Chisako Muramatsu

Dr. Chisako Muramatsu


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Oral Radiology
Verified
Journal Article
Closed access
PDF file
CMChisako Muramatsu
Chisako Muramatsu
TMTakumi Morishita
Takumi Morishita
RTRyo Takahashi
Ryo Takahashi
THTatsuro Hayashi
Tatsuro Hayashi
WNWataru Nishiyama
Wataru Nishiyama
HFHiroshi Fujita
Hiroshi Fujita

1 September 2020 in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
Verified
Journal Article
Closed access
MFMotoki Fukuda
Motoki Fukuda
YAYoshiko Ariji
Yoshiko Ariji
YKYoshitaka Kise
Yoshitaka Kise
MNMichihito Nozawa
Michihito Nozawa
CKChiaki Kuwada
Chiaki Kuwada
EAEiichiro Ariji
Eiichiro Ariji

1 April 2020 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
CMChisako Muramatsu
Chisako Muramatsu
MNMizuho Nishio
Mizuho Nishio
TGTakuma Goto
Takuma Goto
MOMikinao Oiwa
Mikinao Oiwa
TMTakako Morita
Takako Morita
HFHiroshi Fujita
Hiroshi Fujita

1 January 2010 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
CMChisako Muramatsu
Chisako Muramatsu
YHYoshinori Hayashi
Yoshinori Hayashi
ASAkira Sawada
Akira Sawada
YHYuji Hatanaka
Yuji Hatanaka
THTakeshi Hara
Takeshi Hara
HFHiroshi Fujita
Hiroshi Fujita
Retinal nerve fiber layer defect (NFLD) is a major sign of glaucoma, which is the second leading cause of blindness in the world. Early detection of NFLDs is critical for improved prognosis of this progressive, blinding disease. We have investigated a computerized scheme for detection of NFLDs on retinal fundus images. In this study, 162 images, including 81 images with 99 NFLDs, were used. After major blood vessels were removed, the images were transformed so that the curved paths of retinal nerves become approximately straight on the basis of ellipses, and the Gabor filters were applied for enhancement of NFLDs. Bandlike regions darker than the surrounding pixels were detected as candidates of NFLDs. For each candidate, image features were determined and the likelihood of a true NFLD was determined by using the linear discriminant analysis and an artificial neural network (ANN). The sensitivity for detecting the NFLDs was 91% at 1.0 false positive per image by using the ANN. The proposed computerized system for the detection of NFLDs can be useful to physicians in the diagnosis of glaucoma in a mass screening.

1 January 2011 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
CMChisako Muramatsu
Chisako Muramatsu
TNToshiaki Nakagawa
Toshiaki Nakagawa
ASAkira Sawada
Akira Sawada
YHYuji Hatanaka
Yuji Hatanaka
TYTetsuya Yamamoto
Tetsuya Yamamoto
HFHiroshi Fujita
Hiroshi Fujita
Early diagnosis of glaucoma, which is the second leading cause of blindness in the world, can halt or slow the progression of the disease. We propose an automated method for analyzing the optic disc and measuring the cup-to-disc ratio (CDR) on stereo retinal fundus images to improve ophthalmologists’ diagnostic efficiency and potentially reduce the variation on the CDR measurement. The method was developed using 80 retinal fundus image pairs, including 25 glaucomatous, and 55 nonglaucomatous eyes, obtained at our institution. A disc region was segmented using the active contour method with the brightness and edge information. The segmentation of a cup region was performed using a depth map of the optic disc, which was reconstructed on the basis of the stereo disparity. The CDRs were measured and compared with those determined using the manual segmentation results by an expert ophthalmologist. The method was applied to a new database which consisted of 98 stereo image pairs including 60 and 30 pairs with and without signs of glaucoma, respectively. Using the CDRs, an area under the receiver operating characteristic curve of 0.90 was obtained for classification of the glaucomatous and nonglaucomatous eyes. The result indicates potential usefulness of the automated determination of CDRs for the diagnosis of glaucoma.