This paper presents a summary of the key findings of the special issue of Atmosphere on Air Quality in New South Wales and discusses the implications of the work for policy makers and individuals. This special edition presents new air quality research in Australia undertaken by (or in association with) the Clean Air and Urban Landscapes hub, which is funded by the National Environmental Science Program on behalf of the Australian Government’s Department of the Environment and Energy. Air pollution in Australian cities is generally low, with typical concentrations of key pollutants at much lower levels than experienced in comparable cities in many other parts of the world. Australian cities do experience occasional exceedances in ozone and PM2.5 (above air pollution guidelines), as well as extreme pollution events, often as a result of bushfires, dust storms, or heatwaves. Even in the absence of extreme events, natural emissions play a significant role in influencing the Australian urban environment, due to the remoteness from large regional anthropogenic emission sources. By studying air quality in Australia, we can gain a greater understanding of the underlying atmospheric chemistry and health risks in less polluted atmospheric environments, and the health benefits of continued reduction in air pollution. These conditions may be representative of future air quality scenarios for parts of the Northern Hemisphere, as legislation and cleaner technologies reduce anthropogenic air pollution in European, American, and Asian cities. However, in many instances, current legislation regarding emissions in Australia is significantly more lax than in other developed countries, making Australia vulnerable to worsening air pollution in association with future population growth. The need to avoid complacency is highlighted by recent epidemiological research, reporting associations between air pollution and adverse health outcomes even at air pollutant concentrations that are lower than Australia’s national air quality standards. Improving air quality is expected to improve health outcomes at any pollution level, with specific benefits projected for reductions in long-term exposure to average PM2.5 concentrations.
We propose a new technique to prepare statistically-robust benchmarking data for evaluating chemical transport model meteorology and air quality parameters within the urban boundary layer. The approach employs atmospheric class-typing, using nocturnal radon measurements to assign atmospheric mixing classes, and can be applied temporally (across the diurnal cycle), or spatially (to create angular distributions of pollutants as a top-down constraint on emissions inventories). In this study only a short (<1-month) campaign is used, but grouping of the relative mixing classes based on nocturnal mean radon concentrations can be adjusted according to dataset length (i.e., number of days per category), or desired range of within-class variability. Calculating hourly distributions of observed and simulated values across diurnal composites of each class-type helps to: (i) bridge the gap between scales of simulation and observation, (ii) represent the variability associated with spatial and temporal heterogeneity of sources and meteorology without being confused by it, and (iii) provide an objective way to group results over whole diurnal cycles that separates ‘natural complicating factors’ (synoptic non-stationarity, rainfall, mesoscale motions, extreme stability, etc.) from problems related to parameterizations, or between-model differences. We demonstrate the utility of this technique using output from a suite of seven contemporary regional forecast and chemical transport models. Meteorological model skill varied across the diurnal cycle for all models, with an additional dependence on the atmospheric mixing class that varied between models. From an air quality perspective, model skill regarding the duration and magnitude of morning and evening “rush hour” pollution events varied strongly as a function of mixing class. Model skill was typically the lowest when public exposure would have been the highest, which has important implications for assessing potential health risks in new and rapidly evolving urban regions, and also for prioritizing the areas of model improvement for future applications.
The ability of meteorological models to accurately characterise regional meteorology plays a crucial role in the performance of photochemical simulations of air pollution. As part of the research funded by the Australian government’s Department of the Environment Clean Air and Urban Landscape hub, this study set out to complete an intercomparison of air quality models over the Sydney region. This intercomparison would test existing modelling capabilities, identify any problems and provide the necessary validation of models in the region. The first component of the intercomparison study was to assess the ability of the models to reproduce meteorological observations, since it is a significant driver of air quality. To evaluate the meteorological component of these air quality modelling systems, seven different simulations based on varying configurations of inputs, integrations and physical parameterizations of two meteorological models (the Weather Research and Forecasting (WRF) and Conformal Cubic Atmospheric Model (CCAM)) were examined. The modelling was conducted for three periods coinciding with comprehensive air quality measurement campaigns (the Sydney Particle Studies (SPS) 1 and 2 and the Measurement of Urban, Marine and Biogenic Air (MUMBA)). The analysis focuses on meteorological variables (temperature, mixing ratio of water, wind (via wind speed and zonal wind components), precipitation and planetary boundary layer height), that are relevant to air quality. The surface meteorology simulations were evaluated against observations from seven Bureau of Meteorology (BoM) Automatic Weather Stations through composite diurnal plots, Taylor plots and paired mean bias plots. Simulated vertical profiles of temperature, mixing ratio of water and wind (via wind speed and zonal wind components) were assessed through comparison with radiosonde data from the Sydney Airport BoM site. The statistical comparisons with observations identified systematic overestimations of wind speeds that were more pronounced overnight. The temperature was well simulated, with biases generally between ±2 °C and the largest biases seen overnight (up to 4 °C). The models tend to have a drier lower atmosphere than observed, implying that better representations of soil moisture and surface moisture fluxes would improve the subsequent air quality simulations. On average the models captured local-scale meteorological features, like the sea breeze, which is a critical feature driving ozone formation in the Sydney Basin. The overall performance and model biases were generally within the recommended benchmark values (e.g., ±1 °C mean bias in temperature, ±1 g/kg mean bias of water vapour mixing ratio and ±1.5 m s−1 mean bias of wind speed) except at either end of the scale, where the bias tends to be larger. The model biases reported here are similar to those seen in other model intercomparisons.
