtao Zhang
YYYa Yang
Ya Yang
XLXiangwu Liu
Xiangwu Liu
YCYa Chen
Ya Chen
DHDeyu Hu
Deyu Hu
PLPing Lu
Ping Lu
An analytical method was established to simultaneously quantify flonicamid and its metabolites 4-trifluoromethylnicotinic acid (TFNA), N-(4-trifluoromethylnicotinoyl) glycine (TFNG), and 4-trifluoromethylnicotinamide (TFNA-AM) in tea using orthogonal experimental design and liquid chromatography–tandem mass spectrometry (LC–MS/MS). Residues were extracted from the samples with acetonitrile containing 1% acetic acid and were purified with graphitized carbon black. The linearity of the method was excellent in the concentration range of 0.01–10 µg/mL, producing correlation coefficients greater than 0.996 for the target compounds. The limits of detection and quantification of all analytes in tea were 0.0013–0.013 mg/kg and 0.004–0.040 mg/kg, respectively. The average recoveries of flonicamid, TFNA, TFNG, and TFNA-AM ranged from 75.14 to 92.72%, with intra- and interday relative standard deviations of 1.07–9.75%. The proposed method was successfully applied to the terminal residue determination of flonicamid and its metabolites in dry tea processed from three field trials’ fresh samples. The determined total terminal residue concentrations of flonicamid 10 days after the last application at all three sites were below the maximum residue limit (MRL) set by the European Union (0.1 mg/kg) and the residues in all samples were lower than the MRL established by the United States Environmental Protection Agency (EPA) (8 mg/kg). This method may be used to meet the requirements for the determination of flonicamid and its metabolites that could provide guidance for establishing a MRL for flonicamid in tea in China.

19 December 2017 in Biomedical Chromatography
Verified
Journal Article
Closed access
PDF file
QZQingtao Zhang
Qingtao Zhang
YCYuling Chen
Yuling Chen
SWShouyi Wang
Shouyi Wang
YYYurong Yu
Yurong Yu
PLPing Lu
Ping Lu
ZYZaihui Yang
Zaihui Yang

20 June 2023 in Aquatic Toxicology
Verified
Journal Article
Closed access
TFTianyou Feng
Tianyou Feng
LMLianhong Mou
Lianhong Mou
GOGuipeng Ou
Guipeng Ou
LLLing Liu
Ling Liu
YZYuping Zhang
Yuping Zhang
DHDeyu Hu
Deyu Hu

30 July 2019 in Food Additives & Contaminants: Part A
Verified
Journal Article
Closed access
XLXiangwu Liu
Xiangwu Liu
YYYa Yang
Ya Yang
YCYa Chen
Ya Chen
QZQingtao Zhang
Qingtao Zhang
PLPing Lu
Ping Lu
DHDeyu Hu
Deyu Hu
An efficient, sensitive, simple and fast method for the simultaneous determination of oxine-copper and pyraclostrobin in citrus fruit was developed and validated. The method uses ethylene diamine tetra-acetic acid as a competitive ligand to convert oxine-copper to soluble 8-hydroxyquinoline for analysis by QuEChERS and LC-MS/MS. Linear relationships were determined with correlation coefficients ranging from 0.9904 to 0.9998. The limits of detection for the analytes were 0.012–0.8 μg kg−1, and the limits of quantitation were 0.04–2.6 μg kg−1 in citrus. The average recoveries were 79.1–114.9% with relative standard deviations of less than 7.4%. The analyses of dissipation indicated that the half-lives of oxine-copper and pyraclostrobin were 1.94–3.67 and 1.79–2.48 days and the terminal residues were <0.08–8.99 and <0.02–1.90 mg kg−1, respectively. The risk quotients of oxine-copper and pyraclostrobin were 0.026–0.199 and 0.003–0.022, respectively. This risk assessment provides a reference for the safe and reasonable use of oxine-copper and pyraclostrobin and may help to establish maximum residue limits for these pesticides in China. GRAPHICAL ABSTRACT