Ahmed Youssef

Prof. Dr. Ahmed Youssef

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2018 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
AYAhmed Youssef
Ahmed Youssef
AAAli Ahmed
Ali Ahmed
KMKoichi Maekawa
Koichi Maekawa
Current flexural and shear design methods for reinforced concrete members are mainly based upon the rectangular cross-sectional shape. A simplified new approach for designing circular cross sectional Reinforced Concrete (RC) members might be to convert them to equivalent area, square shapes. An experimental study was performed on reinforced concrete circular cross sections and equivalent area, rectangular cross sectional members. The RC members were tested under non linear monotonic loading conditions, under both flexural and shear controlled conditions. Furthermore, the 3D FEM package COM3D was used to simulate the nonlinear performance of circular and its equivalent area, square members. Experimental and analytical results show that the circular RC members and its equivalent square have similar nonlinear performance (load-deflection behavior) in both flexural and shear controlled failure conditions. A good agreement was found in nonlinear performance of main design criteria; initial stiffness, flexural capacity, and shear capacity of both types. Based upon these results, the proposed approach can be considered satisfactory.

30 November 2023 in Journal of Engineering and Applied Science
Verified
Journal Article
Open access
PDF file
AAAhmed Abdelaal
Ahmed Abdelaal
AYAhmed Youssef
Ahmed Youssef
Underground reinforced concrete (RC) structures, such as tunnels and pipelines, are frequently employed in urban areas and are designed to withstand both static and seismic loads, including those that occur during earthquakes. However, the inspection of deteriorated underground structures has yielded valuable findings for the civil engineering community, highlighting the need for further experimental investigation of the various damage mechanisms affecting RC tunnels under different loading conditions. This research presents a comprehensive experimental study aimed at elucidating the damage mechanisms of underground RC structures exposed to various loading conditions. Specifically, the study includes experimental testing of the corrosion of tunnel reinforcement and an investigation into the overall performance of corroded tunnels. The experimental results indicate that existing vertical loads significantly impact the lateral carrying capacity and ductility of RC tunnels.

1 November 2022 in Civil Engineering Journal
Verified
Journal Article
Open access
PDF file
SMShereen Mahmoud
Shereen Mahmoud
AYAhmed Youssef
Ahmed Youssef
HSHamed Salem
Hamed Salem
The nonlinear torsional behaviour of small-scale reinforced concrete (RC) beams with continuous staggered spiral as transverse reinforcement stirrups is experimentally investigated. Twelve miniatures RC beams were tested under torsion load considering the closed shape of stirrups and compared with continuous staggered spiral ones. All miniatures beams were scaled down to be one-eighth the prototype beam size. The main parameters considered in this research are stirrup spacing and its configurations. Small scale RC beams were taken into account in the existing study because of their construction simplicity and financial feasibility. Mortar without coarse aggregate was applied instead of concrete to reduce the size effect of applying small scale models. Ongoing research trials have been carried out to obtain an efficacious approach to boost torsion failure mechanisms because brittle torsion failure of RC structural elements should be avoided. This study emphasized boosted torsion capacity, dissipated energy, and helical crack propagation. During testing, the primary cracking torsion moment, ultimate torsion moment, peak twist angle, and failure mechanism of the beams were inspected. The use of spiral stirrups showed great enhancement of the torsional behaviour of samples. It was observed that using spiral stirrups rather than closed stirrups could result in a substantial increase in torsion capacity and dissipated energy of 87.7% and 89.8%, respectively. As a result, the predicted capacities of the RC beams prototype were estimated in detail, taking account the scale down factor implemented by the authors. Values obtained based on international specifications and guidelines were used to compare the experimental results. Doi: 10.28991/CEJ-2022-08-11-019 Full Text: PDF

9 October 2025 in Construction and Building Materials
Verified
Journal Article
Closed access
XHXiaoxu Huang
Xiaoxu Huang
ZHZichun Huang
Zichun Huang
YLYao Luan
Yao Luan
TWTiao Wang
Tiao Wang
YBYulei Bai
Yulei Bai
JEJanuarti Jaya Ekaputri
Januarti Jaya Ekaputri

5 June 2020 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
AYAhmed Youssef
Ahmed Youssef
AAaliahmed Ahmed
aliahmed Ahmed
KMKoichi Maekawa
Koichi Maekawa
This paper discusses performance of the reinforced concrete structures deteriorated by corrosion on basis of numerical simulation analysis. The purpose is to preliminarily investigate the idea of performance comparison of circular and square reinforced concrete columns under corroded conditions. Previous research carried out by the authors shows that equivalent area reinforced concrete (RC) columns exhibit similar load-displacement behavior under flexural and shear controlled conditions. The two types of columns deviate from this similarity after the corrosion of steel reinforcement present in the concrete. The change in the load-displacement behavior is highly dependent upon factors including the corrosion ratio, axial load, presence of web reinforcement etc., The experimentally verified 3D finite element modelling (FEM) program (COM3D) was used to investigate the seismic performance of the circular shaped and its equivalent area square shaped RC columns. The results show that the effect of mild corrosion (around 2% corrosion) on the load-displacement behavior of square RC columns is more significant as compared to circular RC columns at without axial load and at lesser main reinforcement ratio while a similar behavior or reverse trend is observed at higher main reinforcement ratios and for cases with 10% axial load. The effect of corrosion on the web reinforcement present in square columns is more pronounced as compared to circular columns at low main reinforcement ratios.

19 August 2024 in Journal of Engineering and Applied Science
Verified
Journal Article
Open access
PDF file
MYMohamed Yousry
Mohamed Yousry
HMHatem Mostafa
Hatem Mostafa
AYAhmed Youssef
Ahmed Youssef
The combination of concrete-filled steel tube (CFST) columns and reinforced concrete flat slabs provides a suitable structural solution that can be used to replace traditional structures in high-rise buildings. The connection between the CFST column and the RC flat slab is an important factor for this construction system to operate efficiently. In this study, a new form for the connection between the CFST column and the RC flat slab has been proposed. This connection has more constructability, where the steel tube is cut at the level of the slab to prevent the separation between the slab and the concrete inside the steel tube as the slab reinforcement is allowed to continue in the connection zone. The joint zone is strengthened with rebar rings to compensate for the loss in confinement caused by cutting the steel tube at the slab level. In addition to using longitudinal rebar in the joint zone to bear part of the vertical load and to ensure bending rigidity. The behavior of the proposed connection was investigated by testing three sets of small-sized samples. In addition, an equation based on the outcomes of the second set of tests has been carried out to determine the joint bearing capacity for the vertical load.