The coupled Conformal Cubic Atmospheric Model (CCAM) and Chemical Transport Model (CTM) (CCAM-CTM) was undertaken with eleven emission scenarios segregated from the 2008 New South Wales Greater Metropolitan Region (NSW GMR) Air Emission Inventory to predict major source contributions to ambient PM2.5 and exposure in the NSW GMR. Model results illustrate that populated areas in the NSW GMR are characterised with annual average PM2.5 of 6–7 µg/m3, while natural sources including biogenic emissions, sea salt and wind-blown dust contribute 2–4 µg/m3 to it. Summer and winter regional average PM2.5 ranges from 5.2–6.1 µg/m3 and 3.7–7.7 µg/m3 across Sydney East, Sydney Northwest, Sydney Southwest, Illawarra and Newcastle regions. Secondary inorganic aerosols (particulate nitrate, sulphate and ammonium) and sodium account for up to 23% and 18% of total PM2.5 mass in both summer and winter. The increase in elemental carbon (EC) mass from summer to winter is found across all regions but particularly remarkable in the Sydney East region. Among human-made sources, “wood heaters” is the first or second major source contributing to total PM2.5 and EC mass across Sydney in winter. “On-road mobile vehicles” is the top contributor to EC mass across regions, and it also has significant contributions to total PM2.5 mass, particulate nitrate and sulphate mass in the Sydney East region. “Power stations” is identified to be the third major contributor to the summer total PM2.5 mass across regions, and the first or second contributor to sulphate and ammonium mass in both summer and winter. “Non-road diesel and marine” plays a relatively important role in EC mass across regions except Illawarra. “Industry” is identified to be the first or second major contributor to sulphate and ammonium mass, and the second or third major contributor to total PM2.5 mass across regions. By multiplying modelled predictions with Australian Bureau of Statistics 1-km resolution gridded population data, the natural and human-made sources are found to contribute 60% (3.55 µg/m3) and 40% (2.41 µg/m3) to the population-weighted annual average PM2.5 (5.96 µg/m3). Major source groups “wood heaters”, “industry”, “on-road motor vehicles”, “power stations” and “non-road diesel and marine” accounts for 31%, 26%, 19%, 17% and 6% of the total human-made sources contribution, respectively. The results in this study enhance the quantitative understanding of major source contributions to ambient PM2.5 and its major chemical components. A greater understanding of the contribution of the major sources to PM2.5 exposures is the basis for air quality management interventions aiming to deliver improved public health outcomes.
Poor air quality is often associated with hot weather, but the quantitative attribution of high temperatures on air quality remains unclear. In this study, the effect of elevated temperatures on air quality is investigated in Greater Sydney using January 2013, a period of extreme heat during which temperatures at times exceeded 40 °C, as a case study. Using observations from 17 measurement sites and the Weather Research and Forecasting Chemistry (WRF-Chem) model, we analyse the effect of elevated temperatures on ozone in Sydney by running a number of sensitivity studies in which: (1) the model is run with biogenic emissions generated by MEGAN and separately run with monthly average Model of Emissions of Gases and Aerosols from Nature ( MEGAN) biogenic emissions (for January 2013); (2) the model results from the standard run are compared with those in which average temperatures (for January 2013) are only applied to the chemistry; (3) the model is run using both averaged biogenic emissions and temperatures; and (4 and 5) the model is run with half and zero biogenic emissions. The results show that the impact on simulated ozone through the effect of temperature on reaction rates is similar to the impact via the effect of temperature on biogenic emissions and the relative impacts are largely additive when compared to the run in which both are averaged. When averaged across 17 sites in Greater Sydney, the differences between ozone simulated under standard and averaged model conditions are as high as 16 ppbv. Removing biogenic emissions in the model has the effect of removing all simulated ozone episodes during extreme heat periods, highlighting the important role of biogenic emissions in Australia, where Eucalypts are a key biogenic source.
Accurate air quality modelling is an essential tool, both for strategic assessment (regulation development for emission controls) and for short-term forecasting (enabling warnings to be issued to protect vulnerable members of society when the pollution levels are predicted to be high). Model intercomparison studies are a valuable support to this work, being useful for identifying any issues with air quality models, and benchmarking their performance against international standards, thereby increasing confidence in their predictions. This paper presents the results of a comparison study of six chemical transport models which have been used to simulate short-term hourly to 24 hourly concentrations of fine particulate matter less than and equal to 2.5 µm in diameter (PM2.5) and ozone (O3) for Sydney, Australia. Model performance was evaluated by comparison to air quality measurements made at 16 locations for O3 and 5 locations for PM2.5, during three time periods that coincided with major atmospheric composition measurement campaigns in the region. These major campaigns included daytime measurements of PM2.5 composition, and so model performance for particulate sulfate (SO42−), nitrate (NO3−), ammonium (NH4+) and elemental carbon (EC) was evaluated at one site per modelling period. Domain-wide performance of the models for hourly O3 was good, with models meeting benchmark criteria and reproducing the observed O3 production regime (based on the O3/NOx indicator) at 80% or more of the sites. Nevertheless, model performance was worse at high (and low) O3 percentiles. Domain-wide model performance for 24 h average PM2.5 was more variable, with a general tendency for the models to under-predict PM2.5 concentrations during the summer and over-predict PM2.5 concentrations in the autumn. The modelling intercomparison exercise has led to improvements in the implementation of these models for Sydney and has increased confidence in their skill at reproducing observed atmospheric composition.